™
21-1/4"
12"
1-1/2"
35-1/4"-36-3/4"
28-1/4"
35-7/8"
Available Backguards
Monogram.
ZDP36L4DWSS—36" Professional Ranges
Dimensions and Specifications (in inches)
ZX22B36WSS
ZX12B36WSS
These ranges are factory set for either natural gas or
liquid propane gas.
36" Natural Gas Model:
ZDP36N4DWSS–4 gas burners and griddle
36" Liquid Propane Gas Model:
ZDP36L4DWSS–4 gas burners and griddle
Accessory Requirements:
All models require the installation of a backguard. A
backguard should be ordered at the same time as the
range. Both must be on site at the time of installation.
Order one backguard for 36" models:
ZX1B36WSS–1-1/2" high backguard
(required for island installations)
ZX12B36WSS–12" high backguard
ZX22B36WSS–22" high backguard with warming rack
(2 piece)
ZX1B36WSS
Revised 7/97
Advance Planning:
Refer to dimensional drawings for appropriate placement
and necessary clearances when planning
the installation.
• Cabinetry cannot be installed directly above the range.
• This range requires the installation of a vent hood,
30" to 36" above the surface.
– The vent hood must be at least 24" deep.
– The vent hood must be the same width as the range.
– The vent hood must provide at least 600 CFM and
up to 800 CFM.
– When installing a range that includes a grill, select a
blower on the high end of the CFM recommendation.
• Working areas adjacent to the range should have
18" minimum clearance between countertop and
cabinet bottom.
• Clearance between range and side wall or combustible
material must be at least 12" on each side.
For answers to your GE Monogram,™GE Profile,
GE, Hotpoint and RCA appliance questions, call
GE Answer Center®service, 800.626.2000.
L
Listed by
Underwriters
Laboratories
U
R
™
™
Monogram.
ZDP36L4DWSS—36" Professional Ranges
Dimensions and Specifications (in inches)
36" Wide Range Hood
4"
13"
18" Min.
12"
12"
4"
Cooking Surface
Max.
12" Min. to
Combustible
Material
Each Side
36" Min. to
Combustible
Material From
Cooking Surface
If the range is installed in an island:
• Allow 12" min. clearance at the back to combustible
materials.
• Allow 36" min. above the cooking surface to
combustible materials.
• The vent hood must provide at least 600 CFM and
up to 1200 CFM.
• Installation must conform with local codes. In the
absence of local codes, the range must comply with
the National Fuel Gas Code, ANSI Z223.1-1990.
A.G.A. approved
3/-1/4"
Gas Supply
35-3/8" Max. for Counter Level
36-3/4" Max. with Range Leveling Legs Fully Extended
29-1/16"
12"
12"
High
Shelf
Low Back
0" Clearance
3-1/4"
21-1/4"
3/-1/2"
Electrical Supply
36" Min.
to Combustibles
1-1/2"
12" Min. to Combustibles
Without Backguard
to Combustibles
Island Trim
0" Clearance
Installation Information:
Before installing, consult installation instructions
(Pub. #49-8786) packed with product for current
dimensional data.
36" Min.
Revised 7/97
28-1/4"
31-1/2"
45-5/8"
For answers to your GE Monogram,™GE Profile,
GE, Hotpoint and RCA appliance questions, call
GE Answer Center®service, 800.626.2000.
L
Listed by
Underwriters
Laboratories
U
R
™