Attractive design. Expertly crafted with uncompromising
attention to detail, a Monogram
architectural highlight to your kitchen.
Powerful ventilation. The variable-speed fan blower provides
the power necessary to capture the smoke and fumes
produced by high-performance cooking equipment.
Halogen lighting. Six levels of intensity are offered for
different needs, from accent to ambient settings.
Removable filters. Filters can be easily detached from
the hood for safe cleaning in your dishwasher.
Recirculating options for ZV750/755.
These hoods may be installed for vented or recirculating
operation. All necessary parts are included. No kits required.
ZV800, ZV830 and ZV900 models are designed to be vented
outdoors or to recirculate into the room air. (Air deflector,
charcoal filter and a reversible duct cover are packed with
models ZV800, ZV830 and ZV900.)
For additional details on product installation, warranty
coverage, care and maintenance, visit monogram.com.
®
hood adds a striking
36" wall-mount glass
canopy hood
ZV900SLSS
Overall dimensions
(WxHxD in inches):
35-7/8 x 3-1/4 x 20-7/16
Amps @ 120VAC 4.3
Approx. shipping wt. (lbs.) 123
•
8" round exhaust duct
•
8'–9'5" ceiling duct
cover included
•
Optional extension duct
covers available
•
Reversible duct cover for
36" wall-mount
vent hood
ZV950SDSS
Overall dimensions
(WxHxD in inches):
35-5/8 x 10 x 25
Amps @ 120VAC 4.5
Approx. shipping wt. (lbs.) 110
•
Dual blowers
•
8" round exhaust duct
•
8'–10' ceiling duct cover
included
•
Optional extension
duct covers available
vented or recirculating
installations.
30" wall-mount
vent hood
36" wall-mount
vent hood
36" wall-mount hood
with retractable
glass canopy
ZV830SMSS
Overall dimensions
(WxHxD in inches):
29-7/8 x 5-7/8 x 18-7/8
Amps @ 120VAC 4.6
Approx. shipping wt. (lbs.) 81
•
8" round exhaust duct
•
8'–10' ceiling duct
cover included
•
Optional extension duct cover
available
•
Reversible duct cover for
vented or recirculating
installations
44
ZV750SPSS
ZV755SPSS
Overall dimensions
(WxHxD in inches):
34-5/8 x 8-1/4 x 21-5/8
Amps @ 120VAC 3.7
Approx. shipping wt. (lbs.) 81
•
6" round exhaust duct
•
8'–9' ceiling duct cover
included
•
Optional extension duct
cover available
•
Reversible duct cover for
vented or recirculating
installations
ZV800SJSS
Overall dimensions
(WxHxD in inches):
36 x 1-1/2 x 18-15/16
(with hood extended)
Amps @ 120VAC 3.3
Approx. shipping wt. (lbs.) 100
•
6" round exhaust duct
•
8'–10' ceiling duct cover
included
•
Reversible duct cover for
vented or recirculating
installations
Advance planning for chimney hoods—wall-mount
monogram.com
Wall-mount hoods
Chimney vent hoods are available in 30" and 36" widths. All
models are supplied with a two-piece stainless steel duct cover
to conceal the ductwork running from the top of the hood to
the ceiling.
• The installation height should be determined in advance.
If necessary, accessories for height adjustment should be
ordered with the vent hood and be on-site at the time of
installation.
• Review the following chart to determine the need for an
accessory duct cover.
Duct cover accessories for vented installations
Ceiling
height
8'Included IncludedIncluded Includedup to 9'5"
Up to 9'Included IncludedIncludedIncluded up to 9'5"
Up to 10' Included ZX7510SPSS IncludedIncluded ZX90010*
10' to 12' ZX83012————
10' to 14'——ZX14SDSS——
*ZX90010 for 9'6" up to 10'5"
ZV830ZV750/
755
ZV950ZV800ZV900
Structural support
These vent hoods are heavy. Adequate structural support
must be provided. Hoods must be secured to vertical studs
in the wall or to horizontal supports.
• It is strongly recommended that the vent hood and duct
cover(s) if used, be on-site before final framing and wall
finishing. This will help to accurately locate the ductwork
and electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop below.
• Mounting templates are provided with the installation
instructions to help accurately position the hood above the
cooking surface.
Electrical requirements
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15- or 20-amp circuit breaker or time-delay fuse.
Ductwork planning
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
Ductwork for ZV830SMSS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 10' ceiling. ZX83012 can be
ordered to reach 10' to 12' ceiling heights. All duct covers are
reversible for recirculating operation.
Ductwork for ZV750/755SPSS
This vent hood must use 6" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation
instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 9' ceiling. ZX7510SPSS can be
ordered to reach 9' to 10' ceiling heights.
Recirculating installation for ZV750/755SPSS
The ZV750/755 hood is designed to be
vented to the outside, but can easily
be converted for recirculating operation.
Recirculating kits are included for
this hood. These kits include charcoal
filters, an air deflector that fits over the
exhaust outlet and a vented decorative
duct cover. Kits are sized for
ceiling height.
Ductwork for ZV800SJSS
This vent hood must use 6" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Refer to the duct fittings chart in the installation
instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 10' ceiling. The duct covers are
reversible for recirculating operation.
Ductwork for ZV900SLSS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover to reach an 8' to 9'5" ceiling. ZX90010 can be ordered to
reach 9'6" to 10'5" ceiling heights. All duct covers are reversible
for recirculating operation.
Ductwork for ZV950SDSS
This vent hood must use 8" round duct with a maximum
equivalent length of 100 feet for any duct configuration.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct
cover that will reach an 8' to 10' ceiling. An optional accessory,
ZX14SDSS, can be ordered to reach 10' to 14' ceiling heights.
For vented operation only.
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
45
Advance planning for chimney hoods—wall-mount
*Height
to
Ceiling
29-7/8
5-7/8
13-1/4
10-7/8
18-7/8
*The Supplied Duct Cover Fits 8' to 10' Ceiling Heights.
24" Min.
30" Max.
36" Min.
Product dimensions and clearances
This stainless steel hood can be installed over any 30"
Monogram
®
electric cooktop or gas cooktop.
This vent hood must be installed 24" minimum to 30" maximum
above the cooking surface. The hood installation height above
the cooking surface depends upon ceiling height.
Model ZV830SMSS
The telescopic duct cover
conceals the ductwork
running from the top of
the hood to the ceiling.
Note: The supplied duct
cover is sized to reach
8' to 10' ceiling heights.
For ceiling heights greater
than 10' and up to 12',
order ZX83012 stainless
steel duct cover
accessor y.
Installation height should be measured from the cooking
surface to the lowest part of the hood. This hood may be
installed onto a wall and vented to the outdoors, or it can
be installed for recirculating operation. All necessary parts
for recirculating operation are supplied with the hood.
No kits required.
Charcoal filter replacements are available from your dealer or
by calling 800.626.2002. Order catalog number WB02X11348.
Using duct cover accessories
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
which accessory may be required for your installation.
Wall-mount ZV830 installation heights
Actual Possible vented Possible
ceiling installation recirculating
hei ght heigh t* installation height
7 ' 11" 24" 24"
8' 0" 24" to 25" 24" to 25"
8' 1" 24" to 26" 24" to 26"
8' 2" 24" to 27" 24" to 27"
8' 3" 24" to 28" 24" to 28"
8' 4" 24" to 29" 24" to 29"
8' 5" to 9' 6" 24" to 30" 24" to 30"
9' 7" 25" to 30" 24" to 30"
9' 8" 26" to 30" 24" to 30"
9' 9" 27" to 30" 24" to 30"
9' 10" 28" to 30" 24" to 30"
9' 11" 29" to 30" 29" to 30"
10' 0" 30" 26" to 30"
10' 1" 27" to 30"
10' 2" 28" to 30"
10' 3" 29" to 30"
10' 4" 30"
9' 7" 24"
9' 8" 24" to 25"
9' 9" 24" to 26"
9' 10" 24" to 27"
9' 11" 24" to 28" 24"
10' 0" 24" to 29" 24" to 25"
10' 1" 24" to 30" 24" to 26"
10' 2" 24" to 30" 24" to 27"
10' 3" 24" to 30" 24" to 28"
10' 4" 24" to 30" 24" to 29"
10' 5" 24" to 30" 24" to 30"
10' 6" to 11'6" 24" to 30" 24" to 30"
11' 7" 25" to 30" 24" to 30"
11' 8" 26" to 30" 24" to 30"
11' 9" 27" to 30" 24" to 30"
11' 10" 28" to 30" 24" to 30"
11' 11" 29" to 30" 25" to 30"
12' 0" 30" 26" to 30"
*Based on 36" countertop height .
Supplied
Accessory ZX83012
The serial plate is located behind the removable filters.
46
13-1/4"
ZV830SMSS duct
cover dimensions
28-7/8"
25-1/8"
Note: ZX83012 accessory
consists of one 48-7/8"long duct cover.
This stainless steel hood can be installed over any Monogram
cooktop except Professional models.
Model ZV750/755SPSS
* 26-1/4" for 8' ceiling
38-1/4" for 9' ceiling
With accessory
ZX750SPSS duct cover:
38-1/4" to 50-1/4" for
9' to 10' ceiling.
This vent hood must be installed 24" minimum to 30" maximum
above the cooking surface; 25-1/2" is recommended to insure
that the duct cover meets the ceiling. The cooking surface
should be at least 36" above the floor. Installation height must
be determined in advance. If needed, the ZX7510SPSS duct
cover accessory should be ordered with the vent hood and
be on-site at the time of installation. A mounting template is
provided with the installation instructions to help position the
hood above the cooking surface and to locate the mounting
brackets.
Charcoal filter replacements are available from your dealer or
by calling 800.626.2002. Order catalog number WB02X10731.
Using duct cover accessories
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
which accessory may be required for your installation
ZV750/ZV755 installation heights
Upper (Inner) Duc t Cover (B)
Lower (Outer) Duct Cover (A)
Accessory Lower (Outer) Duct Cover (A)
Ac tual
ceiling
height
7' 11"24" to 28"24" to 28"
8' 0"24" to 29"24" to 29"
8' 1"24" to 30"24" to 30"
8' 2"24" to 30"24" to 30"
8' 3"24" to 30"24" to 30"
8' 4"24" to 30"24" to 30"
8' 5"24" to 30"24" to 30"
8' 6"24" to 30"24" to 30"
8' 7"24" to 30"24" to 30"
8' 8"24" to 30"24" to 30"
8' 9"25" to 30"24" to 30"
8' 10"26" to 30"24" to 30"
8' 11"27" to 30"24" to 30"
9' 0"28" to 30"24" to 30"
9' 1"29" to 30"25" to 30"
9' 2"30"26" to 30"
9' 3"27" to 30"
9' 4"28" to 30"
9' 5"29" to 30"
9' 6"30"
9' 0"24" to 30"24" to 28"
9' 1"24" to 30"24" to 29"
9' 2"24" to 30"24" to 30"
9' 3"24" to 30"24" to 30"
9' 4"24" to 30"24" to 30"
9' 5"24" to 30"24" to 30"
9' 6"24" to 30"24" to 30"
9' 7"24" to 30"24" to 30"
9' 8"24" to 30"24" to 30"
9' 9"24" to 30"24" to 30"
9' 10"25" to 30"24" to 30"
9' 11"26" to 30"24" to 30"
10' 0"27" to 30"24" to 30"
10' 1"28" to 30"24" to 30"
10' 2"29" to 30"24" to 30"
10' 3"30"25" to 30"
10' 4"26" to 30"
10' 5"27" to 30"
10' 6"28" to 30"
10' 7"29" to 30"
10' 8"30"
*Based on 36" countertop height .
Vented
installation
height*
Recirculating
installation
height
.
Supplied
ZX7510SP SS (need accessory lower duct cover 31-1/2")
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
Duct Cover Dimensions
ZX7510SPSS Duct Cover
Accessory
This accessory is available for
installation with ceiling heights
above 9' to 10' and higher. This
accessory consists of one 31-1/2"
lower duct cover.
18-1/2"
24-1/4"
Supplied
duct cover
47
Advance planning for chimney hoods—wall-mount
10"
*Height
to Ceiling
35-5/8"
25"
Installation
Height Depending
on Ceiling Height
36" Min.
Product dimensions and clearances
This stainless steel hood can be installed over any Monogram®
cooktop including a Professional 36" rangetop and a 36" or 30"
Professional range.
This vent hood must be installed 24" minimum to 30" maximum
above the cooking surface. The hood installation height, from
the cooktop surface to the bottom of the hood, depends upon
ceiling height.
Model ZV950SDSS
* 24-1/2" for 8' ceiling
36-1/2" for 9' ceiling
36" to 44" for 9' to 10'
ceiling. (For ceilings between
9'6" and 10', mount the
hood 30" above the
cooking surface.)
Note: The supplied two-piece duct cover is adjustable to
fit 8' to 10' ceilings. For ceiling heights greater than 10'
and up to 14', order ZX14SDSS stainless steel duct cover
accessor y.
The distance between the cooking surface and the bottom
of the hood should be:
25-1/2" maximum for 8' ceiling height.
25-1/2" to 30" for 9' ceiling height.
30" minimum for 10' ceiling height.
Using duct cover accessories
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
installation height and the need for a duct cover accessory.
ZV950SDSS installation heights
Ac tual
ceiling height
7' 11"24-1/2"
8' 0"25-1/2"
8' 1"25-1/2" to 26-1/2"
8' 2"25-1/2" to 27-1/2"
8' 3"25-1/2" to 28-1/2"
8' 4"25-1/2" to 29-1/2"
8' 5"25-1/2" to 30"
8' 6"25-1/2" to 30"
8' 7"25-1/2" to 30"
8' 8"25-1/2" to 30"
8' 9"25-1/2" to 30"
8' 10"25-1/2" to 30"
8' 11"25-1/2" to 30"
9' 0"25-1/2" to 30"
9' 1"26-1/2" to 30"
9' 2"26-1/2" to 30"
9' 3"26-1/2" to 30"
9' 4"26-1/2" to 30"
9' 5"26-1/2" to 30"
9' 6"30" minimum
9' 7"30" minimum
9' 8"30" minimum
9' 9"30" minimum
9' 10"30" minimum
9' 11"30" minimum
10' 0"—14" 0"30" minimumZX14SDS S
*Based on 36" countertop height .
Possible hood
installation
height*
Duct
cover
accessory
Supplied
Plan the installation height carefully to avoid unsightly gaps
ZV950DSS duct
cover dimensions
The serial plate is located behind the removable filters.
ZX14DSS duct
cover dimensions
above the hood. A mounting template is provided with the
installation instructions to help position the hood above the
cooking surface and to locate the mounting brackets.
Note: Install the hood 30" minimum above the cooking
surface over a Professional range or rangetop.
Installation over a professional range
or rangetop
The ZV950 hood must be installed 30" minimum above the
cooking surface of a Professional range or rangetop.
The ceiling height must be at least 8'5" for this installation
48
combination.
Advance planning for chimney hoods—wall-mount
monogram.com
Product dimensions and clearances
This vent hood can be installed for vented or recirculating
operation. It can be installed over any 30" or 36" Monogram
cooktop (except Professional models).
ZV800SJSS, Stainless steel
Telescoping duct covers
are provided to reach
8' to 10' ceiling heights.
The canopy extends
forward 5-7/8".
Venting and recirculating
wall-mount installations
The vent hood must be
installed 24" minimum to
30" maximum above the
standard 36" countertop.
The hood installation height,
from the cooking surface to
the bottom of the hood,
depends on the ceiling height.
Vented or recirculating
installations in a cabinet
The vent hood height must
be at least 24" minimum above
the standard 36" countertop.
• In both vented and
recirculating installations,
the cabinet must measure
at least 20" from the bottom
frame to the inside top.
• The cabinet must be at
least 12" deep. The hood
housing will occupy the
interior cabinet space.
Louver at top of cabinet
in this example
A mounting template is provided with the installation
instructions to help position the hood above the cooking
surface and to locate the mounting brackets.
Determine installation height
Use this chart to accurately determine installation height,
depending on your ceiling height.
Wall-mount ZV800 installation heights
Actual ceiling Possible vented Possible recirculating
height installation height* installation
7' 11" 24" to 27" 24" to 25"
8' 0" 24" to 28" 24" to 26"
8' 1" 24" to 30" 24" to 27"
8' 2" 24" to 30" 24" to 28"
8' 3" 24" to 30" 24" to 29"
8' 4" 24" to 30" 24" to 30"
8' 5" 24" to 30" 24" to 30"
8' 6" 24" to 30" 24" to 30"
8' 7" 24" to 30" 24" to 30"
8' 8" 24" to 30" 24" to 30"
8' 9" 24" to 30" 24" to 30"
8' 10" 24" to 30" 24" to 30"
8' 11" 24" to 30" 24" to 30"
9' 0" 24" to 30" 24" to 30"
9' 1" 24" to 30" 24" to 30"
9' 2" 24" to 30" 24" to 30"
9' 3" 24" to 30" 24" to 30"
9' 4" 24" to 30" 24" to 30"
9' 5" 24" to 30" 24" to 30"
9' 6" 24" to 30" 24" to 30"
9' 7" 25" to 30" 24" to 30"
9' 8" 26" to 30" 24" to 30"
9' 9" 27" to 30" 24" to 30"
9' 10" 28" to 30" 24" to 30"
9' 11" 29" to 30" 25" to 30"
10' 0" 30" 26" to 30"
*Based on 36" countertop height .
ZV800SJSS duct cover dimensions
The serial plate is located behind the removable filters.
Charcoal filter replacements are available from your dealer or
by calling 800.626.2002. Order catalog number WB02X11343.
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
Recirculating installation
• The exhaust must be returned to the kitchen; it cannot exit
inside the cabinet.
• The exhaust can be directed through the soffit or upper
cabinet to a vent opening with a minimum of 28 square
inches or 6" round. A customer-supplied decorative louver
should be installed.
• The exhaust, either exposed or hidden, should be directed
away from other cabinet surfaces.
49
Advance planning for chimney hoods—wall-mount
*Height
to
Ceiling
20-7/16"
3-1/4"
35-7/8"
Product dimensions and clearances
This glass canopy hood can be installed over any 30" or 36"
Monogram
®
cooktop (except Professional models).
Model ZV900SLSS
* The supplied duct
cover is sized to
fit 8' to 9'5" ceiling
heights. For 9'6"
to 10'5" ceilings,
order ZX90010.
NOTE: Measure
installation height
from the cooking
surface to the
outer glass portion
of the hood.
24" Min.
30" Max.
36" Min.
• The vent hood must be installed 24" minimum to 30"
maximum above the cooking surface. The hood installation
height above the cooking surface depends upon the ceiling
height.
• The cooking surface should be at least 36" above the floor.
• This hood can be installed for recirculating operation.
No kits required.
A mounting template is provided with the installation
instructions to help position the hood above the cooking
surface and to locate the mounting brackets.
Determine installation height
Use this chart to accurately determine installation height,
depending on your ceiling height.
Wall-mount ZV900 installation heights
Ac tual
ceiling
height
7' 11"24" to 26"24" to 25"
8' 0"24" to 27"24" to 26"
8' 1"24" to 28"24" to 27"
8' 2"24" to 29"24" to 28"
8' 3"24" to 30"24" to 29"
8' 4"24" to 30"24" to 30"
8' 5"24" to 30"24" to 30"
8' 6"24" to 30"24" to 30"
8' 7"24" to 30"24" to 30"
8' 8"24" to 30"24" to 30"
8' 9"24" to 30"24" to 30"
8' 10"24" to 30"24" to 30"
8' 11"24" to 30"24" to 30"
9' 0"24" to 30"24" to 30"
9' 1"26" to 30"24" to 30"
9' 2"27" to 30"24" to 30"
9' 3"28" to 30"24" to 30"
9' 4"29" to 30"24" to 30"
9' 5"30"24" to 30"
9' 6"24" to 30"24" to 30"
9' 7"24" to 30"24" to 30"
9' 8"24" to 30"24" to 30"
9' 9"24" to 30"24" to 30"
9' 10"24" to 30"24" to 30"
9' 11"24" to 30"24" to 30"
10' 0"24" to 30"24" to 30"
10' 1"24" to 30"24" to 30"
10' 2"25" to 30"24" to 30"
10' 3"26" to 30"25" to 30"
10' 4"27" to 30"26" to 30"
10' 5"28" to 30"27" to 30"
*Based on 36" countertop height .
Possible vented
installation
height*
Possible
recirculating
installation*
Duct cover
accessory
Supplied
Accessory ZX90010
Charcoal filter replacements are available from your dealer or
by calling 800.626.2002. Order catalog number WB02X11284.
ZV900SLSS duct cover dimensions
NOTE: ZX90010 accessory consists of one 40"-long duct cover.
The serial plate is located behind the removable filters.
50
Pairing hoods with cooking equipment
Monogram® hoods are designed to perfectly coordinate with Monogram ranges and cooktops. To learn which cooking products can
be combined with the hood you have selected, refer to the charts below.
7'11" to 8'5" duct
cover included,
8'6" to 10'4" duct
cover optional
All Monogram
cooktops and
ranges
13.0
430/2.5
7'11" to 8'5" duct
cover included,
8'6" to 10'4" duct
cover optionalN/AN/A
ZVC36LSS
ZVC30LSS
All 30" and 36"
cooktops and
ranges
14.0
250/3.5
ZVC48LSS
ZVC42LSS
All Monogram
cooktops and
ranges
16.5
490/4.0
The Home Ventilating Institute (HVI) is a third-party certification
organization focused on providing a fair and credible method
of comparing ventilation performance of similar products.
Many agencies such as ENERGY STAR
®
and ASHRAE utilize
HVI certification for performance assurance. All Monogram
ventilation products are certified by HVI.
Some key performance criteria measured by HVI are sound
level measured in sones, high speed and working speed
measured in cubic feet per minute (cfm).
A sone is an internationally recognized measurement of sound
output. Sones translate decibel ratings into numbers that
correspond to the way people sense loudness. The lower the
sone number the quieter the sound.
Working speed is defined as the speed that produces
100 cfm, or the lowest speed above 100 cfm that a hood
can produce, when working on the same duct system as the
maximum speed.
(HVI916, March 1, 2009) (http://hvi.org/faqs.html)
monogram.com
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
43
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.