(GEPS12-180U)
Power Supply Features
• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX, Tetra PowerStrip and Tetra miniStrip lighting systems
• Class 2 wiring per NEC Article 725 (SELV equivalent)
• Damp location rated
• IP66 rated: separate enclosure required
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE:
• Use only Tetra® supply wire to make connection from Tetra® power supply to Tetra® LED strip.
• Use only approved wire for input/output connection. Minimum size 18 AWG (0.82 mm2)
• Follow all local codes.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que le l d’approvisionnement Tetra® pour faire la connexion entre l’alimentation Tetra® et la bande DEL Tetra®.
• N’utilisez que des ls approuvés pour les entrées/sorties de connexion. Taille minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.
Power Supply Installation
Mount power supply and remove
1
junction box cover. Carefully remove knockout for AC line input wires. Install appropriate electrical ttings in the knockout holes for wire protection.
imagination at work
To Tetra LED System
Output wires
Connect the supply wire that is
2
attached to the Tetra LED System to the red (+) and black (-) output wires of the power supply as outlined in the “Electrical Connections” section of your LED system’s Installation Instructions.
NOTE: Three 60 watt output banks per power supply. Do not interconnect output terminations.
Green with yellow stripe (ground)
AC line
White (neutral)
Connect the AC line to the black
3
(line) and white (neutral) input wires of the power supply using 18-14 AWG (0.82-2.08 mm2) twist-on wire connectors. Ground power supply by connecting green wire with yellow stripe to grounding screw. Replace junction box cover.
Black (line)
NOTE: For installation in Canada, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 feet (9 meters) of primary side of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch must also support twice the amount of input current.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line, neutral and ground connections, in accordance with National Electric Code (NEC) Article 600 and all local regulations.
NOTE: Exceeding maximum load per bank will cause the power supply to shut down. Once the excess load is removed, cycle the input power to restart the power supply.
Power Supply Specications
Performance Data Min Typical Max
Input Voltage (VAC) 90 100-240 305
Input Frequency (Hz) - 50/60 -
Input Current (A) 0.70 - 2.50
Output Voltage (VDC) 11.64 12.0 12.32
Output Current (ADC) - - 5.0
Output Power (W) - - 180
Environmental Operating Temperature Range -40°C +25°C +60°C*
Environmental Humidity (non-condensing) 10% - 90%
Environmental Storage Temperature Range -40°C - +85°C
Environmental Rating IP66 rated: separate enclosure required
Dimensions 12 in. x 2.7 in. x 1.6 in. (305 mm x 68 mm x 40 mm)
*Maximum case temperature is 80°C
Supports Tetra Products SKUs
Tetra miniMAX
GEWHMMTS8, GEWWMMTS8-50K, GEWWMMTS8-41K, GEWWMMTS8
GEBLMMS5, GEGLMMS5, GERDMMS5
Tetra MAX GEWHMXTS6, GEWWMXTS6-50K,
GEWWMXTS6-41K, GEWWMXTS6 GEWHMHTS6, GEWWMHTS6-50K,
GEWWMHTS6-41K, GEWWMHTS6 GEBLMXWA5, GEGLMXWA5,
GERDMXWA5 GERCMXWA6, GEYGMXS6 162 modules/54 ft. (16.46 m) per bank;
GERCMXWL6 160 modules/80 ft. (24.38 m) per bank;
GERDMXWL6 140 modules/70 ft. (21.34 m) per bank;
Tetra PowerMAX
Tetra PowerStrip
Tetra miniStrip
GEWHPMTL5, GEWWPMTL5-50K, GEWWPMTL5-41K, GEWWPMTL5
GEWHSSPS3, GEWWSSPS3-50K, GEWWSSPS3-41K, GEWWSSPS3
GEWHBSP3, GEWWBSP3-50K, GEWWBSP3-41K, GEWWBSP3
Maximum Load
per Power Supply
150 modules/60 ft. (18.29 m) per bank;
450 modules/180 ft. (54.88 m) per PS
90 modules/36 ft. (10.97 m) per bank;
270 modules/108 ft. (32.93 m) per PS
120 modules/60 ft. (18.29 m) per bank;
360 modules/180 ft. (54.88 m) per PS
80 modules/40 ft. (12.20 m) per bank;
240 modules/120 ft. (36.59 m) per PS
135 modules/54 ft. (16.46 m) per bank;
405 modules/162 ft. (49.39 m) per PS
486 modules/162 ft. (49.39 m) per PS
480 modules/240 ft. (73.17 m) per PS
420 modules/210 ft. (64.02 m) per PS
38 modules/25 ft. (7.62 m) per bank;
114 modules/75 ft. (22.87 m) per PS
16 modules/17 ft. (5.18 m) per bank;
48 modules/51 ft. (15.55 m) per PS
53 modules/53 ft. (16.16 m) per bank;
159 modules/159 ft. (48.48 m) per PS
Remote Mounting Distance
18 AWG/
0.82 mm
2
16 AWG/
1.31 mm
2
14 AWG/
2.08 mm
12 AWG/
2
3.31 mm
2
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
30 ft./9.1 m 50 ft./15.2 m 80 ft./24.4 m 120 ft./36.6 m
20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
Conforms to the following standards:
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.