** Allow 17" (43.2) min
clearance for 115˚
door swing
(8.6)
*83 1/2"
(212.1)
†
†
FRONT VIEW
* Shipping height . Use leveling legs and wheels for maximum 1" height
adjustment from shipping height. Nominal installation height is 84”
35" (89.0)
Case width
† Dimensions include 3/4" custom cabinet panel
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply
is required. An inidividual properly grounded
branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical
receptacle recessed into the back wall.
TOP VIEW
38 3/4"
(98.4)
** Allow 4" (10.2) min
clearance to a wall
for 90˚ door swing
** These refrigerators are equipped with a 2-position door stop. The factory-set 115° door
swing can be adjusted to 90° if clearances to adjacent cabinets or walls is restricted. Allow
a 15" minimum clearance to wall for pan removal. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
Dimensions in parentheses are in centimeters unless otherwise noted.
Actual product dimensions may vary due to manufacturing tolerances.
box in this location will
also allow for front
accessability through
access panel.
B
Water supply area.
WARNING:
The refrigerator is top
heavy and must be secured
to prevent the possibility of
tipping forward. Failure to
do so may result in death
or serious injury.
The information below is
for cabinet design only.
When installing the antitip system you must use
the product installation
instructions.
The information below
applies to all installation
constructions:
• A wall bracket, bolts and
toggles will be supplied
with the unit.
• The bolts will be used to
attach bracket to wall in
4 locations. Two of the
locations must penetrate
the center of the wall
studs.
• The toggles are used for
stability in drywall and
when metal studs are
encountered. Lag bolts
are used in wood studs.
• In installation opening,
measure 81 ½” from
floor and draw a
horizontal line.
• Locate and mark the wall
studs on horizontal line.
Verify at least two studs
have their centerlines
within the center 32.5”
of installation opening to
ensure 2 wall studs are
penetrated.
• The bracket will be
centered left to right in
opening with bottom of
bracket on the horizontal
line.
• When unit is placed in
opening, the bracket tabs
will align with openings
in back of the unit. The
unit will be secured to the
bracket using supplied
“L” bolts.
See Installation
Instructions for detailed
instructions.
right-hand door swing product, 1 1/2”
clearance between the units is required.
Order ZUGF2H custom panel unified grille
kit for this installation.
C
In a side-by-side installation with same
door swing, allow 4” clearance between
the products to prevent the door swing
interference. Allow 15” minimum to a wall
to achieve full interior drawer extension
and pan removal. Additional clearances
are required when using custom panels
and handles.
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel
kits will not fit this installation.
3 1/2"
(8.9)
W
D
In a side-by-side installation with right
and left door hinges together, allow 5”
minimum clearance between the two
products to prevent one door from striking
the other. Additional clearances required
when using custom panels and handles.
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel
kits will not fit this installation.
* Shipping height. Use leveling legs and wheels for maximum 1" height adjustment from shipping height.
SPECIFICATIONS
Overall Width36" (91.4 cm)
Overall Height84" (213.4 cm)
Overall Depth25 3/8" (64.45 cm)
Door Clearance36 3/4" (93.4 cm)
Cutout Width35 1/2" (90.2 cm)
Cutout Height83 1/2" - 84 1/2"
(212.1 - 214.6 cm)
Cutout Depth24" (61 cm)
Plumbing Requirements1/4" OD copper
tubing or GE
SmartConnect kit
Shipping Weight569 lb
OVERALL DIMENSIONS
36" (91.5)
69 5/8"
(176.8)
*3"
(7.6)
* Shipping height . Use leveling legs and wheels for maximum
1" height adjustment from shipping height.
Case width
(89.0)
*73 1/4"
(186.1)
STANDARD INSTALLATION
25 1/8"(63.8)
23 7/8" (60.7)
1 7/8"
(4.8)
*84"
(213.4)
*83 1/2"
(212.1)
*3 1/4"
** Allow
25" (63.5) min
clearance for 130˚
door swing
(8.3)
SIDE VIEWFRONT VIEW
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply
is required. An inidividual properly grounded
branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical
receptacle recessed into the back wall.
36 3/4"
TOP VIEW
(93.4)
** Allow 4" (10.2) min
clearance to a wall
for 90˚ door swing
**These units are equipped with a 2-position door stop. The factory set 130° door swing can
be adjusted to 90° if clearance to adjacent cabinets or walls is restricted. Allow 15" minimum
clearance to wall for pan removal. If the 90˚ door stop position is used, pan access is
maintained but pan removal is restricted.
Dimensions in parentheses are in centimeters unless otherwise noted.
Actual product dimension may vary due to manufacturing tolerances.
box in this location will
also allow for front
accessability through
access panel.
B
Water supply area.
WARNING:
The refrigerator is top
heavy and must be secured
to prevent the possibility of
tipping forward. Failure to
do so may result in death
or serious injury.
The information below is
for cabinet design only.
When installing the antitip system you must use
the product installation
instructions.
The information below
applies to all installation
constructions:
• A wall bracket, bolts and
toggles will be supplied
with the unit.
• The bolts will be used to
attach bracket to wall in
4 locations. Two of the
locations must penetrate
the center of the wall
studs.
• The toggles are used for
stability in drywall and
when metal studs are
encountered. Lag bolts
are used in wood studs.
• In installation opening,
measure 81 ½” from
floor and draw a
horizontal line.
• Locate and mark the wall
studs on horizontal line.
Verify at least two studs
have their centerlines
within the center 32.5”
of installation opening to
ensure 2 wall studs are
penetrated.
• The bracket will be
centered left to right in
opening with bottom of
bracket on the horizontal
line.
• When unit is placed in
opening, the bracket tabs
will align with openings
in back of the unit. The
unit will be secured to the
bracket using supplied
“L” bolts.
See Installation
Instructions for detailed
instructions.
used whenever the sides
of the refrigerator will
be exposed. The 1/4”
side panels will slip
into the side case trim.
Secure the panels to
the refrigerator with
stick-on hook and loop
fastener strips. Order
the side panels from the
cabinet manufacturer.
Trimmed refrigerators are designed to be
customized with decorative panels. Fieldinstalled custom door and grille panels are
required.
1/4” Framed Panels:
Order trim kit #ZTK36SDHRH
for 1/4" thick custom panels ordered from
your cabinet maker. The decorative panels
slide into the trim.
Maximum total panel weight:
• Door panel – 67 lbs.
• Grille panel – 11 lbs
3/4" OVERLAY PANEL DIMENSIONS SINGLE INSTALLATION
PANEL ASSEMBLY CROSS SECTION
Trim
1/4" Backer Panel
.10" Spacer Panel
PANEL DIMENSIONS
ABC
1/4" Backer Panel
.10" Spacer Panel
3/4" Overlay Panel
.25" + .10" + .75" = 1.10" Total Panel Thickness
33 7/8"8 7/8"69 5/16"
32 1/2"7 5/8" 67 15/16"
34 1/8"9"69 9/16"
Grille Panel
Panel
A
Door
B
C
Door
3/4" Overlay Panel
Supplied Handles
3/4” Overlay Panels:
Order trim kit #ZTK36SDHRH
for 3/4" thick custom panels ordered from
your cabinet maker. The decorative panels
slide into the trim. The overlay panel must be
secured to a 1/4"-thick backer panel which
slides into the trim. A spacer panel 0.10" thick
must be placed between the overlay and
backer panels.
Center each panel over the other. Assemble
the panels with glue and screws. Screws must
be countersunk into the backer panel.
NOTE: Left-to-right offset is not always equal
to top-to-bottom offset.
Maximum total panel weight:
• Door panel – 67 lbs.
• Grille panel – 11 lbs
Door Handles:
The supplied handles can be adjusted to
accommodate both framed or overlay panels.
Custom handles of your choice, supplied by
your cabinet maker, can also be installed.
ZKHPSS1: Professional Tubular Stainless Steel
Handle designed to fit 3/4" overlay panels.
Kits include one handle - 30 1/2" long.
ZKHSS2: European tubular stainless steel
handle designed to fit 3/4" overlay panels.
Kits include one handle - 64 1/4" long.
STANDARD 1/4" FRAMED PANEL DIMENSIONS DUAL INSTALLATION
D
Door
Panel
PANEL ASSEMBLY
CROSS SECTION
A
Grille Panel
Trim
D
Door
Panel
B
C
Door
PANEL DIMENSIONS
A
B
C
D
1/4"
Framed
Panel
69 7/8"
8 7/8"
69 5/16"
33 7/8"
STANDARD INSTALLATION
NOTES
Trimmed refrigerators are designed to be
customized with decorative panels. Fieldinstalled custom door and grille panels are
required.
1/4” Framed Panels:
Order trim kit #ZTK36SDHRH
for 1/4" thick custom panels ordered from
your cabinet maker. The decorative panels
slide into the trim.
Maximum total panel weight:
• Door panel – 67 lbs.
• Grille panel – 25 lbs
Order ZUG2: Unified grille kit for dual
installation. Maximum total panel weight -
25 lbs.
STANDARD 3/4" OVERLAY PANEL DIMENSIONS DUAL INSTALLATION
PANEL DIMENSIONS
1/4"
Backer
Panel
69 7/8"68 1/2"70 1/8"
A
8 7/8"7 5/8"9"
B
69 5/16" 67 15/16" 69 9/16"
C
33 7/8"32 1/2"34 1/8"
D
.25" + .10" + .75" =
1.10" Total Panel Thickness
D
Door
Panel
PANEL ASSEMBLY
CROSS SECTION
A
Grille Panel
1/4" Backer Panel
.10" Spacer Panel
Panel
Trim
D
Door
B
C
Door
3/4" Overlay Panel
Supplied Handles
.10"
Spacer
Panel
3/4"
Overlay
Panel
3/4” Overlay Panels:
Order trim kit #ZTK36SDHRH
for 3/4" thick custom panels ordered from
your cabinet maker. The decorative panels
slide into the trim. The overlay panel must be
secured to a 1/4"-thick backer panel which
slides into the trim. A spacer panel 0.10" thick
must be placed between the overlay and
backer panels.
Center each panel over the other. Assemble
the panels with glue and screws. Screws must
be countersunk into the backer panel.
NOTE: Left-to-right offset is not always equal
to top-to-bottom offset.
Maximum total panel weight:
• Door panel – 67 lbs.
• Grille panel – 25 lbs
Order ZUG2: Unified grille kit for dual
installation. Maximum total panel weight -
25 lbs.
Door Handles:
The supplied handles can be adjusted to
accommodate both framed or overlay panels.
Custom handles of your choice, supplied by
your cabinet maker, can also be installed.
ZKHPSS1: Professional Tubular Stainless Steel
Handle designed to fit 3/4" overlay panels.
Kits include one handle - 30 1/2" long.
ZKHSS2: European tubular stainless steel
handle designed to fit 3/4" overlay panels.
Kits include one handle - 64 1/4" long.
Additional cutout width may be required when
side panels are used.
B
In a side-by-side installation of a left-
and-right-hand door swing product, 1”
clearance between the units is required.
Order ZUG2: Custom panel unified grille kit for
one continuous grille panel.
C
In a side-by-side installation with same
door swing, allow 2” minimum clearance
between the products to prevent the door
swing interference. Allow 15” minimum
to a wall to achieve full drawer extension
and pan removal. Additional clearances
are required when using custom panels
3 1/2"
(8.9)
W
15"
(38.1) min
To wall
and handles.
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel
kits will not fit this installation.
D
In a side-by-side installation with right
and left door hinges together, allow 5”
minimum clearance between the two
products to prevent one door from striking
the other. Additional clearances required
when using custom panels and handles.
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel
kits will not fit this installation.
130˚
Door swing
BC
130˚
Door swing
5" (12.7) min
D
Product Specification Revised 10/14
Page 12
FEATURES AND BENEFITS
Custom Appearance - Allows personalization
with cabinet-compatible panels an custom
handles
Upfront Electronic Controls with Digital Readout
- Allows precise temperature settings and are
positioned for maximum ease of use
Humidity Controlled Vegetable Compartments
and Sealed Snack Pans - Help maintain freshness
and help preserve foods longer
Adjustable, Spill Proof Glass Shelves - Make it
easy to customize storage to handle foods and
containers of various sizes