GE TPX24SPBBS User Manual

Revised 2/99
TPX24SPBBS - GE Profile Performance™23.5 Cu. Ft. CustomStyle™Side-By-Side Refrigerator
Case Dimensions (in inches/cm.) Installation of Water and Electrical Outlets
I
G
Top View
40-3/8
35-3/4
45-5/8
Recommended water line location using recess in rear wall
Recommended single loop of 1/4" copper water line
Water hook-up on the refrigerator
18"
24"
Allow 48" minimum water line to enable refrigerator to be pulled forward.
C
F
D
E
Side View
28-7/16
26-3/8
23-7/8
69-3/4
Rear Wall View
A
1''
(2.54 cm.)
B
Front View
69-3/4
68-3/4
R
Manufacturer Certified to
ASSOCIATION OF HOME
APPLIANCE MANUFACTURERS
ANSI/AHAN HRF-1-1979
VOLUME and SHELF AREA
R
Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile™or GE appliance questions, call GE Answer Center®service, 800.626.2000.
Revised 2/99
TPX24SPBBS - GE Profile Performance™23.5 Cu. Ft. CustomStyle™Side-By-Side Refrigerator
Collar Trim Installation
Collar Trim Installation
An enclosure is required to match up to the trim, see Typical Installation. To obtain the most integrated look, the cabinet or soffit above the refrigerator should extend out to the same depth as the side panels. The refrigerator opening must have minimum dimensions of 70-1/4" high x 36-1/8" wide x 24-1/4"* deep as shown at right. If there is an overhead cabinet, allow 1" for cabinet door clearance with the top trim piece so the cabinet doors can be opened without hitting the top trim. If 1/2" side panels are used, then side trim and panel will be even. If 3/4" side panels are used, then some of the side panel will extend beyond the trim and must be finished.
70-1/4"*
36-1/8"
24-1/2"*
1/2" minimum
25" Counter Top
ElectricalWater
Trim
3/4" Airspace (1/2" Gap + 1/4" Wall Plates)
24-1/2"* Side panels
net
*24-1/4" depth applies only to the refrigerator opening,
not the actual cabinet depth.
Case
Overhead Cabinet
Top Trim
Cab Doo
1"
Typical Installation
Shaded areas represent front surfaces of side panels and overhead cabinet or soffit that contacts trim.
Refrigerator Case
Magnetic Tape
3/4" Cabinet Side Panel
1/2" Cabinet Side Panel
Door Gasket
Side Trim
Side trim must be installed flush with the gasket contact surface on the case.
Loading...