GE ZV850SPSS User Manual

Page 1
Chimney hoods—islands
Monogram
General features
Attractive design. Expertly crafted with uncompromising
attention to detail, a Monogram hood adds a striking architectural highlight to your kitchen.
Powerful ventilation. The variable-speed fan blower provides the power necessary to capture the smoke and fumes produced by high-performance cooking equipment.
Halogen lighting. Six levels of intensity are offered for different needs, from accent to ambient settings.
Removable filters. Filters can be easily detached from the hood for safe cleaning in your dishwasher.
Recirculating options. An optional vent hood kit for recirculating operation can be installed on the ZV850. Model ZV925 is designed to be vented outdoors or to recirculate into the room air.
For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com.
monogram.com
Chimney hoods
36" island vent hood
ZV850SPSS/ZV855SPSS
Overall dimensions (WxHxD in inches): 35-3/8 x 8-1/4 x 27-1/2
Amps @ 120VAC 2.7 Approx. shipping wt. (lbs.) 81
• 6" round exhaust duct
• Required duct covers must be
ordered separately
• Reversible duct cover for vented
or recirculating installation
36" island glass canopy vent hood
Overall dimensions (WxHxD in inches): 35-7/8 x 3-3/4 x 27-9/16
Amps @ 120VAC 4.6 Approx. shipping wt. (lbs.) 146
Professional hoodsCustom hood insertsTelescopic
• 8" round exhaust duct
• 8'–9' duct cover included
• Optional extension duct
covers available
• Reversible duct cover for
vented or recirculating installation
42" island vent hood
ZV1050SFSS
Overall dimensions (WxHxD in inches): 42 x 10 x 31-1/2
Amps @ 120VAC 6.7 Approx. shipping wt. (lbs.) 150
• Dual blowers
• 8" round exhaust duct
• 8' ceiling duct cover
included
• Optional extension duct covers available
51
downdraft vents
Page 2
Advance planning for chimney hoods—island
Stainless steel island hoods
Chimney vent hoods are available in 42" and 36" widths.
• Duct cover accessories to meet ceiling heights are required
for the ZV850 island hood. One accessory must be ordered with the vent hood.
• The ZV925, ZV850 and ZV855 vent hoods are supplied with a
two-piece decorative duct cover to reach an 8' to 9' ceiling. An optional duct cover accessory is available for 9'1" to 10'1" ceiling heights.
• The ZV1050 hood is supplied with a duct cover for an 8'
ceiling height (7'11" to 8'1"). Optional duct cover accessories are available for 9' and 10' ceiling heights.
• The installation height must be determined in advance for
island chimney hood models.
• All duct cover accessories must be ordered with the vent
hood and be on-site at the time of installation.
• Review the following chart to determine the appropriate
accessory duct cover.
Required duct cover accessories for vented installations
Ceiling height ZV850/ZV855 ZV925 ZV1050
8' Included Included Included Up to 9' Included Included ZX1059SFSS Up to 10' ZV8510SPSS ZX92510 ZX10510SFSS
Structural support
These vent hoods are heavy. Adequate structural support must be provided. Hoods must be secured to cross-framing positioned between ceiling joists.
• The vent hood and duct cover(s) must be on-site before final
framing and wall finishing. This will help to accurately locate the ductwork and electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop below.
• Mounting templates are provided with the installation
instructions to help accurately position the hood on the ceiling above the cooking surface.
Electrical requirements
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15- or 20-amp circuit breaker or time-delay fuse.
• The junction box is located on top of the hood. Route the
wiring as close to the installation as possible through the ceiling. Refer to the installation instructions for details.
Ductwork for ZV850/855SPSS
This vent hood must use 6" round duct.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• For satisfactory performance, duct run should not exceed
100 feet equivalent length for any duct configuration. Refer to the duct fittings chart in the installation instructions.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition needed in advance.
Ductwork for ZV925SLSS
This vent hood must use 8" round duct.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• For satisfactory performance, duct run should not exceed
100 feet equivalent length for any duct configuration. Refer to the duct fittings chart in the installation instructions.
Ductwork for ZV1050SFSS
This vent hood must use 8" round duct.
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• For satisfactory performance, duct run should not exceed
100 feet equivalent length for any duct configuration. Refer to the duct fittings chart in the installation instructions.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition needed in advance.
Recirculating installation
The ZV850/855 hood is designed to be vented to the outside, but it can easily be converted for recirculating operation.
Recirculating kits are included for the ZV850/855 hood. These kits include charcoal filters, a support frame with air deflector and a vented decorative duct cover to complete the installation. Kits are sized for ceiling height.
The ZV925SLSS is designed for either vented or recirculating operation. All necessary parts are included.
The ZV1050 is not convertible to recirculating operation.
52
Page 3
Advance planning for chimney hoods—island
*Height
to Ceiling
8-1/4"
35-3/8" (excluding utensil rods) 36-1/2" (including utensil rods)
27-1/2"
24" to 30"
36" Min.
9-7/16"
monogram.com
Product dimensions and clearances
This stainless steel hood can be installed over any Monogram® cooktop except Professional models. Accessories to meet
correct ceiling heights are required.
Model ZV850/855SPSS
* 50-1/8" for 10' ceiling using
ZX8510SPSS accessory
This vent hood must be installed 24" minimum to 30" maximum above the cooking surface; 25-1/2" is recommended to that the duct cover meets the ceiling. The cooking
surface
should be at least 36" above the floor.
A mounting template is provided with the installation instructions to help position the hood above the cooking surface and to locate the mounting brackets.
Charcoal filter replacements are available from your dealer or by calling 800.626.2002. Order catalog number WB02X10731.
ensure
Using duct cover accessories
A duct cover accessory is required for all ceiling heights.
Use this chart to determine the correct duct cover accessory for 8' to 10' ceilings that must be ordered with the hood.
ZV850/ZV855 installation heights
Ceiling height
7' 11" 24" 24" 8' 0" 24" to 25" 24" to 25" 8' 1" 24" to 26" 24" to 26" 8' 2" 24" to 27" 24" to 27" 8' 3" 24" to 28" 24" to 28" 8' 4" 27" to 29" 24" to 29" 8' 5" 28" to 30" 24" to 30" 8' 6" 29" to 30" 25" to 30" 8' 7" 30" 26" to 30" 8' 8" 27" to 30" 8' 9" 28" to 30" 8' 10" 29" to 30" 8' 11" 30" 8' 7" 24" 24" 8' 8" 24" to 25" 24" to 25" 8' 9" 24" to 26" 24" to 26" 8' 10" 24" to 27" 24" to 27" 8' 11" 24" to 28" 24" to 28" 9' 0" 24" to 29" 24" to 29" 9' 1" 24" to 30" 24" to 30" 9' 2" 24" to 30" 24" to 30" 9' 3" 24" to 30" 24" to 30" 9' 4" 24" to 30" 24" to 30" 9' 5" 24" to 30" 24" to 30" 9' 6" 24" to 30" 24" to 30" 9' 7" 24" to 30" 24" to 30" 9' 8" 25" to 30" 24" to 30" 9' 9" 26" to 30" 24" to 30" 9' 10" 27" to 30" 25" to 30" 9' 11" 28" to 30" 25" to 30" 10' 0" 29" to 30" 26" to 30" 10' 1" 30" 27" to 30" 10' 2" 28" to 30" 10' 3" 29" to 30" 10' 4" 30"
*Based on 36" countertop height.
Possible vented installation height*
Possible recirculating installation height
Lower fra me 20-3/4"
Lower fra me 20-3/4"
Lower duc t 18"
Upper duc t 18"
Upper fra me 31"
Supplied lower frame
Supplied duct covers
Supplied frame
ZX8510SPSS – accessory upper frame
Duct Cover Dimensions ZX8510SPSS Duct Cover
Accessory
This accessory is available for installation with ceiling heights above 8'7" to 10' and higher.
20-3/4"
15-3/4"
20-3/4"
Supplied duct cover
This accessory consists of two 26-1/4" duct covers and a 31" upper support frame piece.
Chimney hoods
Lower duc t 26-1/4"
Upper duc t 26-1/4"
Professional hoodsCustom hood insertsTelescopic
ZX8510SPSS – accessory duct covers
downdraft vents
The serial plate is located behind the removable filters.
53
Page 4
Advance planning for chimney hoods—island
23-1/4"
2-3/4"
27-9/16"
35-7/8"
*Height
to
Ceiling
Product dimensions and clearances
This glass canopy hood can be installed over any Monogram® cooktop (except Professional models).
Model ZV925SLSS
* The supplied duct
cover is sized to fit 8' to 9' ceiling heights. For 9'1" to 10'1" ceilings, order ZX92510.
NOTE: Measure installation height from the cooking surface to the outer glass portion of the hood.
24" Min. 30" Max.
36" Min.
• This hood must be installed 24" minimum to 30" maximum
above the cooking surface. The cooking surface should be at least 36" above the floor.
Important
• The hood installation height depends on the ceiling height. Use the chart shown to determine the EXACT installation height.
• Duct cover side trim pieces are provided and must be used
to cover installation screws. They are sized to fit the specific installation heights shown in the chart.
• This hood can be installed for recirculating operation. No kits required.
A mounting template is provided with the installation instructions to help position the hood above the cooking surface and to locate the mounting brackets.
ZV925SLSS duct cover dimensions
14"
Side Trim
Determine installation height
Use this chart to accurately determine installation height, depending on your ceiling height.
ZV925 installation heights
Possible ceiling height
7' 11" 25" 30-1/2" 8' 0" 27" 30-1/2" 8' 1" 24" 34-1/2" 8' 1" 28" 30-1/2" 8' 2" 25" 34-1/2" 8' 2" 29" 30-1/2" 8' 3" 26" 34-1/2" 8' 3" 30" 30-1/2" 8' 4" 27" 34-1/2" 8' 5" 24" 38-1/2" 8' 5" 28" 34-1/2" 8' 6" 25" 38-1/2" 8' 6" 29" 34-1/2" 8' 7" 26" 38-1/2" 8' 7" 30" 34-1/2" 8' 8" 27" 38-1/2" 8' 9" 24" 42-1/2" 8' 9" 28" 38-1/2" 8' 10" 25" 42-1/2" 8' 10" 29" 38-1/2" 8' 11" 26" 42-1/2" 8' 11" 30" 38-1/2" 9' 0" 27" 42-1/2" 9' 1" 24" 46-1/2" 9' 1" 28" 42-1/2" 9' 2" 25" 46-1/2" 9' 2" 29" 42-1/2" 9' 3" 26" 46-1/2" 9' 3" 30" 42-1/2" 9' 4" 27" 46-1/2" 9' 5" 24" 50-1/2" 9' 5" 28" 46-1/2" 9' 6" 25" 50-1/2" 9' 6" 29" 46-1/2" 9' 7" 26" 50-1/2" 9' 7" 30" 46-1/2" 9' 8" 27" 50-1/2" 9' 9" 24" 54-1/2" 9' 9" 28" 50-1/2" 9' 10" 25" 54-1/2" 9' 10" 29" 50-1/2" 9' 11" 26" 54-1/2" 9' 11" 30" 50-1/2" 10' 0" 27" 54-1/2" 10' 1" 28" 54-1/2"
*Based on 36" countertop height.
Hood installation height*
Mounting frame height
Duct cover accessory
Supplied duct covers
Accessory ZX92510
Side Trim
NOTE: ZX92510 accessory consists of one 36-3/4"-long duct cover.
24-3/4"
12-3/16"
54
The serial plate is located behind the removable filters.
Charcoal filter replacements are available from your dealer or by calling 800.626.2002. Order catalog number WB02X11284.
Page 5
Advance planning for chimney hoods—island
10"
*Height to Ceiling
42"
31-1/2"
*30"
Recommended
36" Min.
monogram.com
Product dimensions and clearances
This stainless steel hood can be installed over any 30" or 36" Monogram cooktop or range, including professional models.
Model ZV1050SFSS
* 20" for 8' ceiling using
supplied duct cover
32" for 9' ceiling using
ZX1059SFSS accessory
44" for 10' ceiling using
ZX10510SFSS accessory
This vent hood is supplied with a decorative duct cover to reach 8' ceiling height, or between 7'11" and 8'1".
*9' to 10' ceilings may be 25-1/2" to 30" clearance.
Using duct cover accessories
A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine the need for a duct cover accessory.
ZV10S0SFSS installation heights
Ac tual ceiling height
7' 11" 29" 8' 0" 30" 8' 1" 30" 8' 2" 25-1/2" to 30" 8' 3" 25-1/2" to 30" 8' 3" 25-1/2" to 30" 8' 4" 25-1/2" to 30" 8' 5" 25-1/2" to 30" 8' 6" 25-1/2" to 30" 8' 7" 25-1/2" to 30" 8' 8" 25-1/2" to 30" 8' 9" 25-1/2" to 30" 8' 10" 25-1/2" to 30" 9' 0" 25-1/2" to 30" 9' 1" 25-1/2" to 30" 9' 2" 25-1/2" to 30" 9' 3" 25-1/2" to 30" 9' 4" 25-1/2" to 30" 9' 5" 25-1/2" to 30" 9' 6" 25-1/2" to 30" 9' 6" 25-1/2" to 30" 9' 7" 25-1/2" to 30" 9' 8" 25-1/2" to 30" 9' 9" 25-1/2" to 30" 9' 10" 25-1/2" to 30" 9' 11" 25-1/2" to 30" 10' 0" 25-1/2" to 30"
*Based on 36" countertop height.
Possible hood installation height*
Duct cover accessory
Supplied
Accessory ZX1059SFSS
Accessory ZX10510SFSS
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
This vent hood must be installed 25-1/2" minimum to 30" max
imum above the cooking surface.
The distance between the cooking surface and the bottom of the hood must be at least 25-1/2". The 30" recommended installation height above the standard 36" countertop cover fit to the ceiling. For 9' and 10'
will ensure duct
ceiling heights, the hood
may be lowered to 25-1/2" over the cooking surface.
• When installing this island hood above a Monogram
professional range or rangetop, installation clearance must be at least 30".
A mounting template is provided with the installation instructions to help position the hood above the cooking surface and to locate the mounting brackets.
Important: Clearances may vary due to type of cooking product and local codes. Check with local inspectors to be sure the standard is applicable.
ZV1050 duct cover dimensions
Accessory A B
Supplied
ZX1059SFSS
ZX10510SFSS
11-1/2" 12"
19" 20"
25" 26"
The serial plate is located behind the removable filters.
10-3/4"
16"
downdraft vents
55
Page 6
Pairing hoods with cooking equipment
Monogram® hoods are designed to perfectly coordinate with Monogram ranges and cooktops. To learn which cooking products can be combined with the hood you have selected, refer to the charts below.
Wall-mounted Island Downdraft
Installation combinations
Style
Width
High speed blower rating
Sones working speed
Recirculating option
Vented duct cover options
Duct size
Equivalent duct length
ZV755SPSS ZV750SPSS ZV800SJSS ZV830SMSS ZV900SLSS ZV950SDSS
All non-pro cooktops
Chimney
36" 36" 30" 36" 36" 36" 42" 36" 36"/30 "
490 CFM 350 CFM 460 CFM 420 CFM 490 CFM 690 CFM
10.0, 6.0 210/2.0, 170/1.1
8'–10' 8" options 8'–10' options 8'–12' options 8'–10' 5" options No 8'–10' 4" options No 8'–10' 1" options No
8' to 9' 2" duct cover included; 9" to 10' 3" duct cover optional
6" round 6" round 8" round 8" round 8" round 6" round 8" round 8" round 3-1/4" x 10" rect.
100' 100' 100' 10 0' 100' 100' 100 ' 10 0' 100'
All non-pro cooktops
Chimney (slide-out) Chimney Chimney Chimney Chimney Chimney Chimney
7.0 220/2.0
8' to 10' duct cover included; or undercabinet option
All 30" non-pro cooktops
9.0 190/2.0
7'11" to 10' duct cover included; 10' to 12' duc t cover optional
All non-pro cooktops
8.0 230/2.0
8' to 9' 5" duc t cover included; 9' 6" to 10' 5" duct cover optional
All 30" and 36" cooktops and ranges
6.0 330/1.3
8', 9' or 10' duct cover included; 10' to 14' duct cover optional
ZV855SPSS ZV850SPSS ZV1050SFSS ZV925SLSS
All non-pro cooktops
490 CFM 350 CFM 10 40 CFM 490 CFM
10.0, 6.0 210/2.0, 170/1.1
8' to 8' 7" duct cover included; 9' to 10' 1" duct cover optional
All 30" and 36" cooktops and ranges
10.0 450/2.5
8'1" duct cover included, 8'2 " or 10' duct cover optional
All non-pro cooktops
8.0 230/2.0
8' to 9' duct cover included; 9' 1" to 10' 1" duct cover optional
ZVB36STSS ZVB30STSS
All non-pro cooktops
Telescopic downdraft
390 CFM
10.5 170/2.5
Indoor remote blower option
Professional wall-mounted Professional island Wall or island hood inser ts ZV48TSFSS
ZV36TSFSS
Installation combinations
Style
Width
Blower rating
Sones working speed
Recirculating option
Vented duct cover options
Duct size
Equivalent duct length
42
Note: Cooktop or range not to exceed vent hood width
ZV30TSFSS
All Monogram cooktops and ranges
Tapere d Straight Restaurant
48"/36"/30" 48"/36"/30" 48"/ 36"/30" 30" 42" 54" 36"/30" 48"/42"
1090/620/620 CFM
13.0, 9.0 430/2.5 240/1.1
No No No Yes No No No No
Optional 6" and 12" duct covers; stackable
10" round 10" round 10" round 8" round 10" round 10" round 8" round 8" round
150' 150' 150' 100' 150' 150' 100' 100'
ZV48SSFSS ZV36SSFSS ZV30SSFSS
All Monogram cooktops and ranges
1090/620/620 CFM
13.0, 9.0 430/2.5 240/1.1
Optional 6" and 12" duct covers, standard or full-width; stackable
ZV48RSFSS ZV36RSFSS ZV30RSFSS ZV30HSRSS ZV42ISHS S ZV54ISHSS
All Monogram cooktops and ranges
1090/620/620 CFM 530 CFM 1090 CFM 1090 CFM 640 CFM 1140 CFM
13.0, 9.0 430/2.5 240/1.1
Optional 6" and 12" duct covers, standard or full-width; stackable
All Monogram 30" cooktops and ranges
Wall-mounted/ undercabinet Tap ered Ta pere d Insert Insert
9.0 240/2.0
3-1/2 risers with and without louvers included
All 30" and 36" cooktops
13.0 430/2.5
7'11" to 8'5" duct cover included, 8'6" to 10'4" duct cover optional
All Monogram cooktops and ranges
13.0 430/2.5
7'11" to 8'5" duct cover included, 8'6" to 10'4" duct cover optional N /A N/A
ZVC36LSS ZVC30LSS
All 30" and 36" cooktops and ranges
14.0 250/3.5
ZVC48LSS ZVC42LSS
All Monogram cooktops and ranges
16.5 490/4.0
Page 7
The Home Ventilating Institute (HVI) is a third-party certification organization focused on providing a fair and credible method of comparing ventilation performance of similar products. Many agencies such as ENERGY STAR
®
and ASHRAE utilize HVI certification for performance assurance. All Monogram ventilation products are certified by HVI.
Some key performance criteria measured by HVI are sound level measured in sones, high speed and working speed measured in cubic feet per minute (cfm).
A sone is an internationally recognized measurement of sound output. Sones translate decibel ratings into numbers that correspond to the way people sense loudness. The lower the sone number the quieter the sound.
Working speed is defined as the speed that produces 100 cfm, or the lowest speed above 100 cfm that a hood can produce, when working on the same duct system as the maximum speed.
(HVI916, March 1, 2009) (http://hvi.org/faqs.html)
monogram.com
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
43
Loading...