GE ZISB360DM User Manual

Monogram.
ZISB360DM – GE Monogram 36" Built-In Refrigerator
with Dispenser and Water Filter
35-1/2
7"
5"
83 1/2" min
Finished Opening
74" From Floor
to Bottom
of Electrical
24"
5"
5"
3 1/2"
Water Supply
3 1/2"
36" Models 12"
THE INSTALLATION SPACE
*84" From Floor to Top Frame
36"
Frame to Frame
35"
Case Width
at
Rear
*Shipping height.
The refrigerator can be adjusted to fit into a cutout that is 83-1/2" min. to 84-1/2" max. height. Note that the top case trim at the front is 1/2" higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for height adjustment.
As an ENERGY STAR® Partner,
GE has determined that this product
meets the ENERGY STAR®
guidelines for energy efficiency.
15"
13"
23-7/8" Behind Frame
20-5/8
Product Clearances
These refrigerators are equipped with a 2 position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.
Allow minimum clearances for freezer door and fresh food door for a full 130° door swing and to allow for pan removal.
4" minimum clearance is required when door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.
Water And Electrical Locations
The opening must be prepared with the electrical and water supply located as shown.
The cutout depth must be 24".
Designed for industry standard flush installation. The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.
The cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed the 24" installation depth shown. The top case trim overlaps the bottom of the soffit.
Frameless cabinets:
The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips.
Additional Specifications
A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
Water line can enter the opening through the floor or back wall. The water line should be 1/4" O.D. copper tubing between the cold water line and water connection location, long enough to extend to the front of the refrigerator. Installation of an easily accessible shut off valve in the water line is recommended.
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
R
Listed by Underwriters Laboratories
Specification Revised 8/02
Monogram.
ZISB360DM – GE Monogram 36" Built-In Refrigerator
with Dispenser and Water Filter
1/4" FRAMED PANEL DIMENSIONS
If you choose to install framed panels, they must be cut to the dimensions shown. The panels will slide into the frame on the door and grille.
Non-Dispenser Models
If the custom panel is less than 1/4" thick and it fits loosely in the door frame it can be backed up with a piece of filler material or foam tape to improve the fit.
1/4"
Panel
Door
5/16"
Trim
Reveal
IMPORTANT NOTE: Maximum weight for fresh food panel is 50 pounds and 30 pounds for freezer panel.
IMPORTANT NOTE – Dispenser Models
The refrigerator is supplied with two dispenser trims, one for framed panels and one for overlay panels.
If the panel is less than 0.250" thick a noticeable gap may be created around the dispenser trim. Foam tape may be applied on the door to improve the fit.
If the panel is more than 0.250" thick, the dispenser trim cannot be secured to the door.
Fresh Food
Panel
Freezer
Panel
18-9/16
14-9/16
33-7/8
9
Grille Panel
68-3/8
9-5/8"
Dispenser Cutout
15-3/8"
The framed panel must be 1/4" nominal thickness to fit the dispenser trim.
SIDE PANELS
Side panels must be used whenever the sides of the refrigerator will be exposed. The 1/4" side panels will slip into the side case trim. Order the side panels from the cabinet manufacturer.
* Depending on installation height.
*84"
2-9/16"
24"
*3" to 4"
As an ENERGY STAR® Partner,
GE has determined that this product
meets the ENERGY STAR®
guidelines for energy efficiency.
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
R
Listed by Underwriters Laboratories
Specification Revised 8/02
Loading...