Chimney hoods—wall-mount
General features
Attractive design. Expertly crafted with uncompromising
attention to detail, a Monogram
architectural highlight to your kitchen.
Powerful ventilation. The variable-speed fan blower provides
the power necessary to capture the smoke and fumes
produced by high-performance cooking equipment.
Halogen lighting. Six levels of intensity are offered for
different needs, from accent to ambient settings.
Removable filters. Filters can be easily detached from
the hood for safe cleaning in your dishwasher.
Recirculating options for ZV750/755.
These hoods may be installed for vented or recirculating
operation. All necessary parts are included. No kits required.
ZV800, ZV830 and ZV900 models are designed to be vented
outdoors or to recirculate into the room air. (Air deflector,
charcoal filter and a reversible duct cover are packed with
models ZV800, ZV830 and ZV900.)
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
®
hood adds a striking
36" wall-mount glass
canopy hood
ZV900SLSS
Overall dimensions
(WxHxD in inches):
35-7/8 x 3-1/4 x 20-7/16
Amps @ 120VAC 4.3
Approx. shipping wt. (lbs.) 123
•
8" round exhaust duct
•
8'–9'5" ceiling duct
cover included
•
Optional extension duct
covers available
•
Reversible duct cover for
36" wall-mount
vent hood
ZV950SDSS
Overall dimensions
(WxHxD in inches):
35-5/8 x 10 x 25
Amps @ 120VAC 4.5
Approx. shipping wt. (lbs.) 110
•
Dual blowers
•
8" round exhaust duct
•
8'–10' ceiling duct cover
included
•
Optional extension
duct covers available
vented or recirculating
installations.
30" wall-mount
vent hood
36" wall-mount
vent hood
36" wall-mount hood
with retractable
glass canopy
ZV830SMSS
Overall dimensions
(WxHxD in inches):
29-7/8 x 5-7/8 x 18-7/8
Amps @ 120VAC 4.6
Approx. shipping wt. (lbs.) 81
•
8" round exhaust duct
•
8'–10' ceiling duct
cover included
•
Optional extension duct cover
available
•
Reversible duct cover for
vented or recirculating
installations
44
ZV750SPSS
ZV755SPSS
Overall dimensions
(WxHxD in inches):
34-5/8 x 8-1/4 x 21-5/8
Amps @ 120VAC 3.7
Approx. shipping wt. (lbs.) 81
•
6" round exhaust duct
•
8'–9' ceiling duct cover
included
•
Optional extension duct
cover available
•
Reversible duct cover for
vented or recirculating
installations
ZV800SJSS
Overall dimensions
(WxHxD in inches):
36 x 1-1/2 x 18-15/16
(with hood extended)
Amps @ 120VAC 3.3
Approx. shipping wt. (lbs.) 100
•
6" round exhaust duct
•
8'–10' ceiling duct cover
included
•
Reversible duct cover for
vented or recirculating
installations
Advance planning for chimney hoods—wall-mount
monogram.com
Wall-mount hoods
Chimney vent hoods are available in 30" and 36" widths. All
models are supplied with a two-piece stainless steel duct cover
to conceal the ductwork running from the top of the hood to
the ceiling.
• The installation height should be determined in advance.
If necessary, accessories for height adjustment should be
ordered with the vent hood and be on-site at the time of
installation.
• Review the following chart to determine the need for an
accessory duct cover.
Duct cover accessories for vented installations
Ceiling
height
8' Included Included Included Included up to 9'5"
Up to 9' Included Included Included Included up to 9'5"
Up to 10' Included ZX7510SPSS Included Included ZX90010*
10' to 12' ZX83012 — — — —
10' to 14' — — ZX14SDSS — —
*ZX90010 for 9'6" up to 10'5"
ZV830 ZV750/
755
ZV950 ZV800 ZV900
Structural support
These vent hoods are heavy. Adequate structural support
must be provided. Hoods must be secured to vertical studs
in the wall or to horizontal supports.
• It is strongly recommended that the vent hood and duct
cover(s) if used, be on-site before final framing and wall
finishing. This will help to accurately locate the ductwork
and electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop below.
• Mounting templates are provided with the installation
instructions to help accurately position the hood above the
cooking surface.
Electrical requirements
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15- or 20-amp circuit breaker or time-delay fuse.
Ductwork planning
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
Ductwork for ZV830SMSS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 10' ceiling. ZX83012 can be
ordered to reach 10' to 12' ceiling heights. All duct covers are
reversible for recirculating operation.
Ductwork for ZV750/755SPSS
This vent hood must use 6" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation
instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 9' ceiling. ZX7510SPSS can be
ordered to reach 9' to 10' ceiling heights.
Recirculating installation for ZV750/755SPSS
The ZV750/755 hood is designed to be
vented to the outside, but can easily
be converted for recirculating operation.
Recirculating kits are included for
this hood. These kits include charcoal
filters, an air deflector that fits over the
exhaust outlet and a vented decorative
duct cover. Kits are sized for
ceiling height.
Ductwork for ZV800SJSS
This vent hood must use 6" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation
instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 10' ceiling. The duct covers are
reversible for recirculating operation.
Ductwork for ZV900SLSS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover to reach an 8' to 9'5" ceiling. ZX90010 can be ordered to
reach 9'6" to 10'5" ceiling heights. All duct covers are reversible
for recirculating operation.
Ductwork for ZV950SDSS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 10' ceiling. An optional accessory,
ZX14SDSS, can be ordered to reach 10' to 14' ceiling heights.
For vented operation only.
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
45
Advance planning for chimney hoods—wall-mount
*Height
to
Ceiling
29-7/8
5-7/8
13-1/4
10-7/8
18-7/8
*The Supplied Duct Cover Fits 8' to 10' Ceiling Heights.
24" Min.
30" Max.
36" Min.
Product dimensions and clearances
This stainless steel hood can be installed over any 30"
Monogram
®
electric cooktop or gas cooktop.
This vent hood must be installed 24" minimum to 30" maximum
above the cooking surface. The hood installation height above
the cooking surface depends upon ceiling height.
Model ZV830SMSS
The telescopic duct cover
conceals the ductwork
running from the top of
the hood to the ceiling.
Note: The supplied duct
cover is sized to reach
8' to 10' ceiling heights.
For ceiling heights greater
than 10' and up to 12',
order ZX83012 stainless
steel duct cover
accessor y.
Installation height should be measured from the cooking
surface to the lowest part of the hood. This hood may be
installed onto a wall and vented to the outdoors, or it can
be installed for recirculating operation. All necessary parts
for recirculating operation are supplied with the hood.
No kits required.
Charcoal filter replacements are available from your dealer or
by calling 800.626.2002. Order catalog number WB02X11348.
Using duct cover accessories
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
which accessory may be required for your installation.
Wall-mount ZV830 installation heights
Actual Possible vented Possible
ceiling installation recirculating
hei ght heigh t* installation height
7 ' 11" 24" 24"
8' 0" 24" to 25" 24" to 25"
8' 1" 24" to 26" 24" to 26"
8' 2" 24" to 27" 24" to 27"
8' 3" 24" to 28" 24" to 28"
8' 4" 24" to 29" 24" to 29"
8' 5" to 9' 6" 24" to 30" 24" to 30"
9' 7" 25" to 30" 24" to 30"
9' 8" 26" to 30" 24" to 30"
9' 9" 27" to 30" 24" to 30"
9' 10" 28" to 30" 24" to 30"
9' 11" 29" to 30" 29" to 30"
10' 0" 30" 26" to 30"
10' 1" 27" to 30"
10' 2" 28" to 30"
10' 3" 29" to 30"
10' 4" 30"
9' 7" 24"
9' 8" 24" to 25"
9' 9" 24" to 26"
9' 10" 24" to 27"
9' 11" 24" to 28" 24"
10' 0" 24" to 29" 24" to 25"
10' 1" 24" to 30" 24" to 26"
10' 2" 24" to 30" 24" to 27"
10' 3" 24" to 30" 24" to 28"
10' 4" 24" to 30" 24" to 29"
10' 5" 24" to 30" 24" to 30"
10' 6" to 11'6" 24" to 30" 24" to 30"
11' 7" 25" to 30" 24" to 30"
11' 8" 26" to 30" 24" to 30"
11' 9" 27" to 30" 24" to 30"
11' 10" 28" to 30" 24" to 30"
11' 11" 29" to 30" 25" to 30"
12' 0" 30" 26" to 30"
*Based on 36" countertop height .
Supplied
Accessory ZX83012
The serial plate is located behind the removable filters.
46
13-1/4"
ZV830SMSS duct
cover dimensions
28-7/8"
25-1/8"
Note: ZX83012 accessory
consists of one 48-7/8"long duct cover.
10-7/8"