Monogram ZGU366NTSS Specification Sheet

Page 1
MONOGRAM 36" PROFESSIONAL GAS RANGETOP WITH 6 BURNERS
ZGU366NTSS (NATURAL GAS)
BURNER PERFORMANCE
Front Left Burner Element 23,000-BTU
Back Left Burner Element 18,000-BTU
Front Middle Burner Element 15,000-BTU
Back Middle Burner Element 15,000-BTU
Front Right Burner Element 23,000-BTU
Back Right Burner Element 18,000-BTU
VERSATILE GAS BURNER CONFIGURATION Delivering exceptional cooking flexibility, the two 23,000-BTU multi-ring brass burners and dual-stack burners offer a range of heat settings, from gentle simmer to intense fla me
RING-LIT KNOBS Delivering a modern approach to accent lighting, the rings illuminate to indica te when a burner is in use
SOLID BRASS BLADES ON PRECISION MACHINED KNOBS
With an unma tched attention to deta il, all knobs on the new Monogram Pro ra nges and ra ngetops come with solid brass accents
SEAMLESS STAINLESS TOP FRAME Meticulously crafted from one piece of sta inless steel that covers the cooktop and control pa nel, this seamless a nd stylish surface is easy to clean a nd beautiful to look a t
LP CONVERSION KIT INCLUDED Designed to deliver a sea mless conversion experience, this self­contained kit includes everything needed to convert a rangetop to liquid propane
For questions about your appliance, please call 1-800-626-2000.
PAGE 1 OF 4
Product Specication Created 12/20
Page 2
OVERALL DIMENSIONS
SPECIFICATIONS
Overall Width 35 7/8" (91.1 cm)
Overall Depth 27 1/2" (69.8 cm)
Overall Height 8 1/2" (21.6 cm)
Volts/Hertz/Amps 120v; 60Hz; 15A
Net Weight 135 lbs (61.2 kg)
Approx. Shipping Weight 163 lbs (74 kg)
ATTENTION ELECTRICIAN: Rangetops must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker or time-delay fuse.
For more details refer to the installation instructions for this product.
8-1/2" Height
35-7/8" Width
27-5/8" to Front of Bullnose
29-1/8"
To front of control knobs
27-5/8"
To front of bullnose
8"
Countertop
Level
†
Include the overhang of the rear trim when countertop continues behind the product.
The overhang is decorative only. The weight of the rangetop is fully supported by the side trims.
** Maximum countertop cutout depth from the back of the rear trim to the back edge of chamfer at the sides of the control panel - typically, the maximum countertop cutout depth (front to back). Minimum countertop cutout depth is 25-1/4"
Rear finished edge of the control panel
23-5/8"
**26-7/8"
To front of
control panel
6-1/2"
7-1/4"
8-1/2" Height
5-1/4"
To pipe
stub center
1"
1/2"
Countertop
Level
†
3/16"
11/32"
1-3/16"
For questions about your appliance, please call 1-800-626-2000.
Dimensions in parentheses a re in centimeters unless otherwise noted. Actual product dimensions may vary due to ma nufacturing tolerances.
PAGE 2 OF 4 Product Specication Created 12/20
Page 3
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA
B149.1, Current Edition). Cleara nces from non-combustible materials a re not part of the ANSI Z21.1/CSA 1.1 scope and a re not certified by CSA. Cleara nces less than 12” must be approved by local codes and/or the a uthority having jurisdiction.
UTILITY LOCATIONS
HELPFUL TIPS
PRODUCT DIMENSIONS AND CLEARANCE
A 36"- or 42"-wide professional vent hood is recommended for installation over this rangetop.
Cleara nces between rangetop and side wall must be at least 12" on each side.
Allow 8" free space below the top surface of countertop. Allow additional cleara nces below the burner box to install the regulator a nd make house gas supply connections. Use a 90° elbow to route the gas connections and limit interference with drawers or other cabinetry.
* e opening between a 4" high backsplash
must be 36" to allow the rangetop to slide back against the wall.
* *As defined in the National Fuel Gas Code
(ANSI Z223.1/CSA B149.1, Current Edition). Cleara nces from non-combustible materials are not pa rt of the ANSI Z21.1/CSA 1.1 scope and a re not certified by CSA. Clearances less than 12” must be approved by local codes a nd/ or the authority having jurisdiction.
GAS PRESSURE REGULATOR You must use the gas pressure regulator supplied with this rangetop. For proper opera tions the inlet pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6” of Water Column Maximum pressure: 13” of Water Column
Propane (LP) Gas:
Minimum pressure: 11” of Water Column Maximum pressure: 13” of Water Column
See installation instructions for more deta ils
WARNING
Installations without a hood require 48" minimum to combustibles above the rangetop. A custom hood installa tion with exposed horizontal combustible surfaces must have an "a uto-on" feature. Refer to hood installation instructions for specific hood cleara nces. e surface of the entire back wall above the countertop a nd below the hood must be covered with a non­combustible material such as metal, ceramic tile, brick, ma rble or other stone.
For questions about your appliance, please call 1-800-626-2000.
PAGE 3 OF 4 Product Specication Created 12/20
Page 4
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Rangetop
Front of deep cabinets can align with
control panel beveled edge.
Rangetop
1/2" Above Adjacent Countertops
1/2" Above Adjacent Countertops
HELPFUL TIPS
OPTIONAL BACKSPLASH ACCESSORIES
• e rangetop requires a 12" minimum cleara nce to a vertical combustible surface at the rea r. A backsplash is required for installations with less tha n 12" clearance. e following backsplash accessories are ava ilable, or a custom, non-combustible backsplash ca n be used.
• Order one with a 36"-wide ra nge backsplash:
• UX12BS36PSS–12"-height backsplash
• UXADBS36PSS–30"-36" adjustable-height
backsplash with warming shelf
Control panel projects forwards from
standard depth cabinets.
SIDE VIEW WITH A BACKSPLASH
For questions about your appliance, please call 1-800-626-2000.
PAGE 4 OF 4 Product Specication Created 12/20