GE Spring Wound Timer 15305 Owner's Manual

INSTRUCTIONS
CAUTION:
Installation by a licensed electrician is recommended. Installation and use of this equipment should be in accordance with provisions of the U.S. National Electrical Code, applicable local codes and pertinent industry standards.
These timers are not to be used in precision timing applications when inaccurate timing could have dangerous consequences such as with sun lamps or in tanning booths.
Do not use to control receptacles.
For indoor use only unless installed in a, NEMA type 3R enclosure.
WALL BOX TIME SWITCH
15305
Specifications:
20A, 125VAC General Purpose 10A, 250VAC General Purpose 10A, 277VAC General Purpose 7A, 125VAC Tungsten 1HP, 125VAC 1HP, 250VAC
Installation Instructions
This GE Spring Wound Timer is easy to install and will fit in any standard 2-1/2 inch deep wall box. Timer fits both toggle switch and rocker/decorator switch applications in a single or multi gang vertically installed box setup. Timer will work in single pole, 3-Way, or reverse acting applications. If you are unsure about the installation of this timer please contact a licensed electrician.
1. Turn power off at circuit breaker or fuse box before installation.
2. Remove current wall plate and current switch from vertically installed wall box.
3. Wires should be stripped 5/16 inch long. Wire Strip gauge on back of timer may be used to measure 5/16 inch.
4. Attach wires to timer by sliding the stripped end of the wires into the timer terminals. Be sure and note the proper wiring for your particular application. See “Applications” section of this manual for more information. Screw terminals down tight to secure the wires to the timer. (See Image Below)
5. Attach ground wire (green) to bare ground in wire box. Use included wire nut and twist together see image of typical SPST installation.
Typical SPST Installation
6. Insert timer into the 2-1/2” wall box being careful not to pinch any wires. Be sure the TOP (indicated on front of timer) is facing up. Fasten the timer to the wall box using the screws provided.
7. Place provided metal wall plate on timer referring to the appropriate diagram below.
* Note – Ground and Neutral are not used by the timer.
Nut
Wire Termin al
Mount ing Screw
2½” min
Knob
NOTE: When using the provided wall plate, screws are not required in order to secure the wall plate. The nut will hold the wall plate in position once assembled.
= Wiring Nut
SPST Wiring Example
Black
Black
Black
Light
WhiteWhite
120 VAC
Power
Source
Spring Wound Timer
Load 1NOLine 2
C
Line 1CLoad 2
NC
8. Carefully screw on the provided nut.
9. Push timer knob onto knob extension. Be sure the pointer is lined up with “OFF” on dial plate.
10. Turn power on at the circuit breaker or fuse box.
Operating Instructions
Turn knob clockwise to desired time period. Timer will automatically turn current off at end of period.
Applications
This timer has multiple pole configurations including SPST, SPDT (3-Way), and DPST. Please see below for an explanation.
SPST (Lighting, Fans, A/C Units, Small Appliances) SPDT (Hallways, Multi-Levels, Large Rooms)
SPST Wiring Example
120/277 VAC
Power Source
REVERSE ACTING (Load always on except when timer is engaged)
= Wiring Nut
Black
SPDT Wiring Example
= Wiring Nut
Spring Wound Timer
Load 1NOLine 2
Line 1CLoad 2
C
Black
Black
120 VAC
NC
Light
Power
Source
WhiteWhite
Black
NC
HOT
Spring Wound Timer
Load 1NOLine 2
C
3 Way Switch
NO
Line 1CLoad 2
NC
* For 3-Way Applications a jumper wire must be connected from Line 1
to Line 2. This is represented by the dashed line in the above diagram.
WhiteWhite
Black
Light
15304 Manual
www.jascoproducts.com/timer