GE ZDI15CHBB, ZDI15CHWW, ZDI15CJBB, ZDI15CJWW, ZDI15CKBB Installation Guide

...
Installation Instructions
Automatic Icemaker
ZDI15 ZDIS15
Design Guide with Installation Instructions
Monogram:_
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions for
local inspector's use.
IMPORTANT- Observe all governing codes
and ordinances.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions
with your Owner's Manual for future reference.
WARNING:
This appliance must be properly grounded. See "Power Supply", page 4.
AVERTISSEMENT :
Get appareil doit _tre correctement mis
la terre. Consulter _{Alimentation
_lectrique _, page 4.
CONTENTS
Design Information
Models Available ..............................................................3
Cutout & Product Dimensions ........................................3
Optional Accessories ......................................................3
Tools and Materials Required ......................................3
Installation
Advance Planning ............................................................4
Power Supply ....................................................................4
Remove Packaging ..........................................................5
Adjust Height of Ice Machine ........................................5
Water Supply ....................................................................6
Connect the Drain ............................................................6
Connect Water Supply ....................................................7
Reverse Door Swing ....................................................7, 8
Accessories
ZIP75WW, ZIP75BB Kit for 3/4" thick panels ........9, 10
If you received a damaged ice machine, you should
immediately contact your dealer or builder.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not
covered under the GEAppliance Warranty. See the Owner's Manual for warranty information.
Use this appliance only for its intended purpose. Check with local utilities for electrical codes that apply
in your area. Local codes vary. Installation, electrical connections and grounding must comply with
applicable codes. In the absence of local codes, the ice machine should be installed in accordance with
National Electrical Code ANSl/NFPA 70-1990 or latest edition.
For Monogram local service inyour area, call
1.800.444.1845. For Monogram Service in Canada, call
1.888.880.3030. For Monogram Parts and Accessories, call
1.800.626.2002.
MODELS AVAILABLE
Design Information
ZDI15, ZDIS15 Available in black, white and stainless steel.
CUTOUT & PRODUCT DIMENSIONS
34" min.
Adjustable
to 34-1/2"
23-5/16" to
14-13/16'
The ice machine may be installed below a countertop or used free-standing.
Cutout dimensions shown allow for a full door swing.
When installing a 3/4"thick custom door panel,
additional clearances atthe sides may be required. Frameless Cabinets:
If installing between frameless cabinets, a 1/2" filler strip or side panel may be required on the hinge side. The filler strip will act as a spacer between the door
case and adjacent cabinet, and will prevent interference with icemaker door swing. The width of
the opening must include filler or side panel thickness.
NOTE: The addition of a 3/4" thick front panel will result in a front to back depth of 24-1/16."
OPTIONAL ACCESSORIES
ZIP75WW White and ZIP75BB Black--For the installation of atrimless 3/4" thick custom panel on
white and black models (not for stainless steel models). A custom handle of your choice may be installed onto the 3/4" panel. See installation instructions on pages 9 and 10.
TOOLS AND MATERIALS REQUIRED
1/4" socket
3/4" adjustable wrench
•Level
GE SmartConnectTM Refrigerator Tubing Kit or 1/4" O.D. copper tubing, of sufficient length to reach the installation
ZPK1--Drain Pump Kit. For use when a floor drain is not available.
3
ADVANCE PLANNING
weight, TWO PEOPLEARE REQUIRED TO
CAUTION: Duetoexcessive
MOVE AND INSTALL THIS ICE MACHINE.
MISE EN GARDE :
A cause de son poids elev&lL FAUT DEUX PERSONNES POUR DEPLACER ET
INSTALLERCEDISTRIBUTEUR DE GLACE.
Choose the location:
The ice machine must be installed in an area protected from elements such as wind, rain, water
spray or drip. The area should be ventilated with temperatures above 55°F (13°C) and below 110°F (43°C). Best results are obtained between 70°F (21°C) and 90°F (32°C).
The ice machine may be closed in on the top and three sides as long as the front is unobstructed for air circulation and proper operation.
-Installation should be such thatthe ice machine can be moved forward for servicing, if necessary.
-The bottom grille on the front must be unobstructed
to provide proper air flow.
Before you begin:
1. If a custom panel is to be installed, follow the
instructions shown on pages 9 and 10.
-Order ZIP75 (black or white) panel kit.
-Order the custom panel from the cabinet manufacturer.
-Secure the custom panel onto the ice machine.
2. Determine a method of drainage. If a floor drain is to be installed, the drain must be accurately
located. The installation of a custom door panel will
affect the drain location. See page 6 to determine the exact location of the floor drain, front to back, with or without a custom door panel.
-A drain pump kit, ZPK1, is available and will not
interfere with placement of the ice machine.
3. The door swing is reversible. If desired, change the door swing before installation.
4. Slide the ice machine into the installation location.
-Open and close the door to be sure there is no interference.
-Check to be sure the ice machine can be moved back into the opening, flush with adjacent
cabinetry. There should be no interference with
the floor drain.
POWER SUPPLY
IMPORTANT: (Please read carefully).
FORPERSONAL SAFETY,THIS APPLIANCE MUST BE
PROPERLYGROUNDED.
Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Code or prevailing local codes and ordinances.
This ice machine must be supplied with 115V,60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
Electrical Supply Should Enter From Back Wall
InShaded Area.
A properly grounded 3-prong receptacle should be located within reach of the ice machine's 66" long power cord. For a built-in installation, locate the receptacle in the shaded area shown.
IMPORTANT: (Please read carefully).
The power cord of this appliance is equipped with a three-prong (grounding) plug that mates with a standard three-prong grounding wall receptacle to minimize the possibility of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and has the correct polarity.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.
Do not,under any circumstances, cut or remove the third (ground) prong from the power cord.
DO NOT USEAN EXTENSION CORD.
4
REMOVE PACKAGING AND PARTS
Laythe carton on rear face and break open the bottom flap.
Setthe carton upright with all four bottom flaps
outward.
Lift carton up and off icemaker.
Remove all tape and packaging material from the outside and inside
of the cabinet,
Locate parts package with plastic plug buttons. Set aside.
Open Bottom Flaps
ADJUST HEIGHT OF ICE MACHINE
Height adjustments may be necessary to install the ice machine below a countertop, and may be accomplished by adjusting both the front and rear leveling legs,
ower
To adjust the height:
With one person holding the ice machine, carefully
tilt the machine to access the leveling legs,
Use an adjustable wrench to turn the legs.
-Turn legs right to lower, turn left to raise the machine,
Check top and side with a spirit level. Continue adjusting legs until the ice machine is level
and stable.
WATER SUPPLY
A cold water supply is required for icemaker operation. The water pressure must be between 20 and 120 p,s.i.
Water Supply Should
Enter From Back Wall In Shaded Area.
Route GE SmartConnect TM Kit or 1/4" O.D. copper tubing between house cold water line and the water
connection location.
The water line should be long enough to extend to the back of the ice machine. Allow enough to accommodate moving unit forward for service.
NOTE:The only GEapproved plastic tubing is supplied in the GE SmartConnectTM Refrigerator Tubing kits. Do not use any other plastic water supply line because the line is under pressure at all times. Other types of plastic may crack or rupture with age and cause water damage to your home. GE SmartConnecf MRefrigerator Tubing Kits are available in the following lengths:
2'(0,6 m) WX08X10002 6'(1.8 m) WX08X10006
15' (4,6m) WX08X10015
25' (7.6 m) WX08X10025 Shut off the main water supply
Turn on the nearest faucet long enough to clear the line of water.
Install a shut-off valve between the ice machine
water valve and cold water pipe in a basement or cabinet, The installation of an easily accessible shut-off valve in the water line is required,
NOTE: Itis best to install the valve into a vertical water pipe. If you install the valve into a horizontal
water pipe, make the connection atthe top or side, rather than atthe bottom, to avoid drawing off any sediment from the water pipe,
Turn on the main water supply and flush debris from the line. Run about a quart of water through the tubing into a bucket, Shut off water supply at
the shut-off valve.
WATER SUPPLY (cont.)
NOTE: Saddle type shut-off valves are included in many water supply kits, but are not recommended for this application,
NOTE:Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts. Consultwith your licensed plumber.
Install optional water filter in the water line near the ice machine. A water filter is recommended in areas
where water supply contains sand or particles.
Installation instructions are packed with the filter.
CONNECT THE DRAIN
This ice machine is equipped with a gravity
drain to prevent water from flowing back into the ice machine storage bin and potentially flowing onto the floor.
A floor drain is acceptable, The ideal
installation has a standpipe with a 2" to
1-1/2" PVCdrain reducer
installed directly below the outlet of the drain tube:
-7-1/2" to centerline _
of the opening,
3-1/2" high.
-Approximately _j
-22" from the front,
or 22-3/4"when _5,, _ 7-t/2"-_:L_
installing a 3/4" LocateStalldpipein exact
door panel,
Drain lines must be at least 5/8" inside diameter.
NOTE:A drain pump is necessary when a floor drain is not available, Order ZPK1 Drain Pump Kit or contact your local plumber for a recommended pump available in your area.
TEST DRAIN HOSE ALIGNMENT: Before sliding the ice machine into the cabinet opening, check to be sure
the bottom of the drain tube is below the rear cover. Totest, place a pan belowthe drain hose. Pour a
gallon of water into the ice bin and checkto be sure that water does not wet the rear cover.
Custom Panel
3q/2"
Centerof TheCutout
/Drain Hose
CONNECT WATER SUPPLY
The water line should be flushed to clear any foreign material before connecting to the icemaker.
Connect the water line to the water supply tube outside of the rear access cover.
Water
Supply
Line
CopperTubing:
Use a standard plumbing female connector or union for 1/4" copper tubing that can be purchased locally.
Coupling
(NotSupplied)
Nut
(Supplied)
\
Ferrule
Lineto
Icemaker
GE SmartConnectTM Tubing:
Insert the molded end ofthe tubing into the icemaker connection. _ghten the compression nut until it is just hand tight.
Tighten one additional turn with a wrench, Overtightening can cause leaks!
Make sure there are no sharp bends or kinks that could restrict water flow.
Slide the ice machine into its permanent location.
To prevent rattling, be sure the copper tubing
does not touch the side wall or
other parts inside the cabinet.
Open the shut-off valve. Check for
leaks. -lighten any connections (including
connections atthe valve)
if necessary.
(NotSupplied)
Water Pan
Water Valve -
5-11/16" 4-5/8"
\
Nut
(Supplied)
REVERSE THE DOOR SWING
IMPORTANT: Disconnect power to
the ice machine. Tools Required:
1/4" and 5/16"wrench
Flat putty knife
Phillips screwdriver
Parts Supplied:
4 plug buttons
4 hinge screws (on some models)
Parts Identification: (For Reference 0nly)
Hinge Pin Handle Screw
5/16" Hex Head Endcap Screw
Hinge Screw
Remove the handle screws and lift off handle. (On black and white models only.)
Remove the hinge pin from the top hinge.
Lift the door off of the bottom hinge. Place the hinge pin back into the top hinge.
Reverse the door endcaps:
Remove the screws and endcaps from the door, top and bottom.
Place the top endcap onto the bottom of the opposite side of the door with the longflat side facing the
door front.
Place the bottom endcap onto the top of the opposite side of the door, with the longflat side facing the
door front.
Setthe door aside.
REVERSE THE DOOR SWING (cont.)
Reverse the hinges:
Using a flat putty knife, remove the screw hole plugs opposite the door hinges, top and bottom. Set aside.
Remove the two screws holding top hinge.
Turn the hinge upside down, with the hinge pin pointing up. Reinstall the hinge on the opposite side
at the bottom of the door.
Remove the bottom hinge. Turn the hinge upside down and install on the opposite side atthe top.
Push screw hole plug buttons (supplied) into the original screw holes.
Remove the top hinge pin.
Place plastic hinge sleeve on the bottom hinge and position the door onto the pin.
Place plastic hinge sleeve in the top hinge hole on the door. Align the door on the bottom hinge and replace top hinge pin.
Reinstall handle with original screws.
Top Hinge _ HingePin
HingeSleeve/ DoorStop
T
REVERSE THE DOOR SWING (cont.)
To reverse the door catch:
Remove the plastic screws from the opposite side
of the door.
Remove the metal screws from the magnetic door
catch and reinstall on the opposite side of the door.
Install the plastic screw into place on the opposite
side of the door.
Reverse Door Catch Position
BottomHinge
Hex Head Hinge Screw
, Hex Head
Hinge Screw
Sleeve/
_'-- Hinge Pin
Top
BottomHinge
8
Installation Instructions for ZIP75WW, ZIP75BB Kit
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions for
local inspector's use.
IMPORTANT- Observe all governing codes
and ordinances.
Note to Installer- Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions with
your Owner's Manual for future reference.
WARNING:
To prevent electric shock, disconnect electrical power supply to ice machine
before installing front panel. Do not operate ice machine while installing panel.
AVERTISSEMENT :
Pour _viter les chocs _lectriques, il faut
debrancher I'alimentation du distibuteur de glace avant d'installer le panneau avant.
Le distributeur de glace ne dolt pas _tre en marche pendant I'installation du panneau avant.
Kit Contents:
2 side trim pieces
8 side trim screws
Door handle
This kit contains a new handle and 2side mounting brackets to support a trimless custom door panel up to 3/4"thick. A custom handle may replace the supplied handle.
IMPORTANT:
Cut edges of the custom door panel will be seen and must be finished for best appearance. The back side of the panel should be finished a minimum of 1/2"
on all sides.
The custom panel, both raised and flat design, should be constructed in the same manner as typical
cabinet doors.
Order the custom panel from the cabinet manufacturer.
Be sure to provide the exact dimensions so that the
panel is constructed accurately.
Left Trim
29-1/2" I
Custom
Panel
Right Trim
Tools and Materials Required:
8 flat head wood screws, 1/2" long
Drill and 1/8" bit
Safety glasses
Tape
Custom panel NOTE: If installing a 3/4" trimless custom panel, a
3/4"wide filler strip or side panel may be required. The filler strip will act as a spacer between the icemaker case and the adjacent cabinet, and will prevent interference with the icemaker door swing. The width of the cutout opening must include the additional width of the filler panels.
14_23/32"
Installation Instructions for ZIP75WW, ZIP75BB Kit
I STEP 1 DISCONNECT POWER I
STEP 2 REMOVE HANDLE
Remove the door handle by removing the two top mounting screws. Set screws aside, Discard handle.
The Monogram nameplate is held in place with adhesive. Remove the nameplate.
STEP 3 MARK MOUNTING
Align and hold the side trim pieces againstthe ice machine door and mark screw locations on the sides.
Drill 1/8" pilot holes into the door sides of the ice machine.
STEP 4 SECURE CUSTOM HANDLE
A custom handle can be installed onto the 3/4"thick
panel, replacing the supplied handle.
The custom handle can be installed atthe top or side of the panel.
Drill pilot holes through the front of the custom panel
to match the chosen handle.
TO THE ICE MACHINE
AND NAMEPLATE
SCREW LOCATIONS
TO CUSTOM PANEL.
(SKIP THIS STEP IF
YOU ARE USING THE SUPPLIED HANDLE)
STEP 5 SECURE SIDE TRIM PIECES
TO CUSTOM PANEL
Lay the custom panel appearance-side-down on a clean surface.
Align top and bottom side trim to the custom panel sides.
Tape the side trim pieces to the back of the custom panel,
Place the panel with trim against the door to be sure
that trim and panel fits the door side to side and top to bottom. Adjust as needed.
Mark screw locations and remove trim. Drill pilot holes.
Install side trim to the back side of the custom panel with screws (not supplied). Use flat head
wood screws approximately 1/2" long,
STEP 6 INSTALL ASSEMBLED PANEL
ONTO THE ICE MACHINE
Install panel to ice machine with supplied screws,
4 on each side.
STEP 7 INSTALL SUPPLIED DOOR
HANDLE (IF USED)
Install the new supplied handle with original screws.
Secure the handle to the panel with flat head wood screws.
Replace original handle screws in the top of the door
frame,
10
Notes
11
NOTE:While performing installations described in this book,
safety glasses or goggles should be worn.
For Monog'ram local service i)_ )our (m_a, c(dl
1.600.4dd. l,_4).
NOTE: t ro(lucl improv(_m(_m is a comimfillg (md(_avor al G( neral El(_ctri(. Th(r(for(_, malerials, appearan(:(
and sp(_(ifi(alions ar(_ sul_je(:t to (h_mg¢ wilholll noli((.
o 6)
Pub.No.49-60016-3 ] PartNo.197D2522PO01
2217279Rev.1 02-04JR
Printedinthe UnitedStates
Monogram;
J
GEConsumer & Industrial
Louisville, KY40225
@2004GE Company
Loading...