Dimensions (in inches)
Note: Requires 120V grounded outlet. Electrical receptacle must be
located in cabinet above Spacemaker microwave oven. No additional
wiring, venting or cabinet rebuilding necessary in many cases. Complete
detailed, easy-to-follow installation instructions and convenient full-size
templates are packed with the Spacemaker microwave oven.
Important Information: When installing the Spacemaker microwave oven
over a range, allow minimum of 2" from bottom of Spacemaker microwave
oven to top of range backguard to allow for removal of light covers.
Ventilation Options: The Spacemaker microwave ovens are designed for
adaptation to the following three types of ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless – see Filter Kit drawing)
Installation Information: This information is not intended to be used for
installing unit described. Before installing, consult installation instructions
packed with product/kit for current dimensional data.
21-3/4"
Door open
16-1/2
66" MIN.
Mounting
height
from floor
30" MIN.
width required
MAX.
Exhaust outlet
connects to
3-1/4" X 10" duct
12"
15-3/4
15
Specification Revised 1/03
For answers to your Monogram,®GE Profile™or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center®service, 800.626.2000.
Listed by
Underwriters
Laboratories

GE AppliancesGE Appliances
JVM1630BB – GE 1.6 Cu. Ft. Spacemaker Over-the-Range Microwave Oven
Specification Revised 1/03
Optional Accessories (Available at additional cost)
JX22SS – Stainless Steel Decorative Panel Kit
When replacing a Hi/Low range with a microwave/convection oven or Spacemaker over
a range model, this panel kit fills in the area between the microwave and range left by
the Hi/Low model.
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6” diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it is
constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of
3-1/4" x 10" rectangular or 6” diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS,WALL AND ROOF CAPS, etc., present additional resistance
to airflow and are equivalent to a section of straight duct which is longer than their actual
physical size. When calculating the total duct length, add the equivalent length of all
transitions and adaptors plus the lengths of all straight duct sections. The chart below
shows the approximate feet of equivalent length of some typical ducts.
12" Filler Panel Kits
JX40AL – Almond
JX41 – Black
JX40WH – White
15" Filler Panel Kits
JX46BL – Black
JX46AL – Almond
JX46WH – White
When replacing a 36" or 42"
range hood, this kit fills in the
additional width to provide a
custom built-in appearance.
For installation between cabinets
only; not for end-of-cabinet installation.
Each kit contains two 3"-wide filler panels.
Two kits are needed for a 42" opening.
Filter Kits
JX81A – Recirculating
Charcoal Filter Kit
To be used when the
Spacemaker microwave
oven cannot be vented
to the outside.
Listed by
Underwriters
Laboratories
For answers to your Monogram,®GE Profile™or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center®service, 800.626.2000.
Duct Equivalent Feet
A. Rectangular-To-round 5 ft.
Transition Adaptor
B. Wall Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.