GE SpacemakerXL JVM1440WA, SpacemakerXL JVM1440BA Dimensions

JVM1440WA—GE SpacemakerXL 1.4 Cu. Ft. Microwave Oven
Dimensions (in inches)
GE Appliances
Note: Requires 120V grounded outlet. Electrical receptacle must be
located in cabinet above SpacemakerXL microwave oven. No additional wiring, venting or cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the SpacemakerXL microwave oven.
Ventilation Options: The SpacemakerXL microwave ovens are designed for adaptation to the following three types of ventilation:
• Outside exhaust (vertical—as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless—see Filter Kit drawing) Installation Information: This information is not intended to be used for
installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
21-3/4"
Door open
16-1/2
66" MIN.
Mounting
height
from floor
30" MIN.
width required
MAX.
Exhaust outlet
connects to
3-1/4" X 10" duct
12"
15-3/4
15
Revised 2/99
R
Listed by Underwriters Laboratories
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile™or GE appliance questions, call GE Answer Center®service, 800.626.2000.
JVM1440WA—GE SpacemakerXL 1.4 Cu. Ft. Microwave Oven
GE Appliances
Revised 2/99
R
Listed by Underwriters Laboratories
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile™or GE appliance questions, call GE Answer Center®service, 800.626.2000.
Optional Accessories (Available at additional cost)
JX22SS–Stainless Steel Decorative Panel Kit
When replacing a Hi/Low range with a SpacemakerPlus™ microwave/convection oven or Spacemaker XL1400 over a range model, this panel kit fills in the area between the microwave and range left by the Hi/Low model.
19
30
3/8" depth
HOOD EXHAUSTDUCT
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully. EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4” x 10”
rectangular duct.If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct
REAR EXHAUST:If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs,or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS,WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct Equivalent Feet
A. Rectangular-To-round 5ft.
Transition Adaptor
B. Wall Cap 40ft. C. 90° Elbow 10ft. D. 45° Elbow 5ft. E. 90° Elbow 25ft. F. 45° Elbow 5ft. G. Roof Cap 24ft.
12" Filler Panel Kits JX40AL–Almond JX41–Black JX40WH–White
15" Filler Panel Kits JX46BL–Black JX46AL–Almond JX46WH–White
When replacing a 36" or 42" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between cabinets only; not for end-of-cabinet installation. Each kit contains two 3"-wide filler panels. Two kits are needed for a 42" opening.
Filter Kits JX81A–Recirculating
Charcoal Filter Kit
To be used when the Spacemaker microwave oven cannot be vented to the outside.
JX81–Recirculating Charcoal Filter Kit
To be used when the SpacemakerPlus™ microwave/convection oven cannot be vented to the outside.