GE Tetra GEPS12-60, Tetra GEPS12-60U Installation Manual

GE
Lighting Solutions
®
Tetra
(GEPS12-60 & GEPS12-60U)
Power Supply Features
• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX and Tetra PowerStrip LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• Damp location rated
• IP66 rated: separate enclosure required
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE:
• Use only Tetra® supply wire to make connection from Tetra® power supply to Tetra® LED strip.
• Use only approved wire for input/output connection. Minimum size 18 AWG (0.82mm2)
• Follow all local codes.
WARNING/AVERTISSEMENT
Installation Guide
12
Volt
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que le l d’approvisionnement Tetra® pour faire la connexion entre l’alimentation Tetra® et la bande DEL Tetra®.
• N’utilisez que des ls approuvés pour les entrées/sorties de connexion. Taille minimum 18 AWG (0.82mm2).
• Respectez tous les codes locaux.
Power Supply Installation
Input wires
Black (line)
White (neutral)
AC line
Connect the AC line to the black
1
(line) and white (neutral) input wires of the power supply using 18-14 AWG (0.82-2.08 mm2) or 18-10AWG (0.82-5.26 mm2) twist-on wire connectors.
imagination at work
To Tetra LED System
Red (+)
Connect the supply wire that is
2
attached to the Tetra LED System to the red (+) and black (-) output wires of the power supply as outlined in the “Electrical Connections” section of your LED system’s Installation Instructions.
Black (-)
Output wires
NOTE: Power Supply Loads
Exceeding maximum load will cause the power supply to shut down. Once the excess load is removed, cycle the input power to restart the power supply.
Specic load information for the supported LED systems can be found in the “Power Supply Specications” section on the next page.
NOTE: For CSA approval, a disconnect/ toggle switch of appropriate rating needs to be placed within 29 feet (8.84 meters) of primary side of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch must also support twice the amount of input current.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral connections, in accordance with local, state or country regulations.
NOTE: The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code (NEC) Article 600.
Power Supply Specications
Performance Data GEPS12-60 GEPS12-60U
Min Typical Max Min Typical Max
Input Voltage (VAC) 90 100-240 264 108 120-277 305
Input Frequency (Hz) - 50/60 - - 50/60 -
Input Current (A) - - 0.85 - - 0.61
Output Voltage (VDC) 11.4 12.0 12.6 11.5 12.0 12.5
Output Current (ADC) 0.8 - 5.0 0.8 - 5.0
Output Power (W) - - 60 - - 60
Dimensions 9.5 in. x 1.7 in. x 1.2 in. (240 mm x 43 mm x 30 mm)
Environmental Specications Min Typical Max
Environmental Operating Temperature Range -40°C +25°C +65°C*
Environmental Humidity (non-condensing) - - 95%
Environmental Storage Temperature Range -40°C - +85°C
*Maximum case temperature is 90°C
Load per Power Supply Min Max
Tetra miniMAX GEWHMMTS8, GEWWMMTS8 3 modules/1.2 ft. (0.37 m) 150 modules/60 ft. (18.29 m)
GEWHMMS6, GEWWMMS6 3 modules/1 ft. (0.30 m) 120 modules/40 ft. (12.20 m)
GEBLMMS5, GEGLMMS5, GERDMMS5 3 modules/1.2 ft. (0.37 m) 90 modules/36 ft. (10.97 m)
Tetra MAX GEWHMXTS6, GEWWMXTS6 2 modules/1 ft. (0.30 m) 120 modules/60 ft. (18.29 m)
GEWHMHTS6, GEWWMHTS6 2 modules/1 ft. (0.30 m) 80 modules/40 ft. (12.20 m)
GEWHMXWA5, GEWWMXWA5, GEBLMXWA5, GEGLMXWA5, GERDMXWA5
GERCMXWA6, GEYGMXS6 3 modules/1 ft. (0.30 m) 162 modules/54 ft. (16.46 m)
GERCMXWL6 2 modules/1 ft. (0.30 m) 160 modules/80 ft. (24.38 m)
GERDMXWL6 2 modules/1 ft. (0.30 m) 140 modules/70 ft. (21.34 m)
Tetra PowerMAX GEWHPMTL5, GEWWPMTL5 2 modules/1.3 ft. (0.41 m) 38 modules/25 ft. (7.62 m)
GEWHPMS2-65K, GEWWPMS2-30K 2 modules/1 ft. (0.30 m) 50 modules/25 ft. (7.62 m)
Tetra PowerStrip GEWHSSP3-65K, GEWWSSP3-41K 1 module/1 ft. (0.30 m) 16 modules/16 ft. (4.88 m)
3 modules/1.2 ft. (0.37 m) 135 modules/54 ft. (16.46 m)
18 AWG
Maximum Remote Mounting Distance
Tetra miniMAX 30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m - -
Tetra MAX 30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m - -
Tetra PowerMAX GEWHPMTL5, GEWWPMTL5 30 ft ./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m - -
GEWHPMS2-65K, GEWWPMS2-30K
Tetra PowerStrip 30 ft./9.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m 75 ft./22.8 m 100 ft./30.5 m
(0.82 mm2)
15 ft./4.5 m 20 ft./6.1 m 30 ft./9.1 m 60 ft./18.2 m - -
16 AWG
(1.31 mm2)
14 AWG
(2.08 mm2)
12 AWG
(3.31 mm2)
10 AWG
(5.27 mm2)
8 AWG
(8.35 mm2)
Conforms to the following standards:
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company. © 2011 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.