GE Tetra GEPS24W-80M Installation Manual

GE
Lighting Solutions
®
Tetra
(GEPS24W-80M)
Power Supply Features
• Supports Tetra PowerStrip DS, Tetra miniStrip DS, Tetra EdgeStrip, Tetra Contour and Tetra Contour LS LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• IP66 rated: wet location rated
• M20 Thread
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Installation Guide
24
Volt
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE:
• Use only approved wire for input/output connection. Minimum size 18 AWG (0.82 mm2)
• Follow all local codes.
Power Supply Installation
Power supply input wires
Conduit
AC Line
Run AC line through conduit and
1
attach conduit to outdoor-rated enclosure. Attach power supply to enclosure.
Power supply
NOTE: All electrical connections should be made within the letter.
White (-)
Connect the red stripe wire (+) of the
2
LED strip to the red wire (+) of the power supply. Connect the white wire (-) of the LED strip to the black wire (-) of the power supply.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que des ls approuvés pour les entrées/sorties de connexion. Taille minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.
Blue (+)
Green with
Red (+)
To power supply
Black (-) Red stripe (+)
Connect the AC line to the brown
3
(line) and blue (neutral) input wires of the power supply using 18-14 AWG (0.82-2.08 mm2) twist-on wire connectors. Properly ground (green wire with yellow stripe) power supply in accordance with National Electric Code (NEC) Article 600.
yellow stripe
Brown (-)
imagination at work
Mount power supply in a horizontal
4
orientation with a minimum of one screw per mounting plate (two
Tighten liquid-tight ttings and
5
properly replace cover on junction box to ensure a water-tight seal.
screws per power supply).
NOTE: Properly ground the power supply and sign in accordance with all local codes.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral
connections, in accordance with local, state or country regulations.
Power Supply Specications
Performance Data Min Typical Max
Input Voltage (VAC) 90 100-240 264
Input Frequency (Hz) - 50/60 -
Input Current (A) - - 1.2
Output Voltage (VDC) 23.0 24.3 25.6
Output Current (ADC) 0.6 - 3.3
Output Power (W) - - 80
Environmental Operating Temperature Range -40°C +25°C +60°C*
Environmental Humidity (non-condensing) 0% - 95%
Environmental Storage Temperature Range -40°C - +85°C
Dimensions 12 in. x 2.0 in. x 1.25 in. (307 mm x 52 mm x 32 mm)
* Maximum case temperature is 80°C
Supports Tetra Products SKUs
Tetra PowerStrip DS
Tetra miniStrip DS
Tetra EdgeStrip
Tetra Contour LS
Tetra Contour GEWHXNLE1, GEWWXNLE1, GEBLXNLE1, GEGLXNLE1,
GEWHDSPS6, GEWWDSPS6-50K, GEWWDSPS6-41K, GEWWDSPS6
GEWHBDP6, GEWWBDP6-50K, GEWWBDP6-41K, GEWWBDP6
GEWHBIP2, GEWWBIP2-50K, GEWWBIP2-41K, GEWWBIP2
GEWHXNLA2-WH, GEBLXNLA2-BL, GEGLXNLA2-GL, GERDXNLA2-RD, GEWHXNAA2-WH, GEBLXNAA2-BL, GEGLXNAA2-GL, GERDXNAA2-RD
GERDXNLE1, GERCXNLE1, GEYAXNLE1
Conforms to the following standards:
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Remote Mounting Distance
Maximum Load
per Power Supply
12 modules/
16.5 ft. (5.03 m) 31 modules/
31 ft. (9.45 m)
30 modules/
30 ft. (9.15 m)
24 ft. (7.32 m) 30 ft./9.1 m 50 ft ./15.2 m 80 ft./24.4 m 120 ft./36.6 m
24 ft. (7.32 m) 30 ft./9.1 m 50 ft ./15.2 m 80 ft./24.4 m 120 ft./36.6 m
18 AWG/
0.82 mm
20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
2
16 AWG/
1.31 mm
2
14 AWG/
2.08 mm
2
12 AWG/
3.31 mm
2
SIGN098-R012412