GE Tetra Contour LS Installation Manual

GE
Installation Guide
Lighting Solutions
®
Tetra
Contour LS
LED Lighting System
Tools and Components
1
2
4
Tools required:
1
Wire stripper/cutter
Tape measure
2
Electrical grade silicone
3
Cordless drill
4
24
Volt
6
1
7
9
2
10
3
3
8
Components required:
4
) m 4 4 . 2 ( t e e f 8
) m m 6 0 4 ( s e h c n i 6 1
5
UL approved 18 AWG (0.82mm
1
supply wire
End Caps
2
Weather Boxes
3
Light Guide Mounting Clips
4
2
22 AWG (0.33mm
5
#6, #8 or #10 (M2, M3 or M4) self
6
drilling pan headed screws
UL approved twist-on wire
7
connectors fitting both 18 and 20 AWG wire (0.82mm
®
Tetra 24 Volt Power Supply
8
®
Contour LS
Tetra
9
Optional: Tetra
10
extension
) tie-wire
2
, 0.52mm 2 )
®
Contour LS
2
imagination at work
Planning
For planning the layout, measure the perimeter of the building and divide by 8 ft . (2.44m) to determine the required quantity of Tetra Contour LS systems. See table
For seamless designs, accessories are available for straight runs and 90 degree corners.
NOTE: Do not use more than one suffix code for each respective application, as mixing suffix codes may result in appearance variation. Suffix code can be found on the packaging label.
Tetra Contour LS Tetra Contour LS extension
SKU Color Cutting Resolution
GERDXNLA2 - RD Red GEGLXNLA2 - GL Green 8 inches (203mm) GEBLXNLA2 - BL Blue 8 inches (203mm) GEWHXNLA2 - WH White 8 inches (203mm)
Tetra Contour LS
Tetra Contour LS extension
below for guidelines about cutting resolution.
Cutting Resolution Table
SKU Color Cutting Resolution
8 inches (203mm)
GERDXNAA2 - RD Red 2.67 inches (68mm) GEGLXNAA2 - GL Green 2.00 inches (51mm) GEBLXNAA2 - BL Blue 2.00 inches (51mm) GEWHXNAA2 - WH White 2.00 inches (51mm)
If it is necessary to cut the Tetra Contour LS for a better fit,
1
refer to the Cutting Resolution table above.
NOTE: Tetra Contour LS can only be cut on wires.
NOTE: Tetra Contour LS extension sections can only be cut
on “Cut Here” markings.
Attaching Contour Sections
NOTE: Tetra Contour LS is intended for straight runs.
Space mounting clips 18 inches (457mm) apart
Electrical Grade Silicone
If Tetra Contour LS sections are cut, apply electrical grade
2
silicone to exposed wires and attach end cap.
CAUTION
Risk of damage. Must use electrical grade silicone.
Install one mounting clip at each end and then a minimum of one mounting clip every 18 inches (457mm).
NOTE: Standard neon mounting hardware can also be used.
Starting from one end, attach the Tetra Contour LS to the
2 1
mounting clips. Secure light guide by twisting tie-wire around the mounting clip and light guide.
NOTE: Wires can be concealed by tucking wires between mounting clips and Tetra Contour LS system.