ZDWI240WII – GE Monogram® Wine Reserve
14" Minimum
110˚
Wall
24"
Cabinet
34-1/2"-35"
24" Min.
23-3/4"
23-3/4" Min.
25-1/2"
Including
Handle
34-1/4"34-3/4"
23-3/4" Stainless steel
models
24-1/8" Framed models
1-1/2"
Locate Outlet
9"
Max.
10-1/2"
Dimensions and Specifications (in inches)
Installation Space
Product Clearances
All models are factory set for a 110° door swing.
For a minimum 90° door swing:
• Allow 4" min. clearance to wall on the hinge side.
For a full 110° door swing:
• Allow 14" min. clearance to wall on the hinge side.
The cutout depth must be 24"
The cutout dimensions shown allow for a full door swing and access
to the pull-out racks when installed as a built-in.
• The wine reserve can be free-standing.
Note: If installing between frameless cabinets, a 1/2" wide filler strip
or side panel may be required. The filler strip will act as a spacer
between the door case and adjacent cabinet and will prevent
interference with cabinet door swing. The width of the opening
must include filler panels.
• Wine reserve is vented at the front toekick to allow built-in
• Door swing is reversible.
Additional Specifications:
• A 120 volt 60Hz., 15 or 20 amp power supply is required. An
undercounter installation.
individual property grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall as shown. Electrical
must be located on rear wall as shown. Note: GFI (ground fault
interrupter) is not recommended.
Specification Created 10/07
120037
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call GE Answer Center®
service, 800.626.2000.
34-1/2" - 35"
24" Min.
47-1/2" Min.
1-1/2"
Locate Outlets
9"
Max.
10-1/2"
1-1/2"
9"
Max.
10-1/2"
24"
ZDWI240WII – GE Monogram® Wine Reserve
Dimensions and Specifications (in inches)
For a complete food storage center, install two Monogram refrigeration
modules side-by-side.
Note: Reversible door swing on wine chillers/reserves and beverage
centers only. See below for combination cutout dimensions.
Important Note: Products must operate from separate, properly
grounded receptacles.
Note: Additional cutout width may be required for models with
custom panels.
Grounding the Wine Reserve
IMPORTANT – (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong (grounding)
wall receptacle to minimize the possibility of electric shock hazard
from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to
make sure the outlet is properly grounded.
When a standard 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced with a
properly grounded 3-prong wall out.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO CONNECT THE
REFRIGERATOR TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
Specification Created 10/07
120037
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call GE Answer Center®
service, 800.626.2000.