WattStation should be installed only a licensed contractor, and/or a licensed electrician in accordance with all applicable state, local and national electrical codes and standards. WattStation should be inspected by a qualified inspector prior to initial use. Under no circumstances will compliance with the information in this manual relieve the user of his/her responsibility to comply with all applicable codes or safety standards.
Page 3
Page 4
COMPONENT
TORQUE VALUE
TOLERANCE
M5 x 0.8 screw
30 in-lb
+/- 2 in-lb #12 thread-cutting screw
30 in-lb
+/- 2 in-lb 10-32 UNF screw
35 in-lb
+/- 5 in-lb 6-32 UNC screw
12 in-lb
+/- 2 in-lb Fuse block lugs
45 in-lb
+/- 2 in-lb Field wiring lugs
50 in-lb
+/- 2 in-lb Din-rail mounted terminal block lugs
12 in-lb
+/- 2 in-lb Contactor lugs
50 in-lb
+/- 2 in-lb Ground bar lugs
35 in-lb
+/- 2 in-lb M3 x 0.5 screw
12 in-lb
+/- 2 in-lb #8 thread cutting screw
30 in-ib
+/- 2 in-lb 3/4" cable strain relief fitting
Hand-Tight + 1/4 turn
N/A
WARNING: Danger of electrical shock or injury. Turn OFF power at the panelboard or load center before working inside the equipment or removing any component. Do not remove circuit protective devices or any other component until the power is turned OFF.
WattStation should be installed only by a licensed contractor, and/or a licensed electrician in accordance with all applicable state, local and national electrical codes and standards.
Page 5
Page 6
Page 7
WARNING: Danger of electrical shock or injury. Turn OFF power at the panelboard or load center before working inside the equipment or removing any component. Do not remove circuit protective devices or any other component until the power is turned OFF.
WattStation should be installed only by a licensed contractor, and/or a licensed electrician in accordance with all applicable state, local and national electrical codes and standards.
Page 8
Page 9
Page 10
Page 11
SAE Compliant
Level II per J1772 Vehicle Interface
SAE J1772 EV connector Cable Length
16’ cable AC Max Charging Power Output**
7.2 kW (240VAC @ 30A) Voltage and Current Rating
208-240VAC @ 30A AC Power Input
208-240VAC requiring only Line 1, Line 2 and Earth ground Recommended Service Panel Breaker
2-pole 40A breaker on dedicated circuit
Ground Fault Protection
Internal 20mA CCID with auto-re-closure, does not require a GFCI in service panel Ground Monitoring
Ensures ground is present between vehicle and WattStation, and between WattStation and load center Standby Power
0 W when not charging and turned off by pushbutton switch Outdoor Rated
NEMA 3R Safety Compliance
ETL and CETL listed conforming to UL 2594, 2231 and 1998 Surge Protection
6kV @ 3000A EMI Compliance
FCC Part 15 Class A Operating Temperature
-30°C to +50°C ambient Operating Humidity
Up to 95% non-condensing Unit Weight
35 lbs Dimensions
24” H x 16” W x 6” D