GE ZDP36L4DWSS User Manual

™
21-1/4"
12"
1-1/2"
35-1/4"-36-3/4"
28-1/4"
35-7/8"
Available Backguards
Monogram.
ZDP36L4DWSS—36" Professional Ranges
Dimensions and Specifications (in inches)
ZX22B36WSS
ZX12B36WSS
These ranges are factory set for either natural gas or liquid propane gas.
36" Natural Gas Model:
ZDP36N4DWSS–4 gas burners and griddle
36" Liquid Propane Gas Model:
ZDP36L4DWSS–4 gas burners and griddle
Accessory Requirements:
All models require the installation of a backguard. A backguard should be ordered at the same time as the range. Both must be on site at the time of installation.
Order one backguard for 36" models:
ZX1B36WSS–1-1/2" high backguard (required for island installations) ZX12B36WSS–12" high backguard ZX22B36WSS–22" high backguard with warming rack (2 piece)
ZX1B36WSS
Revised 7/97
Advance Planning:
Refer to dimensional drawings for appropriate placement and necessary clearances when planning the installation.
• Cabinetry cannot be installed directly above the range.
• This range requires the installation of a vent hood, 30" to 36" above the surface. – The vent hood must be at least 24" deep. – The vent hood must be the same width as the range. – The vent hood must provide at least 600 CFM and
up to 800 CFM.
– When installing a range that includes a grill, select a
blower on the high end of the CFM recommendation.
• Working areas adjacent to the range should have 18" minimum clearance between countertop and cabinet bottom.
• Clearance between range and side wall or combustible material must be at least 12" on each side.
For answers to your GE Monogram,™GE Profile, GE, Hotpoint and RCA appliance questions, call GE Answer Center®service, 800.626.2000.
L
Listed by Underwriters Laboratories
U
R
™
Monogram.
ZDP36L4DWSS—36" Professional Ranges
Dimensions and Specifications (in inches)
36" Wide Range Hood
4"
13"
18" Min.
12"
12"
4"
Cooking Surface
Max. 12" Min. to
Combustible Material Each Side
36" Min. to Combustible Material From Cooking Surface
If the range is installed in an island:
• Allow 12" min. clearance at the back to combustible
materials.
• Allow 36" min. above the cooking surface to combustible materials.
• The vent hood must provide at least 600 CFM and up to 1200 CFM.
• Installation must conform with local codes. In the absence of local codes, the range must comply with the National Fuel Gas Code, ANSI Z223.1-1990.
A.G.A. approved
3/-1/4"
Gas Supply
35-3/8" Max. for Counter Level 36-3/4" Max. with Range Leveling Legs Fully Extended
29-1/16"
12"
12"
High Shelf
Low Back
0" Clearance
3-1/4"
21-1/4"
3/-1/2"
Electrical Supply
36" Min. 
to Combustibles
1-1/2"
12" Min. to Combustibles Without Backguard
to Combustibles
Island Trim
0" Clearance
Installation Information:
Before installing, consult installation instructions (Pub. #49-8786) packed with product for current dimensional data.
36" Min. 
Revised 7/97
28-1/4"
31-1/2"
45-5/8"
For answers to your GE Monogram,™GE Profile, GE, Hotpoint and RCA appliance questions, call GE Answer Center®service, 800.626.2000.
L
Listed by Underwriters Laboratories
U
R
Loading...
+ 1 hidden pages