GE Tetra GEPS24-100U-GL, Tetra GEPS24-180U Installation Manual

GE
Lighting Solutions
®
Tetra
(GEPS24-100U-GL)
Power Supply Features
• Supports Tetra PowerStrip DS, Tetra miniStrip DS, Tetra EdgeStrip, Tetra Contour and Tetra Contour LS LED lighting systems
• UL: Class 2 wiring per NEC Article 725, dry and damp location rated
• IEC: SELV, CE: IP66 rated, separate enclosure required
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE:
• Use only Tetra® supply wire to make connection from Tetra® power supply to Tetra® LED strip.
• Use only approved wire for input/output connection. Minimum size 18 AWG (0.82 mm2)
• Follow all local codes.
LED Systems Power Supply
WARNING/AVERTISSEMENT
Installation Guide
Volt
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que le l d’approvisionnement Tetra® pour faire la connexion entre l’alimentation Tetra® et la bande DEL Tetra®.
• N’utilisez que des ls approuvés pour les entrées/sorties de connexion. Taille minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.
Power Supply Installation
Input wires
Brown (line)
Blue (neutral)
AC line
Connect the AC line to the brown
1
(line) and blue (neutral) input wires of the power supply using 18-14 AWG (0.82-2.08 mm2) or 18-10 AWG (0.82-5.26 mm2) twist-on wire connectors.
imagination at work
To Tetra LED System
Red (+)
Connect the supply wire that is
2
attached to the Tetra LED System to the red (+) and black (-) output wires of the power supply as outlined in the “Electrical Connections” section of your LED system’s Installation Instructions.
Black (-)
Output wires
NOTE: For CSA approval, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 ft. (9 m) of primary side of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch must also support twice the amount of input current.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral connections, in accordance with local, state or country regulations.
NOTE: The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code (NEC) Article 600.
Power Supply Specications
Performance Data Min Typical Max
Input Voltage (VAC) 108 120-277 305
Input Frequency (Hz) - 50/60 -
Input Current (A) 0.35 - 1.1
Output Voltage (VDC) 23 24 25
Output Current (ADC) - - 4.0
Output Power (W) - - 96
Environmental Operating Temperature Range -40°C +25°C +55°C*
Environmental Humidity (non-condensing) 0% - 95%
Environmental Storage Temperature Range -40°C - +85°C
Dimensions 9.5 in. x 1.7 in. x 1.2 in. (241 mm x 43.2 mm x 30.5 mm)
*Maximum case temperature is 85°C
GEPS24-100U-GL
Supports Tetra Products SKUs
Tetra PowerStrip DS
Tetra miniStrip DS
Tetra EdgeStrip
Tetra Contour LS
Tetra Contour GEWHXNLE1, GEWWXNLE1, GEBLXNLE1,
GEWHDSPS6, GEWWDSPS6-50K, GEWWDSPS6-41K, GEWWDSPS6
GEWHBDP6, GEWWBDP6-50K, GEWWBDP6-41K, GEWWBDP6
GEWHBIP2, GEWWBIP2-50K, GEWWBIP2-41K, GEWWBIP2
GEWHXNLA2-WH, GEBLXNLA2-BL, GEGLXNLA2-GL, GERDXNLA2-RD, GEWHXNAA2-WH, GEBLXNAA2-BL, GEGLXNAA2-GL, GERDXNAA2-RD
GEGLXNLE1, GERDXNLE1, GERCXNLE1, GEYAXNLE1
Remote Mounting Distance
Rated Watts
6W/mod
2.2W/mod
2.4W/mod
Maximum Load
per Power Supply
16 modules/
22.0 ft. (6.71m) 39 modules/
39 ft. (11.89m)
37 modules/
37 ft. (11.28m)
18 AWG/
0.82 mm
2
16 AWG/
1.31 mm
2
14 AWG/
2.08 mm
2
20 ft./6.1m 25 ft./7.6m 35 ft./10.6m 40 ft./12.1m
20 ft./6.1m 25 ft./7.6m 35 ft./10.6m 40 ft./12.1m
20 ft./6.1m 25 ft./7.6m 35 ft./10.6m 40 ft./12.1m
3.2W/ft. 29 ft. (8.84m) 30 ft./9.1m 50 ft ./15.2m 80 ft./24.4m 120 ft./36.6m
3.2W/ft. 29 ft. (8.84m) 30 ft./9.1m 50 ft ./15.2m 80 ft./24.4m 120 ft./36.6m
Conforms to the following standards:
12 AWG/
3.31 mm
2
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
SIGN112-R112612