GE WSKS3040E User Manual

WSKS3040E – GE Spacemaker
®
2.1 Cu. Ft. Stationary Washer with Stainless Steel Basket
360440
Washer Note:
Washer wall outlet must be located within 36" of
service cord entry. Wall outlet must not be located behind dryer.
R
Listed by
Underwriters
Laboratories
,
®
GE Profile
or
®
appliance questions, visit our website at
ge
®
service,
800.626.2000.
WSKS3040E – GE Spacemaker
®
2.1 Cu. Ft. Stationary Washer with Stainless Steel Basket
360440
This kit consists of the following:
2 Bottom Brackets
6-1/4 x 3 inch wood screws
7-1/4 x 1-1/2 inch wood screws
Dryer Requirements
dryer
installation instructions for exhausting
These instructions explain two mounting positions for your 24 inch dryer.
Installation Procedure:
1
Obtain two pieces of 2x4 long enough to span at least two wall studs and the width of the dryer.
2. Locate wall stud center lines. Mark wall stud center lines on two pieces of 2x4 in relationship to position
dryer is to be mounted.
3.
Referring to dimensional drawing, draw a horizontal reference line (73") from the floor to locate upper
2x4 support.
4. Position, level and secure upper 2x4 with four 1/4 x 3 inch wood screws. The bottom of the 2x4 should
be positioned on reference line.
5.
dimensional drawing
, draw a horizontal reference line 32" down from the bottom of the upper
2x4 support.
6.
Position, level and secure lower 2x4 with two 1/4 x 3 inch wood screws. The center line of the 2x4 should
be positioned
on reference line.
7. Referring to figure 1, mount the metal wall bracket 1/8 inch from the bottom of the upper 2x4 support with
five 1-1/2 inch wood screws.
8.
secure
9.
drawing
For other optional exhaust directions as shown in
dimensional drawing
(rear and sides)
refer to
dryer installation instruction sheet.
10. Position the dryer on the wall mounting bracket and check that the dryer is plumbed.
11. If the dryer needs plumbing, use some of the twelve washers supplied with the kit as spacers behind
brackets of figure 2 and secure the dryer to the lower 2x4 support using the remaining 1-1/2 inch
wood
screws
General Information :
The back of the dryer is not accessible for service or maintenance after dryer mounting
access, the dryer must be removed from the wall.
CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE INSTALLING OR
SERVICING DRYER.
The electrical outlet must be located above the dryer, or beside the dryer if adequate
dryer-to-wall clearance
dryer or a 120 volt dryer from the service cord
entry on the rear of the dryer.
CAUTION
The 120 volt receptacle on the back of the
240 volt dryer must not be used with this
wall mount kit.
WALL BRAC KET
REAR V IEW FRONT V IEW
2 x 4
figure 1
figure 2
1
/8" MAX
WMK-35 Wall Kit Installation
20" Max. Opening
120V 20A or 208-240V 30A
3-3/4
3
3
Rear Exhaust
5-1/8
8
74-1/8
78
74-1/8
Service Cord Entry at Bank of Appliances
R.H EXH
5-1/8
4" Dia. Exhaus
t
3-1/8
Both Sides
33-1/
4
38
79-1/4
32
2 x
4
2 x
4
6
24-1/
2
DSKS433 DSKS333
WSLP1100 WSLS110
0
WSKS3040 Standpipe 33" Minimum
If Less Than 33" Use Syphon Break Kit WH49X228
26
28
23-7/
8
6
120V
15 or 20A
1-1/2
23-5/8
Standpipe
& Faucets
33" Min.
portbl_or_statnry_bifl_wshr.eps
46
Loading...
+ 1 hidden pages