General features Authentic Professional appearance.
smoothly finished edges, large electronic control knobs and heavy-duty handles.
Sealed, dual-flame stacked burners. Provide complete
low-simmer-to-rapid-boil flexibility (140°F simmer to 18,000 BTUs*). The burners are sealed to the recessed cooktop for easy cleaning.
Monogram® Professional Reverse-Air convection oven.
Provides superb baking results, with fast preheating.
Heavy-duty, full-extension racks. Glide smoothly in and
out on stainless steel ball bearings for easy access, and are designed to remain in the oven during the self-clean cycle.
LED task lights. Positioned below the bullnose, these lights
provide a functional and theatrical touch.
Electronic ignition with automatic reignition. Ensures a
continuous flame and reignites automatically if accidentally extinguished.
Reversible burner grates. These grates are flat on one
side and uniquely contoured on the other to accommodate round-bottom woks.
For additional details on product installation, warranty coverage, care and maintenance, visit monogram.com.
*Natural gas
Stainless steel with
30" Professional range
Dual-fuel: ZDP304NPSS (natural gas) and ZGP304LPSS (liquid propane) All-gas: ZDP304NRSS (natural gas) and ZGP304LRSS (liquid propane)
Overall dimensions (WxHxD in inches): 29-7/8 x 35-1/4–36 -3/4 x 26-3/4
Amps @240VAC 26 208VAC 22 KW Rating
@240VAC 6.1 208VAC 4.6 Approx. shipping wt. (lbs.) 425
Professional ranges are available in both
a dual-fuel and all-gas model
Dual-fuel or all-gas range must be specified by model number
Natural or LP gas must be specified by
model number
Optional 12" or 30"–36" adjustable-height
backsplash accessories
All burner grates are reversible to support
a round-bottom wok
Advance planning for 30" dual-fuel Professional range
All Professional ranges offer a number of choices in size and cooktop configurations.
The ranges are factory set for natural gas or liquid propane. Be sure to order the correct model for the installation situation. If the wrong fuel type is ordered, the range may be converted. Conversion orifices are packed with each product.
WB28K10553 high-altitude kit is available for operation above 6,000 feet. This kit includes orifices for both LP and natural gas operation.
All conversion kits must be installed by a qualified service technician at an additional cost.
12
Locate gas and electrical as shown.
Electrical requirements
Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 30-amp circuit for 30" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range.
Gas supply
• Natural gas models are designed to operate at 5" water column
pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
• The liquid propane models are designed to operate at 10" water
column pressure. For proper operation, the pressure of the LP source to the regulator must be between 11" and 13" water column.
Advance planning for 30" all-gas Professional ranges
28-7/8”
All Professional ranges are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation.
Conversion kits are included with the range if the wrong gas type was ordered. WB28K10553 high-altitude kit for operation above 6,000 feet is also available. The kits must be installed by a qualified service technician at additional cost.
Locate gas and electrical as shown.
Electrical requirements
Ranges must be connected to a 120V, 60Hz properly grounded dedicated circuit protected by a 15-amp circuit breaker or time-delay fuse.
Gas supply
• The natural gas models are designed to operate at 5" water
column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
• The LP models are designed to operate at 10" water column
pressure. For proper operation, the pressure of the LP gas supplied to the regulator must be between 11" and 13" water column.
Backsplash accessories
The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non­combustible backsplash can be used.
Order ZX12B30PSS, 12" backsplash Order ZXADJB30PSS, 30"-36" adjustable-height backsplash with warming shelf
Side view with a backsplash
to Front
Control Panel
28-1/4” to
Beveled
Edge of Control
Panel Bullnose
27-1/2” to
Beveled Edge
- Maximum Adjacent
Cabinet Depth
Flush
Installation
28-1/4”
to Front of
Door
Edge
3-3/16”
Depth
for
to Front of
31-1/16”
Handle
48-1/4”
with Oven Door
Open
7” Control
Panel Height
Optional Backsplash Accessories
30-36”
35-1/4”
to
36-3/4”
10-1/2”
13/16”
12”
1-1/2”
Product dimensions and clearances
Additional clearances
Installations without a hood require 48" minimum to combustibles. A custom hood installation with exposed horizontal combustible
The serial and model numbers are located behind the far left knob for convenience. The full rating label is located on the bottom of the control panel—visible when the oven door is open.
surfaces must have an “auto-on” feature. See hood installation instructions for specific hood clearances.
The surface of the entire back wall above the range and below the hood must be covered with a non-combustible material such as metal, ceramic tile, brick or stone.
14