A 115 volt 60Hz., 15 or 20 amp power supply
is required. An inidividual properly grounded
branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical
receptacle recessed into the back wall.
*3"
(7.6)
* Shipping height . Use leveling legs and wheels for maximum
1" height adjustment from shipping height.
35" (89.0)
Case width
** Allow 25" (63.5) min
clearance for 130˚
door swing
TOP VIEW
*3 1/4"
(8.3)
SIDE VIEWFRONT VIEW
36 3/4"
(93.4)
** Allow
4" (10.2) min
clearance to a wall
for 90˚ door swing
**These units are equipped with a 2-position door stop. The factory set 130° door swing can
be adjusted to 90° if clearance to adjacent cabinets or walls is restricted. Allow 15" minimum
clearance to wall for pan removal. If the 90˚ door stop position is used, pan access is
maintained but pan removal is restricted.
Dimensions in parentheses are in centimeters unless otherwise noted.
Actual product dimension may vary due to manufacturing tolerances.
box in this location will
also allow for front
accessability through
access panel.
B
Water supply area.
WARNING:
The refrigerator is top
heavy and must be secured
to prevent the possibility of
tipping forward. Failure to
do so may result in death
or serious injury.
The information below is
for cabinet design only.
When installing the antitip system you must use
the product installation
instructions.
The information below
applies to all installation
constructions:
• A wall bracket, bolts and
toggles will be supplied
with the unit.
• The bolts will be used to
attach bracket to wall in
4 locations. Two of the
locations must penetrate
the center of the wall
studs.
• The toggles are used for
stability in drywall and
when metal studs are
encountered. Lag bolts
are used in wood studs.
• In installation opening,
measure 81 ½” from
floor and draw a
horizontal line.
• Locate and mark the wall
studs on horizontal line.
Verify at least two studs
have their centerlines
within the center 32.5”
of installation opening to
ensure 2 wall studs are
penetrated.
• The bracket will be
centered left to right in
opening with bottom of
bracket on the horizontal
line.
• When unit is placed in
opening, the bracket tabs
will align with openings
in back of the unit. The
unit will be secured to the
bracket using supplied
“L” bolts.
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
See Installation
Instructions for detailed
instructions.
used whenever the sides
of the refrigerator will
be exposed. The 1/4”
side panels will slip
into the side case trim.
Secure the panels to
the refrigerator with
stick-on hook and loop
fastener strips. Order
the side panels from the
cabinet manufacturer.
Additional cutout width may be required when
side panels are used.
B
In a side-by-side installation of a left-
and-right-hand door swing product, 1”
clearance between the units is required.
Order ZUGSS2 European, ZUGPP2
Professional or ZUG2 custom panel unified
grille kit for one continuous grille panel.
C
In a side-by-side installation with same
door swing, allow 2” minimum clearance
between the products to prevent the door
swing interference. Allow 15” minimum
to a wall to achieve full drawer extension
and pan removal. Additional clearances
are required when using custom panels
and handles.
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille
panel kits will not fit this installation.
3 1/2"
(8.9)
W
D
In a side-by-side installation with right
and left door hinges together, allow 5”
minimum clearance between the two
products to prevent one door from striking
the other. Additional clearances required
when using custom panels and handles.
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille
panel kits will not fit this installation.
Trimmed refrigerators are designed to be
customized with decorative panels. Fieldinstalled custom door and grille panels are
required.
1/4” Framed Panels:
You may install 1/4"- thick custom panels from
your cabinet manufacturer. The decorative
panels slide into the factory- installed trim.
Maximum total panel weight:
• Door panel – 67 lbs.
• Grille panel – 11 lbs
3/4" OVERLAY PANEL DIMENSIONS
PANEL ASSEMBLY CROSS SECTION
1/4" Backer Panel
.10" Spacer Panel
PANEL DIMENSIONS
1/4" Backer Panel
.10" Spacer Panel
3/4" Overlay Panel
.25" + .10" + .75" = 1.10" Total Panel Thickness
Grille Panel
A
Door
Panel
B
C
Trim
ABC
33 7/8"8 7/8"69 5/16"
32 1/2"7 5/8" 67 15/16"
34 1/8"9"69 9/16"
Door
3/4" Overlay Panel
Supplied Handles
3/4” Overlay Panels:
For a more custom appearance, overlay
panels may be installed on trimmed models.
The overlay panel must be secured to a
1/4"-thick backer panel which slides into
the trim. A spacer panel 0.10" thick must
be placed between the overlay and backer
panels.
Center each panel over the other. Assemble
the panels with glue and screws. Screws must
be countersunk into the backer panel.
NOTE: Left-to-right offset is not always equal
to top-to-bottom offset.
Maximum total panel weight:
• Door panel – 67 lbs.
• Grille panel – 11 lbs
Door Handles:
The supplied handles can be adjusted to
accommodate both framed or overlay panels.
Custom handles of your choice, supplied by
your cabinet maker, can also be installed.
ZKHPSS1: Professional Tubular Stainless Steel
Handle designed to fit 3/4" overlay panels.
Kits include one handle - 30 1/2" long.
ZKHSS2: European tubular stainless steel
handle designed to fit 3/4" overlay panels.
Kits include one handle - 64 1/4" long.
Product Specification Created 3/14
Page 6
FEATURES AND BENEFITS
Custom Panel Model - Can be personalized with
cabinet-matching panels and handles
Enhanced Temperature Management System With precise electronic controls and thermistors,
maintains ideal storage conditions for fresh foods
Concealed Halogen Lighting System Illuminates contents without compromising space
®
ENERGY STAR
Qualification - As an ENERGY
STAR® partner, GE has determined that Monogram
all-refrigerators meet the ENERGY STAR®
guidelines for energy efficiency
Humidity-Controlled Compartments and
Sealed Snack Drawers - Help preserve the