GE ZDP484NGPSS, ZDP484LGPSS User Manual

ZDP484NGPSS (Natural Gas) ZDP484LGPSS (Liquid Propane)
GE Monogram® 48" Dual-Fuel Professional Range with 6 Burners, Grill and Griddle
Dimensions and Installation Information (in inches)
Professional ranges offer a number of choices in size and cooktop configurations.
All Professional Ranges are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation.
Note: Conversion kits are included with the range if the wrong gas type was ordered. High Altitude kit, WB28K10553 for operation above 3,000 feet (for Natural and LP gas models), is also available. The kits must be installed by a qualified service technician at additional cost.
Installation Information
Before installing, consult installation instructions packed with product or online at Monogram.com for current dimensional data.
A 48" or 54" wide professional vent hood with a minimum 1200 CFM is recommended for installation over this range.
Advance Planning
Refer to dimensional drawings for appropriate placement and necessary clearances when planning the installation.
• Working areas adjacent to the
range should have 18" minimum clearance between countertop and cabinet bottom.
• Clearance between range and side
wall or combustible material must be at least 12" on each side.
• Installation must conform with local codes. In the absence of local
codes, the range must comply with
the National Fuel Gas Code, ANSI
Z223.1-1990.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Listed by Underwriters Laboratories
Specification Created 7/08
130557
ZDP484NGPSS (Natural Gas) ZDP484LGPSS (Liquid Propane)
GE Monogram® 48" Dual-Fuel Professional Range with 6 Burners, Grill and Griddle
Dimensions and Installation Information (in inches)
Electrical Requirements
Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit
protected by a circuit breaker or time-delay fuse. Install a 50-
amp circuit for 48" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range.
Universal Utility Locations
Locate gas and electric as shown
Gas Supply
• The natural gas models are designed to
operate at 5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
• The LP models are designed to operate
at 10" water column pressure. For proper operation, the pressure of the LP gas supplied to the regulator must be between 11" and 13" water column.
Optional Backsplash Accessories
The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non­combustible backsplash can be used.
Order one with a 48"-wide range backsplash ZX12B48PSS–12" backsplash ZXADJB48PSS– 30"-36" adjustable-height backsplash with
warming shelf
Side View with a Backsplash
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Listed by Underwriters Laboratories
Specification Created 7/08
130557