GE UCG1600LBB, UCG1600LWW, UCG1680LSS Installation Guide

Installation Instructions
If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737) or visit our website at: GEAppliances.com. In Canada, please call 1.800.561.3344 or visit www.geappliances.ca
15” Built-In Compactors
UCG1650LII - Universal II - Also, refer to the instructions provided on the included template. UCG1680LSS - Universal SS UCG1600LWW - Universal WW UCG1600LBB - Universal BB
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire, explosion, electric shock, and to prevent property damage, personal injury, or death.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation to avoid severe or fatal shock injury.
WARNING
Do not allow items to fall or collect behind the compactor. Failure to follow this instruction could result in a fire.
KEEP THESE INSTRUCTIONS
FOR YOUR SAFETY
Read and observe all WARNINGS and CAUTIONS shown throughout these instructions.
While performing installations described in this booklet, gloves, safety glasses or goggles should be worn.
IMPORTANT – Observe all governing codes and
ordinances.
Note to Installer – Be sure to leave these instructions for the consumer’s and local inspector’s use.
Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.
Skill Level – Installation of this appliance requires basic mechanical and electrical skills.
Completion Time – 1 to 3 Hours. New installations require more time than replacement installations.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under the GE Appliances Warranty. See warranty information.
IMPORTANT
This compactor is for household use only.
Use this compactor only for its intended purpose.
This compactor is designed for BUILT-IN
installations ONLY.
Care should be exercised when the appliance is installed or removed, to reduce the likelihood of damage to the power supply cord.
If you received a damaged compactor, you should immediately contact your dealer or builder.
31-31581 03-17 GEA
Design Information
PRODUCT DIMENSIONS AND CLEARANCES
24”
(61 cm)
min.
15”
(38.1
cm) min.
34” (86.4 cm)
to
35” (88.9 cm)
33-3/4”
(85.7 cm)
min.
to
35”
(88.9 cm)
max.
 $OORZƎFP
clearance at the front for a full drawer opening.
 $OORZƎFP
clearance on the right side to the nearest vertical wall or cabinet for bag removal.
Note: This compactor is designed for built-in applications only.
Locate the outlet 18” (45.7 cm) min. from
the floor, 3” (7.6 cm) min. from either side
23” (58.4 cm)
TOOLS REQUIRED
• Level
• Phillips screwdriver
• Pliers
All parts are located in a package inside the drawer. To order additional parts, call 800.626.2002 or visit GEAppliances.com in the United States. In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca.
• Gloves
• Measuring tape
14-7/8” (37.8 cm)
PARTS SUPPLIED
• 6 mounting screws, #8 x 11/16” (1.8 cm) long
• 2 side-mounting clips
• 2 countertop retaining brackets
2
ADVANCE PLANNING
CLEARANCES
• You should be able to fully open the compactor drawer. Six inches (15.2 cm) is required on the right side of the compactor for bag removal.
• Allow 23 inches (58.4 cm) in front of the compactor to remove the drawer.
• This compactor is designed as a built-in appliance only. It may be located in any convenient space under a countertop. DO NOT OPERATE FREE-STANDING.
• The compactor may be installed beneath countertops of stone or other materials that will not accept screws. No trim kit is required.
The compactor must be securely installed in a cabinet that is firmly attached to the house structure. Weight on the compactor drawer could cause the compactor to tip and result in injury. Never allow anyone to climb, sit or hang on the compactor drawer.
MODEL WITH A CUSTOM DRAWER PANEL - UCG1650LII
The custom drawer panel and custom handle of your choice should be secured to the compactor before installation begins. A template with instructions and installation hardware is provided with this model.
For planning purposes, you may order the template in advance by calling GE Appliances at 1.800.GE.CARES (1.800.423.2737) or by visiting our website at GEAppliances.com in t he United States. In Canada, call 1.800.561.3344 or v i si t GEAppliances.ca.
Order Pub. No. 31-31582. Complete panel installation instructions are included on the template.
CUSTOM PANEL SIZE REQUIREMENTS:
Maximum panel weight is 12 LBS (5.4 kg).
´Ǝ (1.9 cm) Thick Custom Panel
´Ǝ
(74.5 cm)
´Ǝ (37.8 cm)
3
Installation Preparation
ELECTRICAL REQUIREMENTS
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation to avoid severe or fatal shock injury. Do not use an extension cord or adapter plug with this appliance.
• The power supply cord and plug should be brought to a separate 15- or 20-ampere branch circuit single grounded receptacle. The outlet box should be located within reach of the 36” (91.4 cm) power cord.
• This appliance must be supplied with 120V, 60Hz and connected to an individual properly grounded branch circuit, protected by a 15- or 20-ampere circuit breaker or time-delay fuse.
• If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
IMPORTANT: Observe all governing codes and ordinances.
- Electrical Shock Hazard
GROUNDING REQUIREMENTS (CONT.)
Grounding Instructions:
For your personal safety, this appliance must be grounded while in use to reduce the risk of electric shock. The appliance is equipped with a three­conductor power supply cord and a three-prong grounding-type plug to fit the proper grounding-type receptacle. The green (or green and yellow-colored) conductor in the cord is the grounding wire. Never connect the green (or green and yellow) wire to a live terminal.
This appliance is for use on a nominal 120-volt circuit and has a grounding attachment plug as shown in the figure below. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance.
3-prong grounding-type wall receptacle 3-prong
grounding plug
Grounded outlet
GROUNDING REQUIREMENTS
WARNING
The improper connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded.
• Electrical Ground is REQUIRED on this compactor.
• DO NOT ground to a gas pipe.
• DO NOT change the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in an electrical shock.
• DO NOT use an extension cord with this compactor.
Failure to follow these instructions could result in death or serious injury.
Power supply cord
To minimize possible shock hazard, the cord must be plugged into the proper mating three-prong grounding-type wall receptacle, grounded in accordance with the National Electrical Code ANSI/ NFPA70—latest edition* and all local codes and ordinances.
If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded three-prong wall receptacle installed by a qualified electrician.
Grounding plug
Copies of the standards listed may be obtained from: * National Fire Protection
Association Batterymarch Park, Quincy, MA 02260
4
Installation Preparation
UNPACKING THE COMPACTOR
1
Move the compactor close to the installation
location.
Use a section of the shipping carton to protect the finished floor.
Remove all protective packaging materials such as tape or shipping pads. Remove waxy residue caused by shipping material with a mild solution of liquid household cleaner and water.
Check that the power supply cord is attached to the cord clip on the rear of the compactor.
Cord clip
LEVELING THE COMPACTOR
2
The top of the compactor should be at least
ƎPPIURPWKHWRSRIWKHFDELQHWRSHQLQJ
You can adjust the height of the compactor by turning the screws on the front leveling legs and rear wheels.
Front leveling legs
Rear wheels
Place a level inside the compactor on the floor of the cabinet.
IMPORTANT: Use the shipping carton as a pad. Do not slide the compactor across a finished floor. Damage will occur.
Open the compactor drawer and remove any shipping materials or other items shipped in the drawer.
Do not remove the compactor bag (if installed).
Grasp the sides of the drawer and lift it out of
the compactor. Place the drawer on a protected surface. The drawer can scratch a finished floor.
Use the leveling legs to adjust level front to back and side to side.
5