Page 2
BEFORE YOU BEGIN
Read these instructions completely mid carefully.
IMPORTANT- Sa,'etheseinstructionsfl,r
local inspector's use.
IMPORTANT Obser,'eangoverningcodes
and ordinances.
Note to Installer- Be sure to leave these instructions with the (_onsumer.
Note to Consumer - Keep these instructions tor
flffm'e reference.
Skill Level - Installation of this vent hood requires
basic mechanical and electrical skills.
Completion time - I to 3 horn's.
Proper installation is the responsibility of the installer.
Product thilure due to improper installation is not
covered under the Warrai"ttv.
CAUTION:
Due to the x_eight and size of this xent hood and to reduce the risk. ofp ,ersonaliniurv. , or damag*e to the product, we recommend at least three people install this
hood.
PRUDENCE
._ cause du poids et de la taille de la hotte et pore"
rOduire les risques de blessures ou de dommages de 1'&l uipement, nous recommandons que trois personnes
installent cette hotte,
WARNING:
To reduce the risk of fire or electrical shock, do not use this range hood with any external solid-state speed
control device. Any such alteration fl'om original tactorv
wiring could result in damage to the trait and/or create
an electrical safety hazard.
ADVERTISSEMENT
Pore" r_duire le risque d'incendie ou de choc _lectrique, il ne fluff pas utiliser cette hotte avec tm r_gulatem" de vitesse _lectronique externe. Toute modification de ce type du branchement d'usine peute endommager l'appareil ou crier tm risque de choc _lectrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PER.SONS, OBSERVE THE
FOLLOWING:
A. Use this refit only in the rammer intended bv the
manulhctm'er. If you have any questions, contact the
Illan/lt_l ct/lr er,
B. Before servicing or cleaning trait, switch power otI at
the service panel and lock service panel to prevent power fl'om being switched on accidentallv. If the service panel calmot be locked, fasten a tag or pronfii_ent warlfing label to the panel.
ADVERTISSEMENT
POUR R]_DUIRE LE RISQUE D'INCENDIE, DE CHOC ]_LECTRIQUE OU DE BLESSURES, IL FAUT
OBSERVER LES REGLES SUIVANTES:
A. Lltiliser cet appareil tmiquement de la mani_re
pr_vue par le tabricant. En cas de question, consulter le tabricant.
B. Avant toute intervention ou nettoyage, couper
l'alimentation _lectrique au disjonctem" et verrouiller le pmmeau du disjonctem" pore" _viter la raise sous tension accidentelle. S'il n'est pas possible de verrouiller le pmmeau du disconcteur, attacher un placard ou tree _tiquette tres visible au pmmeau.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors.
Structural fl'anfing, installation work and electrical
wiring must be done by qualified person (s). In
accordance with all applicable codes and standards illcluding fire-rated coi_struction.
Sulticient air is needed for proper combustioi_ aim exhausting of gases through the flue (chimney) of tirol bm'ning equipment to prevent back drafting. Follow the heating equipment mmmlhctm'er's guideline and satetv standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refl'igeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
Local codes vary. Installation electrical com_ections and grotmding inust comply with applicable codes. In
the absence of local codes, the vent should be in- stalled in accordance with National Electrical Code
ANSI/NFPA 70-1990 or latest edition.
CAUTION: T,, reduce risk of fire and to
properly exhaust air, be sm'e to duct air outside - Do not xent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
rlDH r'lr- lllt_r-
rnvijr i _l_,rll taut prendre soin d'installer
un conduit vers l'ext_riem" pour r_duire le risque d'incendie et pouwfir _vacuer l'air correctement, ll ne thut pas &vacuer l'air correctement. I1 ne thut pas _vacuer l'air dan s l'espace entre les patois d'tm tour, un plaflmd ou tm grenier, tm espace sanitaire ou tm
garage.
2
Page 3
CONTENTS
Design Information
Product Dimensions ......................................................... 3
Duct Cover Accessories .................................................... 3
Product Clearances .......................................................... 3
Advance PImming
Tools and Materials Required .......................................... 4
Power Supply .................................................................... 4
Duct Fittings ...................................................................... 5
Installation Instructions
Step 1, Plan the location,
Ceiling Support Structure ...................................... 6
Ductwork ................................................................. 7
Step 2, Remove Packaging ............................................... 8
Step 3, Check Installation Hardware ............................... 8
Step 4, Mount Template ................................................... 9
Step 5, Install Support Frame .......................................... 9
Step 6, Secm'e Wiring ..................................................... l 0
Step 7, Size and Install Ductwork .................................. 10
Step 8, Install Decorative Duct Covers .......................... l l
Step 9, Install Hood ........................................................ 11
Step l 0, Comaect Electrical ............................................ 12
Step l l, Slide Duct Cover Down .................................... 12
Step 12, Install filters, Finalize Installation ................... 13
PRODUCT DIMENSIONS
This xent hood is designed to be used in xented ceiling motmted installations.
_Height
to Ceiling
_ 10"
* 20"to an 8ft. ceiling. Usingsupplied duct cover
32" for 9 ft. Ceiling. UsingZX1059SFSSAccessory
44"for 10ft. Ceiling UsingZX10510SFSSAccessory
This xent hood is supplied with a decoratix e duct coxer to
reach 8 ft. ceiling height, or bet_xeen 7' 11" and 8' 1".
PRODUCT CLEARANCES
The vent hood must be installed 25-1/2" rain. and 30"
max. above the cooking stlrlhce. 30" is recommended t()r S t[, ceilings. 30" clearance will insure that the duct cover meets the ceiling. The cooking smthce should be
at least 36" above the floor. Installation will be easier if the vent hood is installed betore the cooktop and
cotmtertop is installed.
.... [] .... [
*30"
Recommended
I
o
36"Min.
I
DUCT COVER ACCESSORIES
Order Accessorv duct covers tor 9 ft. and 10 ft. ceilings. ZX1059SFSS - For 9 tL ceiling height
This kit includes a decorative duct cover and support
fl'ame to reach a 9 fl ceiling height. ZX10510SFSS - For 10 ft. ceiling height
This kit includes a decorative duct cover and support
fl'ame to reach a ]0 fl ceiling height. Order the accessorv at the same time as the vent hood
and have on site before installation begins.
"9 ft. to 10 ft. ceilings may be 25-1/2" to 30" clearance.
*The distance between the cooking surface and the bottom of the
hood must beat least 25-1/2".The 30"recommended installation height, abovethe standard 36" countertop, will insure duct cover fit
tothe ceiling. For 9ft and 10ft. ceilings, the hood may be lowered to
25-1/2"over the cooking surface. IMPORTANT: Clearances mayvary due to type of cooking product and local codes. Check with local inspectors to besure standard is applicable.
-When installing the Island Hood above a Monogram Professional Rangeor Cooktop,installation clearance must be at least 30".
3
Page 4
Advance Planning
TOOLS AND MATERIALS REQUIRED
(not supplied)
Tapemeasure
Knife
Spirit level
Wire cutter
Wire stripper
Wire nuts
Electric drill and 5/32" bit
Phillips screwdriver
Flat blade screwdriver
Hammer
Pliers
Safety glasses
Tape to mount template
Glovesto protect against sharp edges
120V60Hz.15or20Amp, 2wire with ground. Properly grounded branch circuit.
Strain relief for junction cover.
Plumb
Center punch
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING:, oR ,T.IS
APPI_I_"4 CE MUST BE PROPERI N GROUNDED.
ATrENTION- DE
SECURITE, CET APPAREIL DOlT ETRE CORRECTEMENT MIS ik LA TERRE.
Remo_,e house fl/se o1" open circuit breaker before begimdng installation.
Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prexail-
ing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120\/, 60Hz, mad
cmmected to an individual, properly grotmded branch circuit, and protected by a 15 or 20 amp circuit
breaker or time delay fllse.
Wiring must be 2 wire with grotmd.
If the electrical supply does not meet the above requirements, call a licensed electrician beti)re proceeding.
Route house wiring in the ceiling, as close to the installation location as possible. Allow an additional
3 feet length ti'om ceiling joists to reach thejtmction box on the hood.
Com)ect the wiring to the house wiring in accol'- (lance with local codes.
Grounding Instructions
The grotmding conductor must be com)ected to a
grotmd metal, permm)ent wiring system, or an equip- ment-gromMing terminal or lead on the hood.
WARNING:The improper (onnection ot
equipment-gromMing conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in (loubt whether the appliance is properly grotmded.
ADVERTISSEMENT
Le mauvais 1)ranchement du fil de raise h la terre peut causer tm choc 01ectrique. En cas de doute, consulter tm 01ectricien q ualifi0 ou tm technicien pore" d0terminer si l'appareil est h la terre.
4
Page 5
Advanced Planning
DUCT FITTINGS
Use this chart to compute maxim um
permissable lengths for duct runs to
o/Itdool's.
Note: Do not exceedmaximumpermissableequivalent lengths!
Maximum duct length: 100footfor range hoods.
Flexible ducting:
If flexible metal ducting is used, all the equivalent feet values in the table
should be doubled. The flexible metal duct should be straight and smooth
and extended as much as possible.
Do NOT use flexible plastic ducting.
Equivalent Quantity
Duct Piece Dimensions Length* Used
Round, 1 It. straight (pet fi)ot
length)
1 ft.
3-1/4" x 12" (pet" foot straight length)
90 ° elbow 15 It.
4._° elbow 9 It.
3-1/4" x 12" 90 ° elbow 15 ti.
3-1/4" x 12" 45 ° elbow 9 ft.
3-1/4" x 12" 90 °tlat elbow 20 ft.
S" round to
3-1/4" x 24" transition 1 It.
Total Equixalent
Length
Note: Any homeventilation system,suchasa
ventilation hood,mayinterrupttheproperflow of combustionair andexhaustrequiredbyfireplaces, gasfurnaces,gaswater I_eatersand othernaturally ventedsystems.Tominimizethechanceofinterruption
ofsuchnaturallyventedsystems,followthe heating equipmentmanufacturer'sguidelinesandsafety standardssuchasthosepublishedbyNFPAandASHRAE.
3-1/4" x 12" to 8" round transition 5 1_.
_ _" lonnd
_ 3-1/4" x 12" to 8"
_' ,vith damper 30ft.
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineer-
ing and reflect requirements for good venting performance with any ventilation hood.
to 3-1,/4" x 12" transition 90 ° elbow 5 ft.
round transition 90 ° elbow IBft.
Round wall cap
with damper 30 ft. 3-1/4" x 12" wall cap
Round roof cap 26 ti.
Round roof vent 24 It.
Total Duct Run
5
Page 6
Installation Instructions
[STEP 1]ADVANCE PLANNING
Plan the location Determine the exact location of the vent hood.
Use a plumb bob to check location to be sure countertop/cooktop location below the hood will align exactly,
The hood should project tin'ward l-I/2" beyond the
fl'ont edge of the cooking appliance. See illustration.
Observe the recommended space (30") betweei'J the cooking surtace and bottom of hood.
Ceiling support structure
At the hood location, install 2 x 4 rain, cross fi'aming between ceiling joists as shown. (2x4's are required to
support the weight,)
The 2 x 4 cross fl'aming can be installed standing or flat, depending on duct i'/in. See illustration.
Ceiling
I ! [Hood
I i_Ducting
Front \
Hood
i i
_31-1/2" i
I I
_ Countertop
SideView
K
11-1/4" i
TopView ofSupportFraming
Cross
Framing ,
i
t
"7-1/4"
i i
TypicalSupportFrameMounting
*The framing should be spaced 7-1/4"on the sides
and 11-1/4"at the front centerline to accept mounting screws inthe vent support frame.
i i i i
Cross
i i i i
i,
i i
,_7-1/4"_;
Ceiling
i,
i i
i i i i i i
i
i i
Frontof(4P
Hood
Side
View
\
Upper "_ Support
Frames
Lower /
IMPORTANT: The cross framing must be spaced 7-1/4"
from centerline to centerline in order to accept the hood mounting screws.
6
Page 7
Installation Instructions
[STEP 11CONTINUED
Arrange cross fl'aming in the ceiling to suit the existing structure. See examples.
- Secure each 2 x 4 block with at least four (4), #10 wood screws, 3" hmg (not supplied). Use 8 wood
screws total for the two supports.
The cross framing must be accurately aligned to assure correct positioning of the hood.
The cross framing must be level in all directions.
Check with a spirit level and a(!just if necessary.
IMPORTANT: The ceiling structure mustbe capable of supporting the weight of the hood (approximately 300 pounds) and
any inadvertent user contact loads.Thehood support frame will be supported bythe 2x 4 min. cross framing.
2x4 Min.
CrossFraming
0- Ii i
Ceil _7-1/4_
Joist 11-1/4'-_'_"
UpperHalf- Opening
OfSupport
Frame
i i
Support Frame
'-Height
Adjustment
Slot
Ductwork
Use the shortest and straightest duct route possible. For satist, mtory pertormance, duct run should not exceed 100 feet equivalent length tor any duct configuration.
Reter to "Duct Fittings" chart to compute the maxi- mum permissible length for duct runs to the out-
doors.
This vent hood must use 8" round duct. The 8" round duct can transition to 3-1/4" x 12".
Install the house ductwork to run horizontally between ceiling.joists or straight up through the roof.
Finish the Ceiling
Finish the ceiling surtace. Be sure to mark location of the ceiling.joists and cross fl'aming. Check to be sure the ceiling is level, use shims if necessary.
VentStraight Up
ThroughTheCeiling
Flat
*Depending on available space.
CeilingJoint
//
2x4
8"Round
Standing
*Vent Between
Ceiling Joists
Page 8
Installation Instructions
ISTEP21REMOVE THE PACKAGING
The vent hood is packed separate fl'mn the decorative
duct cover or accessory co','ers ZX 1059SFSS or ZX10510SFSS.
Remove the ti'ame, covei, parts box and packaging.
Remove junction box cover.
Install strain relief onto junction box cover.
[STEP 3] CHECK INSTALLATION HARDWARE
Locate the hardware accessory pack shipped x_ith the
hood and check contents.
3Phillips head decorative screws
4Machine Screws
4>
4Lock Washers
StopScrew
Service Safety
Check service manual envelope taped to the side of
the hood to he sure it contains one stop screw,
Leave this screw in the envelope,
Check contents of the accessory package.
Support frames with 8screws ____
and8 washers _ .... _-
4Hex Head LagScrews
MountingScrewHoles
Template
4Filters
Decorate Duct Covers
1
ScrewHole(LeftSide)
8
Page 9
Installation Instruction
[STEP 4] MOUNT TEMPLATE
Align the template with the marks on the ceiling and tape in place.
- Be sure the template is oriented correctly, with the
flxmt of the hood.
Use a plumb to check to be sure the mounting holes
will provide parallel aligmnent with the cotmtertop
below.
Center ptmch all hole locations.
Drill pilot holes in the 4 screw locations. Use a 5/39" bit and drill approximately 1-1/9" deep.
Cut the 8-1/4" duct opening and approx. 1" wire access hole.
[STEP INSTALL SUPPORT FRAME
Wire Holes
°°{.l_ing_ LowerSupport
L
Upper/I
Support Fron
Frame Of
Lower
Support
Frame
Install upper support frame
Secm'e the upper support fl'ame to the ceiling.joists and cross flaming with the 4 lag screws provided. For maximmn rigidity and strength, the screws must be driven into the center of the joists and/or cross flaming.
Check to be sure the support frame is level, vertically and horizontally.
Hoo(
Support
Frame
Opening
BothDirection
30"Recommended
76"
Countertop
V--
Install lower support frame
lllsert lower support fl'alne (or accessory support fl'ame, ZX1059SFSS or ZX10510SFSS) into the tipper support fralue aim loosely secure with 8 screws aim
washers. (4 on the fl'ont and 4 on the back sides)
At!just the lower support fl'ame up or down to the desired height above the cotmtertop. Tighten screws.
IMPORTANT: Again, check to be sure the support is
lexel in both directions. There is no way to lexel the hood after the hood is secm'ed to the fl'ame.
9
Page 10
Installation Instructions
ISTEP 61 SECURE WIRING
Route house wiring through the ceiling hole and
pull a length to reach the hood junction box, approximately 6" below the support.
fy,ing
View
Support
Frames
_______Tape
House
-_ Wiring
Tape the _dre to the left side of the fl'ame support to pre_ent damage during installation
aI'ld ser',ice,
ISTEP71SIZE AND INSTALL
DUCTWORK
Side
View
Support
Frame
DuctConnection ToHood
Dim.A Length
T
BottomSupport
FrameFlange
Measure fl'om house duct flange to bottom of support fl'ame. Dim. A
- Add at least l" fl)r duct overlap at the top.
- Subtract 1-3/4" for hood insertion into the bottom
of the fl'ame to determine required duct length.
Cut the 8" duct length required.
Note: The bottom of the duct must be external (female) c(mnecti(m to the top of the hood. The b()ttom end
sh(mld be flared slightl> to tacilitate installation of the hood.
Install duct tip through support fl'ames and attach to house ducting with sheet metal screws.
Seal the c(mnection with duct tape.
Re red
Duct Duct
10
Page 11
Installation Instructions
ISTEP 81INSTALL DECORATIVE DUCT COVERS
InstallScrewon
EachSide
Pretap
2Screw
Holes_
(One
On
Each
Side)
/
/
Pretap or drive decorative screw into the screw holes on the support frame. This will make screw installa-
tion easier.
Separate the two decorative duct covers.
Select the inside cover (top), which has two screw holes in the top.
Slide the decorative duct cover over the support fl'ame and push to the ceiling.
Attach to the hood support at the top with 2 supplied decorative screws.
Locate the 3rcl decorative screw in the hardware package. Set aside.
Bottom Duct Cover
Bottom Duct
Install Stop Screw in Hole
\
Slide the lower decorative duct over the installed upper duct and push to the top, keeping the bottom
slotted hole to the left.
Install the decorative stop screw in center hole of upper (imaer) duct cover. The decorative screw will act as a stop screw and prevent the lower decorative duct
covet" frot/t sliding down.
of Upper (Inner) Duct Cover
CAUTION:Thest,,ps,-re,,,m.st'.ei.stalle(l
Failure to do so could result in personal it_jury or damage to the duct cover.
PRUDENCE- I_a ,is sup_rieure d(,it _tre eta
place, afin d'_viter les blessures ou (l'etadommager l e capot antipoussi_re,
I STEP 91INSTALL HOOD
Note: AT LEAST THREE PEOPLE ARE REQUIRED TO COMPLETE THIS INSTALLATION!
Lift the hood up to the support fl'ame. Carefltllv align the hood mounting holes to support fl'ame
holes, and at the same time, the hood duct c(mnector into the duct.
Install screws through the hood and hood support.
Check hood level in both directions.
Check to be sure that the duct is positioned ()vet" the 11oo(1 coiaiaector,
Seal the duct comaection with duct tape,
Note: Do not drive screws through this duct comaec- tion. Doing so _ill prexent proper damper operation.
11
Bottom
Duct Screw
Cover
Install
4 LockWashers
and4 MachineBolts
ApplyDuctTape
-- to SealDuct
f.._ Connection
Page 12
Installation Instructions
ISTEP101CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING:. ,,.,,se,,iri, gisn.t>,ire,,,,
a grotmd wire, a grotmd must be provided bv the installer. When house wiring is almninmn, be sm'e
to use UL approved anti-oxidant compotmd and
_lh,II/iI_ HIll -t o-copper coi_nectors,
ATTENTION- le c_iblage de la maison
n'est pas du type h deux ills avec tm fil de terre, l'installatem" dolt fimr,air t,,a circuit de terre. Quand les
ills de la maison sont en aluminium, il prendre soin d'utiliser de la pfite antioxidation approuv_e par UL et
des cmmectem's pore" l'aluminium-cuivre.
Install strain relief onto the knockout of thejm_ction
box cover.
Insert house wiring through strain relief and tighten.
Comaect white leads to branch circuit white lead.
Comaect black leads to branch circuit black lead.
Comaect green/yellow leads to branch circuit green or bare grotmd lead.
Secm'e all comaections with wire nuts on each electrical coiln ector.
Push wires into junction box and replace cove,'. Be sm'e wires are not pinched.
ISTEP 111 SLIDE DUCT COVER DOWN
hstaH
Decorative
Screw
Hold the decorative duct c{we," and remove the decorative stop screw fl'om the support fl'ame.
Keep the screw.
Slide the lower duct cover down onto the hood.
Install the decorative screw in the lower left hole on the duct cover as shown.
12
Page 13
Installation Instructions
ISTEP 121INSTALL FILTERS, FINALIZE INSTALLATION
Filter Slots
Remove protective fihn on the filters.
Tip the filter into the lower slots at the rear of the
opening. Liti the filter and pull the knob tin'ward until the filter rests on the slots.
To remove the filters, grasp the knob and push the filter towards the rear and tilt downwards.
Remove the protective fihn covering the control panel on the fi'ont time of the hood, and any other packaging materials.
Check all 4 lamps to assm'e tightness in sockets.
Refer to the Owner's Mamlal for operating instructions.
Clean the hood with an approved stainless steel cleaner.
13
Page 14
Notes
14
Page 15
Notes
15
Page 16
Pub.No.49-80153 Dwg.No.164D4290P110
(N.D.538) 11/02
Printed inItaly
Note: While performing installations described inthis book, safety glasses or goggles should be worn.
k)Jr Mo_og'r_m _ lo_d _vice i_ )our _lre_, c_ll
1-800-444-1845.
Note: Product improvement is a COlltilluing endeavor at (;eneral Electric. Theref_)re, materials, appearaJlce and specifications arc" subject to change without notice.
Monogram:
Webringgoodthingstolife.
General Electric Company Louisville, KY40225
Loading...