Before you begin - Read these instructions completely and careflllly.
IMPORTANT - Save these instructions for local inspector's use.
IMPORTANT - OBSERVE AI,L GOVERNING (;ODES AND ORDINANCES.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions with your Owner's Manual for flmne reference.
WARNING: This appliance must be properly grounded. See "Electrical Supply," page 5.
If you have a question concerning the
installation of this product, call the GE Answer
Center ®Consumer Information Service at
800.626.2000, 24 hours a day, 7 days a week.
If you received a damaged vent hood, you
should immediately contact your dealer or
builder.
For Monogram local service in your area,
1.800.444.1845.
For Monogram service in Canada, call
1.888.880.3030.
For Monogram Parts and Accessories, call
1.800.626.2002.
(;cAUTION!
Due to the weight and size of this vent hood
and to reduce the risk of personal i_jury or
damage to the product, TWO PEOPI,E ARE
REO,.UIRED FOR PROPER INSTAI,I,ATION.
Proper installation is the responsibility of
the installer. Product failure due to improper
installation is not covered under the GE
Appliance _¥arranty. See the Owner's
Manual for warranty information.
_i_SkRNING:
To reduce the risk of fire or elecuical
shock, do not use this hood with any external
solid-state speed conuol device. Any such
alteration flom original factory wiring could
result in damage to the unit and/or create
an elecuical safety hazard.
To reduce the risk of fire and to properly
exhaust air, be sure to duct air outdoors. Do
not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces or garages.
_i_SkRNING: TO REDUCE THE RISK OF FIRE,
USE ONIX METAl, DUCTWORK
TO REDUCE THE RISK OF FIRE,
EI,ECTRICAI, SHOCK OR INJURY TO
PERSONS, OBSERVE THE FOI,I,OWING:
A. Use this unit only in the manner intended
by the manufactureL If you have any
questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch
power off at the service panel and lock service
panel to prevent power flom being switched
on accidentally. If the service panel cannot be
locked, fasten a tag or prominent warning
label to the panel.
For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
or vapors.
Structural flaming, installation work and
elecuical wiring must be done by qualified
person (s), in accordance with all applicable
codes and standards including fire-rated
construction.
Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of tirol burning equipment to
prevent back drafting. Follow the heating
equipment manufacturer's guidelines and
safety standards such as those published by
the National Fire Protection Association
(NFPA), and the American Society for
Heating, Refligerafion and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
I,ocal codes vary. Installation elecuical
connections and grounding must comply
with applicable codes. In the absence of
local codes, the vent should be installed in
accordance with National Electrical (;ode
ANSI/NFPA 70-1990 or latest edition.
Contents
Model Available ............................................ 3
Required Accessory ...................................... 3
Recirculating Operation .............................. 3
Product Dimensions ..................................... 3
Using Duct Cover Accessories ..................... 4
Installation Preparation
Tools and Materials Required ..................... 5
Power Supply ................................................ 5
Duct Fittings ................................................. 6
Step 1, Advance Planning ........................ 7, 8
Installation
Step 2, Remove the Packaging .................... 9
Step 3, Check Installation Hardware .......... 9
Step 4, Mount Template ............................ 10
Step 5, Install Support Frame .................... 10
Step 6, Secure Wiring ................................ 11
Step 7, Size and Install Ductwork .............. 11
Step 8, Install Decorative Duct Covers ..... 12
Step 9, Install Hood ................................... 13
Step 10, Connect Electrical ....................... 13
Step 11, Slide Duct Cover Down,
Install Side Utility Bars ................ 14
Step 12, Install Filters ................................. 15
Step 1,3,Finalize Installation ..................... 15
Design Intormation
36" Island Vent Hood
Model
Available
Required
Aeeesso U
Reeireulating
Operation
Product
Dimensions
Model This vent hood is designed to
ZV850 be used in vented ceiling mounted
installations.
ZX858 - Fox 8 ft. ceiling height.
This kit includes decorative duct covers and
support flames to reach an 8 ft ceiling height.
ZX859 - Fox 9 ft. ceiling height.
This kit includes decorative duct covers and
support flames to reach an 9 ft ceiling height.
This hood may be installed for recirculadng
operation. One of the following kits is
required and must be ordered with the hood.
ZXR858 - For 8 ft. ceiling height.
ZXR859 - For 9 ft. ceiling height.
ZXR8510 - For 10 ft. ceiling height.
The vent hood must be installed 24" rain. and
30" max. above the cooking surface. 25-1/2" is
recommended for best venting performance
and to insure that the duct cover meets the
ceiling. The cooking surface should be at least
36" above the floor. Installation will be easier if
the vent hood is installed before the cooktop
and countertop is installed.
NOTE: Accessories to meet proper
ceiling height are required to complete
the installation.
ZX8510 - Fox 10 ft. ceiling height.
This kit includes decorative duct covers and
support flames to reach a 10 ft. ceiling height.
Order the required accessox y at the same time
as the vent hood and have on site before
installation.
Both the hood and accessory must be
on site at the time of installation. Follow
the installation insuuctions packed with
the accessory to complete the installation.
*He ght
] toCeiling
"25-1/2" Recommended
36"Reference
*26-1/4"for8ft. Ceiling
UsingZX858Accessory
38-1/8"for9 ft. Ceiling
UsingZX859Accessory
50-1/8"for10ft.Ceiling
UsingZX8510Accessory
Thedistance between the cooking surface and the bottom
of the hood must be at least24" and upto 30". The 25-1/2"
recommendedinstallation height, abovethe standard36"
countertop,will insure duct coverfit to the ceiling.
Design Intormation
36" Island Vent Hood
Usinff Duct
Cover Accessories
A duct cover accessory is required for all
ceiling heights. Use this chart to determine the
correct Duct Cover Accessory for 8 ft. to 10 ft.
ceilings that must be ordered with the hood.
ZV850SBInstallation Heights
Actual
Ceiling * PossibleHood
Height Installation Height
7' 11" 24-1/2"
8'0" 25-1/2"
8' 1" 25-1/2"t0 26-1/2"
8' 2" 25-1/2"t0 27-1/2"
8' 3" 25-1/2" t0 28-1/2"
8' 4" 25-1/2" t0 29-1/2"
8' 5" 30" max.
8' 6" 30" max.
8' 7" 30" max.
8' 8" 30" max.
8' 9" 30" max.
8' 10" 30" max.
8' 11" 30" max.
9' O" 30" max.
9' 1" 30" max.
9' 2" 30" max.
9' 3" 30" max.
9' 4" 30" max.
9' 5" 30" max.
9' 6" 30" max.
9' 7" 30" max.
9' 8" 30" max.
9' 9" 30" max.
9' 10" 30" max.
9' 11" 30" max.
10'O" 30" max.
DuctCover
Accessory
>-
o o3
co
co
IJJ ¢o
oX
_.3 N
m
C.0
O3
C0
x
N
>-
et-
o
uJ
<_
m
Lg3
O3
x
N
>-
n-
o
o3
o3
uJ
co
co
<_
ZV850 Duct Cover Dimensions
Vented
Installation A
ZX858SB 14-3/16"
ZX859SB 20-1/2"
ZX8510SB 26"
B ,
15-3/16"
22-1/2"
27-1/2"
9-7/16" .
15-3/4"
j-
* Based on36" countertop height.
Installation Preparation
36" Island Vent Hood
7bols and
Materials
Required
(not supplied)
• Tapemeasure
• Knife
• Spirit level
• Wire cutter
• Wire stripper
• Wire nuts
• Electric drill and 5/32" bit
• Phillips screwdriver
• Flat blade screwdriver
• Hammer
• Pliers
• 10 mmHexwrench/socket
• Safety glasses
• Tapeto mounttemplate
• Glovesto protectagainst sharp edges
IMPORTANT- (Please read careflflly)
FOR PERSONAI, SAFETY, THIS
APPI,IANCE MUST BE PROPERIX
(;ROUNDED.
Remove house flase or open circuit
breaker before beginning
installation.
Do not use an extension cord or adapter
plug with this appliance. Follow National
Elecuical Code or prevailing local codes
and ordinances.
• 120V60Hz.15or20 Amp, 2wire with ground.
Properlygroundedbranchcircuit.
• Strain relief for junction box cover.
• Plumb
• Center punch
Grounding Instructions
The grounding conductor must be connected
to a ground metal, permanent wiring system,
or an equipment-grounding terminal or lead
on the hood.
Electrical supply
This vent hood must be supplied with 120V,
60Hz, and connected to an individual,
properly grounded branch circuit, and
protected by a 15 or 20 amp circuit
breaker or time delay flase.
• Wiring must be 2 wire with ground.
• If the elecuical supply does not meet
tim above requirements, call a licensed
elecuician before proceeding.
• Rotate house wiring in the ceiling, as
close to the installation location as possible.
Allow an additional 3 feet length flom
ceiling joists to reach the junction box
on the hood.
• Connect the wiring to the house wiring in
accordance with local codes.
Warning: The improper
connection of the equipment-
grounding conductor can result in
a risk of elecuic shock. Check with
a qualified elecuician or service
representative if you are in doubt whether
the appliance is properly grounded.