GE ZV755SPSS User Manual

Chimney hoods—wall-mount
Monogram
FAN
LIGHT
-+-
+
General features
Attractive design. Expertly crafted with uncompromising
attention to detail, a Monogram architectural highlight to your kitchen.
Powerful ventilation. The variable-speed fan blower provides the power necessary to capture the smoke and fumes produced by high-performance cooking equipment.
Halogen lighting. Six levels of intensity are offered for different needs, from accent to ambient settings.
Removable filters. Filters can be easily detached from the hood for safe cleaning in your dishwasher.
Recirculating options for ZV750/755. These hoods may be installed for vented or recirculating operation. All necessary parts are included. No kits required. ZV800, ZV830 and ZV900 models are designed to be vented outdoors or to recirculate into the room air. (Air deflector, charcoal filter and a reversible duct cover are packed with models ZV800, ZV830 and ZV900.)
For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com.
®
hood adds a striking
36" wall-mount glass canopy hood
ZV900SLSS
Overall dimensions (WxHxD in inches): 35-7/8 x 3-1/4 x 20-7/16
8" round exhaust duct
8'–9'5" ceiling duct
cover included
Optional extension duct
covers available
Reversible duct cover for
36" wall-mount vent hood
ZV950SDSS
Overall dimensions (WxHxD in inches): 35-5/8 x 10 x 25
Dual blowers
8" round exhaust duct
8'–10' ceiling duct cover
included
Optional extension
duct covers available
vented or recirculating installations.
30" wall-mount vent hood
36" wall-mount vent hood
36" wall-mount hood with retractable glass canopy
ZV830SMSS
Overall dimensions (WxHxD in inches): 29-7/8 x 5-7/8 x 18-7/8
Amps @ 120VAC 4.6 Approx. shipping wt. (lbs.) 81
8" round exhaust duct
8'–10' ceiling duct
cover included
Optional extension duct cover
available
Reversible duct cover for
vented or recirculating installations
44
ZV750SPSS ZV755SPSS
Overall dimensions (WxHxD in inches): 34-5/8 x 8-1/4 x 21-5/8
6" round exhaust duct
8'–9' ceiling duct cover
included
Optional extension duct
cover available
Reversible duct cover for
vented or recirculating installations
ZV800SJSS
Overall dimensions (WxHxD in inches): 36 x 1-1/2 x 18-15/16 (with hood extended)
6" round exhaust duct
8'–10' ceiling duct cover
included
Reversible duct cover for
vented or recirculating installations
Advance planning for chimney hoods—wall-mount
monogram.com
Wall-mount hoods
Chimney vent hoods are available in 30" and 36" widths. All models are supplied with a two-piece stainless steel duct cover to conceal the ductwork running from the top of the hood to the ceiling.
• The installation height should be determined in advance.
If necessary, accessories for height adjustment should be ordered with the vent hood and be on-site at the time of installation.
• Review the following chart to determine the need for an
accessory duct cover.
Duct cover accessories for vented installations
Ceiling height
8' Included Included Included Included up to 9'5" Up to 9' Included Included Included Included up to 9'5" Up to 10' Included ZX7510SPSS Included Included ZX90010* 10' to 12' ZX83012 — 10' to 14' ZX14SDSS — *ZX90010 for 9'6" up to 10'5"
ZV830 ZV750/
755
ZV950 ZV800 ZV900
Structural support
These vent hoods are heavy. Adequate structural support must be provided. Hoods must be secured to vertical studs in the wall or to horizontal supports.
• It is strongly recommended that the vent hood and duct
cover(s) if used, be on-site before final framing and wall finishing. This will help to accurately locate the ductwork and electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop below.
• Mounting templates are provided with the installation
instructions to help accurately position the hood above the cooking surface.
Electrical requirements
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15- or 20-amp circuit breaker or time-delay fuse.
Ductwork planning
• Plan the shortest and straightest route for venting exhaust
to the outdoors.
• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition needed in advance.
Ductwork for ZV830SMSS
This vent hood must use 8" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct cover that will reach an 8' to 10' ceiling. ZX83012 can be ordered to reach 10' to 12' ceiling heights. All duct covers are reversible for recirculating operation.
Ductwork for ZV750/755SPSS
This vent hood must use 6" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct cover that will reach an 8' to 9' ceiling. ZX7510SPSS can be ordered to reach 9' to 10' ceiling heights.
Recirculating installation for ZV750/755SPSS
The ZV750/755 hood is designed to be vented to the outside, but can easily be converted for recirculating operation. Recirculating kits are included for this hood. These kits include charcoal filters, an air deflector that fits over the exhaust outlet and a vented decorative duct cover. Kits are sized for ceiling height.
Ductwork for ZV800SJSS
This vent hood must use 6" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct cover that will reach an 8' to 10' ceiling. The duct covers are reversible for recirculating operation.
Ductwork for ZV900SLSS
This vent hood must use 8" round duct with a maximum equivalent length of 100 feet for any duct configuration. Refer to the duct fittings chart in the installation instructions.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct cover to reach an 8' to 9'5" ceiling. ZX90010 can be ordered to reach 9'6" to 10'5" ceiling heights. All duct covers are reversible for recirculating operation.
Ductwork for ZV950SDSS
This vent hood must use 8" round duct with a maximum equivalent length of 100 feet for any duct configuration.
Decorative duct covers
This vent hood is supplied with a two-piece decorative duct cover that will reach an 8' to 10' ceiling. An optional accessory, ZX14SDSS, can be ordered to reach 10' to 14' ceiling heights. For vented operation only.
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
45
Advance planning for chimney hoods—wall-mount
*Height
to
Ceiling
29-7/8
5-7/8
13-1/4
10-7/8
18-7/8
*The Supplied Duct Cover Fits 8' to 10' Ceiling Heights.
24" Min.
30" Max.
36" Min.
Product dimensions and clearances
This stainless steel hood can be installed over any 30" Monogram
®
electric cooktop or gas cooktop.
This vent hood must be installed 24" minimum to 30" maximum above the cooking surface. The hood installation height above the cooking surface depends upon ceiling height.
Model ZV830SMSS
The telescopic duct cover conceals the ductwork running from the top of the hood to the ceiling.
Note: The supplied duct cover is sized to reach 8' to 10' ceiling heights. For ceiling heights greater than 10' and up to 12', order ZX83012 stainless steel duct cover accessor y.
Installation height should be measured from the cooking surface to the lowest part of the hood. This hood may be installed onto a wall and vented to the outdoors, or it can be installed for recirculating operation. All necessary parts for recirculating operation are supplied with the hood. No kits required.
Charcoal filter replacements are available from your dealer or by calling 800.626.2002. Order catalog number WB02X11348.
Using duct cover accessories
A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine which accessory may be required for your installation.
Wall-mount ZV830 installation heights
Actual Possible vented Possible ceiling installation recirculating hei ght heigh t* installation height
7 ' 11" 24" 24" 8' 0" 24" to 25" 24" to 25" 8' 1" 24" to 26" 24" to 26" 8' 2" 24" to 27" 24" to 27" 8' 3" 24" to 28" 24" to 28" 8' 4" 24" to 29" 24" to 29" 8' 5" to 9' 6" 24" to 30" 24" to 30" 9' 7" 25" to 30" 24" to 30" 9' 8" 26" to 30" 24" to 30" 9' 9" 27" to 30" 24" to 30" 9' 10" 28" to 30" 24" to 30" 9' 11" 29" to 30" 29" to 30" 10' 0" 30" 26" to 30" 10' 1" 27" to 30" 10' 2" 28" to 30" 10' 3" 29" to 30" 10' 4" 30" 9' 7" 24" 9' 8" 24" to 25" 9' 9" 24" to 26" 9' 10" 24" to 27" 9' 11" 24" to 28" 24" 10' 0" 24" to 29" 24" to 25" 10' 1" 24" to 30" 24" to 26" 10' 2" 24" to 30" 24" to 27" 10' 3" 24" to 30" 24" to 28" 10' 4" 24" to 30" 24" to 29" 10' 5" 24" to 30" 24" to 30" 10' 6" to 11'6" 24" to 30" 24" to 30" 11' 7" 25" to 30" 24" to 30" 11' 8" 26" to 30" 24" to 30" 11' 9" 27" to 30" 24" to 30" 11' 10" 28" to 30" 24" to 30" 11' 11" 29" to 30" 25" to 30" 12' 0" 30" 26" to 30"
*Based on 36" countertop height .
Supplied
Accessory ZX83012
The serial plate is located behind the removable filters.
46
13-1/4"
ZV830SMSS duct cover dimensions
28-7/8"
25-1/8"
Note: ZX83012 accessory consists of one 48-7/8"­long duct cover.
10-7/8"
Advance planning for chimney hoods—wall-mount
*Height
to Ceiling
8-1/4"
34-5/8" (excluding utensil rod) 35-3/4" (including utensil rod)
21-5/8"
24" to 30"
36" Min.
monogram.com
Product dimensions and clearances
This stainless steel hood can be installed over any Monogram cooktop except Professional models.
Model ZV750/755SPSS
* 26-1/4" for 8' ceiling
38-1/4" for 9' ceiling
With accessory ZX750SPSS duct cover: 38-1/4" to 50-1/4" for 9' to 10' ceiling.
This vent hood must be installed 24" minimum to 30" maximum above the cooking surface; 25-1/2" is recommended to insure that the duct cover meets the ceiling. The cooking surface should be at least 36" above the floor. Installation height must be determined in advance. If needed, the ZX7510SPSS duct cover accessory should be ordered with the vent hood and be on-site at the time of installation. A mounting template is provided with the installation instructions to help position the hood above the cooking surface and to locate the mounting brackets.
Charcoal filter replacements are available from your dealer or by calling 800.626.2002. Order catalog number WB02X10731.
Using duct cover accessories
A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine which accessory may be required for your installation
ZV750/ZV755 installation heights
Upper (Inner) Duc t Cover (B)
Lower (Outer) Duct Cover (A)
Accessory Lower (Outer) Duct Cover (A)
Ac tual ceiling height
7' 11" 24" to 28" 24" to 28" 8' 0" 24" to 29" 24" to 29" 8' 1" 24" to 30" 24" to 30" 8' 2" 24" to 30" 24" to 30" 8' 3" 24" to 30" 24" to 30" 8' 4" 24" to 30" 24" to 30" 8' 5" 24" to 30" 24" to 30" 8' 6" 24" to 30" 24" to 30" 8' 7" 24" to 30" 24" to 30" 8' 8" 24" to 30" 24" to 30" 8' 9" 25" to 30" 24" to 30" 8' 10" 26" to 30" 24" to 30" 8' 11" 27" to 30" 24" to 30" 9' 0" 28" to 30" 24" to 30" 9' 1" 29" to 30" 25" to 30" 9' 2" 30" 26" to 30" 9' 3" 27" to 30" 9' 4" 28" to 30" 9' 5" 29" to 30" 9' 6" 30" 9' 0" 24" to 30" 24" to 28" 9' 1" 24" to 30" 24" to 29" 9' 2" 24" to 30" 24" to 30" 9' 3" 24" to 30" 24" to 30" 9' 4" 24" to 30" 24" to 30" 9' 5" 24" to 30" 24" to 30" 9' 6" 24" to 30" 24" to 30" 9' 7" 24" to 30" 24" to 30" 9' 8" 24" to 30" 24" to 30" 9' 9" 24" to 30" 24" to 30" 9' 10" 25" to 30" 24" to 30" 9' 11" 26" to 30" 24" to 30" 10' 0" 27" to 30" 24" to 30" 10' 1" 28" to 30" 24" to 30" 10' 2" 29" to 30" 24" to 30" 10' 3" 30" 25" to 30" 10' 4" 26" to 30" 10' 5" 27" to 30" 10' 6" 28" to 30" 10' 7" 29" to 30" 10' 8" 30"
*Based on 36" countertop height .
Vented installation height*
Recirculating installation height
.
Supplied
ZX7510SP SS (need accessory lower duct cover 31-1/2")
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
Duct Cover Dimensions ZX7510SPSS Duct Cover
Accessory
This accessory is available for installation with ceiling heights above 9' to 10' and higher. This accessory consists of one 31-1/2" lower duct cover.
18-1/2"
24-1/4"
Supplied duct cover
47
Advance planning for chimney hoods—wall-mount
10"
*Height to Ceiling
35-5/8"
25"
Installation
Height Depending
on Ceiling Height
36" Min.
Product dimensions and clearances
This stainless steel hood can be installed over any Monogram® cooktop including a Professional 36" rangetop and a 36" or 30" Professional range.
This vent hood must be installed 24" minimum to 30" maximum above the cooking surface. The hood installation height, from the cooktop surface to the bottom of the hood, depends upon ceiling height.
Model ZV950SDSS
* 24-1/2" for 8' ceiling
36-1/2" for 9' ceiling 36" to 44" for 9' to 10' ceiling. (For ceilings between 9'6" and 10', mount the hood 30" above the cooking surface.)
Note: The supplied two-piece duct cover is adjustable to fit 8' to 10' ceilings. For ceiling heights greater than 10' and up to 14', order ZX14SDSS stainless steel duct cover accessor y.
The distance between the cooking surface and the bottom of the hood should be:
25-1/2" maximum for 8' ceiling height. 25-1/2" to 30" for 9' ceiling height. 30" minimum for 10' ceiling height.
Using duct cover accessories
A duct cover accessory may be required for your hood installation height. Use this chart to accurately determine installation height and the need for a duct cover accessory.
ZV950SDSS installation heights
Ac tual ceiling height
7' 11" 24-1/2" 8' 0" 25-1/2" 8' 1" 25-1/2" to 26-1/2" 8' 2" 25-1/2" to 27-1/2" 8' 3" 25-1/2" to 28-1/2" 8' 4" 25-1/2" to 29-1/2" 8' 5" 25-1/2" to 30" 8' 6" 25-1/2" to 30" 8' 7" 25-1/2" to 30" 8' 8" 25-1/2" to 30" 8' 9" 25-1/2" to 30" 8' 10" 25-1/2" to 30" 8' 11" 25-1/2" to 30" 9' 0" 25-1/2" to 30" 9' 1" 26-1/2" to 30" 9' 2" 26-1/2" to 30" 9' 3" 26-1/2" to 30" 9' 4" 26-1/2" to 30" 9' 5" 26-1/2" to 30" 9' 6" 30" minimum 9' 7" 30" minimum 9' 8" 30" minimum 9' 9" 30" minimum 9' 10" 30" minimum 9' 11" 30" minimum 10' 0"—14" 0" 30" minimum ZX14SDS S
*Based on 36" countertop height .
Possible hood installation height*
Duct cover accessory
Supplied
Plan the installation height carefully to avoid unsightly gaps
ZV950DSS duct cover dimensions
The serial plate is located behind the removable filters.
ZX14DSS duct cover dimensions
above the hood. A mounting template is provided with the installation instructions to help position the hood above the cooking surface and to locate the mounting brackets.
Note: Install the hood 30" minimum above the cooking surface over a Professional range or rangetop.
Installation over a professional range or rangetop
The ZV950 hood must be installed 30" minimum above the cooking surface of a Professional range or rangetop. The ceiling height must be at least 8'5" for this installation
48
combination.
Advance planning for chimney hoods—wall-mount
monogram.com
Product dimensions and clearances
This vent hood can be installed for vented or recirculating operation. It can be installed over any 30" or 36" Monogram cooktop (except Professional models).
ZV800SJSS, Stainless steel
Telescoping duct covers are provided to reach 8' to 10' ceiling heights.
The canopy extends forward 5-7/8".
Venting and recirculating wall-mount installations
The vent hood must be installed 24" minimum to 30" maximum above the standard 36" countertop. The hood installation height, from the cooking surface to the bottom of the hood, depends on the ceiling height.
Vented or recirculating installations in a cabinet
The vent hood height must be at least 24" minimum above the standard 36" countertop.
• In both vented and recirculating installations, the cabinet must measure at least 20" from the bottom frame to the inside top.
• The cabinet must be at least 12" deep. The hood housing will occupy the interior cabinet space.
Louver at top of cabinet in this example
A mounting template is provided with the installation instructions to help position the hood above the cooking surface and to locate the mounting brackets.
Determine installation height
Use this chart to accurately determine installation height, depending on your ceiling height.
Wall-mount ZV800 installation heights
Actual ceiling Possible vented Possible recirculating height installation height* installation
7' 11" 24" to 27" 24" to 25" 8' 0" 24" to 28" 24" to 26" 8' 1" 24" to 30" 24" to 27" 8' 2" 24" to 30" 24" to 28" 8' 3" 24" to 30" 24" to 29" 8' 4" 24" to 30" 24" to 30" 8' 5" 24" to 30" 24" to 30" 8' 6" 24" to 30" 24" to 30" 8' 7" 24" to 30" 24" to 30" 8' 8" 24" to 30" 24" to 30" 8' 9" 24" to 30" 24" to 30" 8' 10" 24" to 30" 24" to 30" 8' 11" 24" to 30" 24" to 30" 9' 0" 24" to 30" 24" to 30" 9' 1" 24" to 30" 24" to 30" 9' 2" 24" to 30" 24" to 30" 9' 3" 24" to 30" 24" to 30" 9' 4" 24" to 30" 24" to 30" 9' 5" 24" to 30" 24" to 30" 9' 6" 24" to 30" 24" to 30" 9' 7" 25" to 30" 24" to 30" 9' 8" 26" to 30" 24" to 30" 9' 9" 27" to 30" 24" to 30" 9' 10" 28" to 30" 24" to 30" 9' 11" 29" to 30" 25" to 30" 10' 0" 30" 26" to 30"
*Based on 36" countertop height .
ZV800SJSS duct cover dimensions
The serial plate is located behind the removable filters.
Charcoal filter replacements are available from your dealer or by calling 800.626.2002. Order catalog number WB02X11343.
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
Recirculating installation
• The exhaust must be returned to the kitchen; it cannot exit
inside the cabinet.
• The exhaust can be directed through the soffit or upper
cabinet to a vent opening with a minimum of 28 square inches or 6" round. A customer-supplied decorative louver should be installed.
• The exhaust, either exposed or hidden, should be directed
away from other cabinet surfaces.
49
Advance planning for chimney hoods—wall-mount
*Height
to
Ceiling
20-7/16"
3-1/4"
35-7/8"
Product dimensions and clearances
This glass canopy hood can be installed over any 30" or 36" Monogram
®
cooktop (except Professional models).
Model ZV900SLSS
* The supplied duct
cover is sized to fit 8' to 9'5" ceiling heights. For 9'6" to 10'5" ceilings, order ZX90010.
NOTE: Measure installation height from the cooking surface to the outer glass portion of the hood.
24" Min.
30" Max.
36" Min.
• The vent hood must be installed 24" minimum to 30" maximum above the cooking surface. The hood installation height above the cooking surface depends upon the ceiling height.
• The cooking surface should be at least 36" above the floor.
• This hood can be installed for recirculating operation.
No kits required.
A mounting template is provided with the installation instructions to help position the hood above the cooking surface and to locate the mounting brackets.
Determine installation height
Use this chart to accurately determine installation height, depending on your ceiling height.
Wall-mount ZV900 installation heights Ac tual
ceiling height
7' 11" 24" to 26" 24" to 25" 8' 0" 24" to 27" 24" to 26" 8' 1" 24" to 28" 24" to 27" 8' 2" 24" to 29" 24" to 28" 8' 3" 24" to 30" 24" to 29" 8' 4" 24" to 30" 24" to 30" 8' 5" 24" to 30" 24" to 30" 8' 6" 24" to 30" 24" to 30" 8' 7" 24" to 30" 24" to 30" 8' 8" 24" to 30" 24" to 30" 8' 9" 24" to 30" 24" to 30" 8' 10" 24" to 30" 24" to 30" 8' 11" 24" to 30" 24" to 30" 9' 0" 24" to 30" 24" to 30" 9' 1" 26" to 30" 24" to 30" 9' 2" 27" to 30" 24" to 30" 9' 3" 28" to 30" 24" to 30" 9' 4" 29" to 30" 24" to 30" 9' 5" 30" 24" to 30" 9' 6" 24" to 30" 24" to 30" 9' 7" 24" to 30" 24" to 30" 9' 8" 24" to 30" 24" to 30" 9' 9" 24" to 30" 24" to 30" 9' 10" 24" to 30" 24" to 30" 9' 11" 24" to 30" 24" to 30" 10' 0" 24" to 30" 24" to 30" 10' 1" 24" to 30" 24" to 30" 10' 2" 25" to 30" 24" to 30" 10' 3" 26" to 30" 25" to 30" 10' 4" 27" to 30" 26" to 30" 10' 5" 28" to 30" 27" to 30"
*Based on 36" countertop height .
Possible vented installation height*
Possible recirculating installation*
Duct cover accessory
Supplied
Accessory ZX90010
Charcoal filter replacements are available from your dealer or by calling 800.626.2002. Order catalog number WB02X11284.
ZV900SLSS duct cover dimensions
NOTE: ZX90010 accessory consists of one 40"-long duct cover.
The serial plate is located behind the removable filters.
50
Pairing hoods with cooking equipment
Monogram® hoods are designed to perfectly coordinate with Monogram ranges and cooktops. To learn which cooking products can be combined with the hood you have selected, refer to the charts below.
Wall-mounted Island Downdraft
Installation combinations
Style
Width
High speed blower rating
Sones working speed
Recirculating option
Vented duct cover options
Duct size
Equivalent duct length
ZV755SPSS ZV750SPSS ZV800SJSS ZV830SMSS ZV900SLSS ZV950SDSS
All non-pro cooktops
Chimney
36" 36" 30" 36" 36" 36" 42" 36" 36"/3 0"
490 CFM 350 CFM 460 CFM 420 CFM 490 CFM 690 CFM
10.0, 6.0 210/2.0, 170/1.1
8'–10' 8" options 8'–10' options 8'–12' options 8'–10' 5" options No 8'–10' 4" options No 8'–10' 1" options No
8' to 9' 2" duct cover included; 9" to 10' 3" duct cover optional
6" round 6" round 8" round 8" round 8" round 6" round 8" round 8" round 3-1/4" x 10" rect.
100' 100' 100 ' 100' 100' 100' 100 ' 100 ' 100'
All non-pro cooktops
Chimney (slide-out) Chimney Chimney Chimney Chimney Chimney Chimney
7.0 220/2.0
8' to 10' duct cover included; or undercabinet option
All 30" non-pro cooktops
9.0 190/2.0
7'11" to 10' duct cover included; 10' to 12' duc t cover optional
All non-pro cooktops
8.0 230/2.0
8' to 9' 5" duc t cover included; 9' 6" to 10' 5" duct cover optional
All 30" and 36" cooktops and ranges
6.0 330/1.3
8', 9' or 10' duct cover included; 10' to 14' duct cover optional
ZV855SPSS ZV850SPSS ZV1050SFSS Z V925SLSS
All non-pro cooktops
490 CFM 350 CFM 1040 CFM 490 CFM
10.0, 6.0 210/2.0, 170/1.1
8' to 8' 7" duct cover included; 9' to 10' 1" duct cover optional
All 30" and 36" cooktops and ranges
10.0 450/2.5
8'1" duct cover included, 8'2 " or 10' duct cover optional
All non-pro cooktops
8.0 230/2.0
8' to 9' duct cover included; 9' 1" to 10' 1" duct cover optional
ZVB36STSS ZVB30STSS
All non-pro cooktops
Telescopic downdraft
390 CFM
10.5 170/2.5
Indoor remote blower option
Professional wall-mounted Professional island Wall or island hood inserts ZV48TSFSS
ZV36TSFSS
Installation combinations
Style
Width
Blower rating
Sones working speed
Recirculating option
Vented duct cover options
Duct size
Equivalent duct length
42
Note: Cooktop or range not to exceed vent hood width
ZV30TSFSS
All Monogram cooktops and ranges
Tapered Straight Restaurant
48"/36"/30" 4 8"/36"/ 30" 48 "/36"/30" 30" 42" 54" 36"/3 0" 48"/42"
1090/620/620 CFM
13.0, 9.0 430/2.5 240/1.1
No No No Yes No No No No
Optional 6" and 12" duct covers; stackable
10" round 10" round 10" round 8" round 10" round 10" round 8" round 8" round
150' 150' 150' 100' 150' 150' 100' 100'
ZV48SSFSS ZV36SSFSS ZV30SSFSS
All Monogram cooktops and ranges
1090/620/620 CFM
13.0, 9.0 430/2.5 240/1.1
Optional 6" and 12" duct covers, standard or full-width; stackable
ZV48RSFSS ZV36RSFSS ZV30RSFSS ZV30HSRSS ZV42ISHSS ZV54ISHSS
All Monogram cooktops and ranges
1090/620/620 CFM 530 CFM 1090 CFM 1090 CFM 640 CFM 1140 CFM
13.0, 9.0 430/2.5 240/1.1
Optional 6" and 12" duct covers, standard or full-width; stackable
All Monogram 30" cooktops and ranges
Wall-mounted/ undercabinet Tapered Tape red Insert Insert
9.0 240/2.0
3-1/2 risers with and without louvers included
All 30" and 36" cooktops
13.0 430/2.5
7'11" to 8'5" duct cover included, 8'6" to 10'4" duct cover optional
All Monogram cooktops and ranges
13.0 430/2.5
7'11" to 8'5" duct cover included, 8'6" to 10'4" duct cover optional N/A N/A
ZVC36LSS ZVC30LSS
All 30" and 36" cooktops and ranges
14.0 250/3.5
ZVC48LSS ZVC42LSS
All Monogram cooktops and ranges
16.5 490/4.0
The Home Ventilating Institute (HVI) is a third-party certification organization focused on providing a fair and credible method of comparing ventilation performance of similar products. Many agencies such as ENERGY STAR
®
and ASHRAE utilize HVI certification for performance assurance. All Monogram ventilation products are certified by HVI.
Some key performance criteria measured by HVI are sound level measured in sones, high speed and working speed measured in cubic feet per minute (cfm).
A sone is an internationally recognized measurement of sound output. Sones translate decibel ratings into numbers that correspond to the way people sense loudness. The lower the sone number the quieter the sound.
Working speed is defined as the speed that produces 100 cfm, or the lowest speed above 100 cfm that a hood can produce, when working on the same duct system as the maximum speed.
(HVI916, March 1, 2009) (http://hvi.org/faqs.html)
monogram.com
Chimney hoods
Professional hoodsCustom hood insertsTelescopic
downdraft vents
43
Loading...