Any GE Security software supplied with GE Security
products is proprietary and furnished under license and
can be used or copied only in accordance with the terms
of such license.
This document contains proprietary information that is
protected by copyright. No part of this document may be
reproduced or transmitted in any form or by any means
without the prior written permission of GE Security.
The information contained in this document is subject to
change without notice. GE Security in keeping pace with
technological advances is a company of product
innovation. Therefore, it is difficult to ensure that all
information provided is entirely accurate and up-to-date.
GE Security accepts no responsibility for inaccuracies or
omissions and specifically disclaims any liabilities,
losses, or risks, personal or otherwise, incurred as a
consequence, directly or indirectly, of the use or
application of any of the contents of this document.
For the latest product specifications, visit GE Security
online at www.GE-Security.com or contact your GE
Security sales representative.
This equipment has been tested and
found to comply with the limits for a
Class A digital device, pursuant to part
15 of the FCC Rules. These limits are
designed to provide reasonable
protection against harmful interference
when the equipment is operated in a
commercial environment. This
equipment generates, uses, and can
radiate radio frequency energy and, if
not installed and used in accordance
with the instruction manual, may cause
harmful interference to radio
communications.
You are cautioned that any changes or
modifications not expressly approved by
the party responsible for compliance
could void the user's authority to
operate the equipment.
For technical support before and after installation, call
800-469-1676.
Technical support is available 24 hours a day, 7 days a week.
Call: Tech Support 800-469-1676 (6 A.M. – 5 P.M. PST
Monday through Friday)
Tech Support 541-740-3589 (all other times)
Main800-343-3358 or 541-754-9133
Fax: Tech Support 541-752-9096 (available 24 hours a
11 Warranty and Service.......................................................................................... 92
11.1 Factory Service ............................................................................................................... 92
11.2 Warranty and Return Information...................................................................................93
0150-0193G 5 DVMRe Triplex
1 DVMRe Triplex Overview
1.1 Products Featured In This Manual
DVMRe -4CT: Digital Video Multiplexer Recorder, Four-Channel, Color, Triplex.
DVMRe -10CT: Digital Video Multiplexer Recorder, Ten-Channel, Color, Triplex.
DVMRe -16CT: Digital Video Multiplexer Recorder, Sixteen-Channel, Color, Triplex.
Key To Model Numbers
1. DVMRe: Digital Video Multiplexer Recorder, Ethernet capable.
DVMRe 16 C T
2. 4, 10, or 16: Maximum number of camera inputs.
3. C: Color.
4. T: Triplex.
1 2 3 4
1.2 Product Description
The DVMRe Triplex is a video multiplexer capable of recording from multiple cameras to one or more
internal hard drives while simultaneously providing playback. Unlike outdated time-lapse VCRs, the
DVMRe Triplex records high-resolution pictures. Digital recording improves playback quality over
VCRs, and eliminates the hassle of cleaning heads, changing tapes or servicing motors. The unit can
also be programmed to record continuously by overwriting the oldest recorded data. Depending on
the setup, the DVMRe Triplex can store from a few hours to more than 3 years of color images.
Programmable search features eliminate time consuming Fast Forwarding or Rewinding of tapes,
searching for critical data. Search for recorded images or events by alarm, time, date, motion, video
loss, camera number and ASCII cash register or ATM text.
Caution! This products primary purpose is to furnish video multiplexing and recording.
Although the unit has alarm handling and motion detection functions, they are considered
secondary features. This unit should not be the only alarm device on site.
Features
• Multiplexer functionality with built-in digital recording.
• Triplex simultaneous recording, playback, and live multiscreen viewing.
• Remote programming and control through the RS232, RS485 and Ethernet ports.
• View live or recorded images remotely using WaveReader software.
• Dual multiscreen monitor displays.
• Auto-detect video mode on startup (NTSC or PAL).
• Video motion detection (intrusion and activity).
• Retail and Motion search.
• Preview search results with thumbnail images.
• Record speed selectable per camera.
• Displays include full screen, sequenced, picture-in-picture, and multiscreens.
• Alarm Handling with History Log. Pre- and post alarm recording, selectable per camera.
• Archive onto GE Security DVSe Disk Array, or RAID, DAT, AIT, or CD-Rs.
• IEEE 1394 Firewire interface for GE Security DVSe Disk Array or Firewire Disk Drives.
• Continuous Recording with simultaneous Archiving.
• PTZ control via ethernet or POTS, using CBR-KB3/J or KTD-405 keypad.
• Covert camera recording (recording without display).
0150-0193G 6 DVMRe Triplex
• Auto-Daylight savings time change function.
• Clock synchronization with Network Server.
• Alarm Notification via email and/or TCP/IP.
• Integrated WaveBrowser Software.
• Dynamic IP addressing (DHCP).
• Support for Dynamic Domain Name Server (DDNS).
• One-touch image printing directly from the DVMRe.
• Support for over a dozen languages.
• Hard Disk monitoring and testing features.
• Playback and live audio via WaveReader on audio supported models.
1.3 Passwords
Passwords are provided to limit access to menus and certain functions. Two levels of password
security are provided:
• Operator: Limited menu access, only Operator and System View menus are available.
• Installer: Complete menu access.
As a security measure, it is recommended that the Operator and Installer passwords be changed after
installation is complete (see section 3.20). Store the passwords in the administrator’s secure files.
Default Passwords
Four-Channel Units
Password
Type
Operator
Installer
Factory
Defaults
Language
Ethernet
Access
Reset
Access
Level Function
Operator
Installer
Installer
Installer
Installer
Provides access to the Operator
and SystemView menus.
Provides access to all on-screen
menus.
Resets the multiplexer to the
factory defaults (except the time,
date, email addresses, and email
IP address).
Provides access to the On-screen
Language menu.
Deactivates the ethernet
password, so that the unit may be
accessed by any PC equipped with
WaveReader.
Changeable
by user?
Yes
Yes
No
No
No
Default
Password
Press ‘ENTER’
4 Times
3 4 4 4
4 1 1 1
1 4 1 4
1 1 1 1
0150-0193G 7 DVMRe Triplex
Ten and Sixteen-Channel Units
Password
Type
Operator
Installer
Factory
Defaults
Language
Ethernet
Access
Reset
Access
Level
Operator
Installer
Installer
Installer
Installer
Function
Provides access to the Operator
and SystemView menus.
Provides access to all on-screen
menus.
Resets the multiplexer to the
factory defaults (except the time,
date, email addresses, and email
IP address).
Provides access to the On-screen
Language menu.
Deactivates the ethernet
password, so that the unit may be
accessed by any PC equipped with
WaveReader.
Changeable
by user?
Yes
Yes
No
No
No
Default
Password
Press ‘ENTER’
4 Times
3 4 7 7
8 1 1 1
5 4 1 5
1 1 1 1
1.4 Unpacking
Check the package and contents for visible damage. If any components are damaged or missing, do
not attempt to use the unit, contact the supplier immediately. If the unit must be returned, it must be
shipped in the original packing box.
Package Contents
• The DVMRe Triplex unit.
• The Alarm Interface Circuit Board (P/N 0090-0077).
• Power Cords (120 VAC P/N 4310-0002) and (220 VAC P/N 4310-0001).
1.5 Installation Environment
Power: Ensure that the installation site’s AC power is stable and within the rated voltage of the 12
Volt DC power supply. If the site’s AC power is likely to have spikes or power dips, use power line
conditioning or an Uninterruptable Power Supply (UPS).
Ventilation: Ensure that the location planned for the installation of the unit is well ventilated. Take
note of the locations of the cooling vents in the unit’s enclosure, and ensure that they are not
obstructed.
Temperature: Consider the unit’s operating temperature (0 to 40 °C) and non-condensing humidity
specifications (10% to 80%) before choosing an installation location. Extremes of heat or cold beyond
0150-0193G 8 DVMRe Triplex
the specified operating temperature limits may cause the unit to fail. Do not install the unit on top of
B
B
RS-485/1
ETHERNET
RS-485/2
RS-232/2
2345678
9
131415
other hot equipment. Leave space between rack mounted units.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage the internal components.
Do not install the unit near sources of water.
Chassis: Other equipment may be placed on top of the unit if it weighs less than 35 pounds (16
kilograms).
1.6 Associated Equipment
Associated equipment in a typical security system could contain the following items:
• Two monitors
• A Keyboard (KB3 or KTD405).
• Video cameras: Composite video, 1 volt peak-to-peak.
• Alarm input devices: Pressure sensors, motion detectors, etc.
• Alarm output devices: Buzzers, Sirens, Flashing Lights, etc.
• A PC connected via ethernet cable.
• An external archive device, such as a DVSe, RAID, CD-R, DAT, or AIT drive.
• Printer with Printer Server connected via ethernet cable.
For instructions regarding the connection of the associated security equipment in your system, please
consult the instruction manual of the associated equipment.
1.7 The Back Panel
1
AUX
12345678910111213141516
SVHS
101112
SCSI
1. Camera Inputs: BNC connector, looping. Auto Terminating.
2. Composite Monitor-A Output: Composite video output with BNC style connector.
3. Y/C Monitor-A Output: Y/C video output with 4-pin mini-DIN style connector.
4. Alarm I/O: For connecting alarm inputs, and alarm output relays.
5. Power Input: For connecting the power supply.
6. Aux Port: For connecting the Accessory PCB for Audio inputs and outputs.
7. RS485 Port 1 Connector: For connecting to keyboard and other RS485 devices.
8. 10/100 Ethernet Port: For connecting to remote PC via ethernet network.
12V DC
IEEE-1394
RS-232/1
10/100
9. Composite Monitor-B Output: Composite video output with BNC style connector.
10. Y/C Monitor-B Output: Y/C video output with 4-pin mini-DIN style connector.
11. SCSI Port: For connecting SCSI compatible archive devices.
13. RS232 Port 1: For modem connection and external control of the unit.
0150-0193G 9 DVMRe Triplex
14. RS485 Port 2 Connector: For connecting to keyboard and other RS485 devices.
15. RS232 Port 2: For Event Generation and ASCII Text insertion.
Camera Inputs
There are two BNC jacks for each camera. Either
jack can receive a camera signal. The signal is
looped (directly connected to the other jack), making
the camera signal available to other equipment.
Cable: 75-Ohm Coaxial
Connectors: BNC
Auto Terminating: Yes
The camera input connectors are Auto Terminating.
Passive Looping: Yes
This means that the input signal will automatically be terminated with 75-Ohms unless a 2nd cable is
connected to the 2nd BNC connector of the same camera input. Make sure there is 75-Ohm
termination at the end of the video line if the signal is looped through the DVMRe Triplex.
Time base correction is performed during digital capture. As a result, cameras do not require
synchronization.
See section 3.14 for information about disabling unused camera jacks in the menu system.
Composite Monitor Output
When connecting directly from the DVMRe Triplex to
the monitor, select the 75-Ohm impedance setting on
the monitor.
If an additional device is connected to the monitor’s looping output, set the termination of the additional
device as 75-Ohm, and set the termination of the monitor as Hi-Z (High Impedance).
Cable: 75-Ohm Coaxial
Connectors: BNC
Y/C Monitor Output
Y/C video output has a 4-pin mini-DIN style
connector. This style of connection is also referred to
as SVHS and S-Video.
Cable: 75-Ohm Coaxial
Connectors: BNC
Alarm I/O Port
The back panel of the unit is equipped with an Alarm
Port (DB-25 style connector).
Do not attempt to wire directly to the DB-25
connector on the back panel.
Connect the Alarm PCB (supplied with the unit) to the Alarm Port. Wire all alarm inputs to the Alarm
PCB per the pin out specifications shown below.
Pin 23: External Alarm Silence and Acknowledge Input.
Pin 25: Alarm Output Relay #2 Common.
Signal
PIN
NO1A1A2A14A15A16A3A4A5 GND
1712141516345 187196
GNDA6
Alarm PCB
Active alarm inputs vary by DVMRe model. 4 channel units (4CT) have 4 active alarm inputs. 10
channel units (10CT) have 10 active alarm inputs.
Alarm Input
An alarm condition can be activated by devices such as pressure pads, passive infrared detectors,
door switches, or other similar devices.
Signal
PIN
NO2COM1
2221208910202311241213 25
A8A9A10GNDACKA11VextA12A13 COM2
See section 3.11 for information about configuring the contacts as Normally Open or Normally Closed
in the menu system.
Normally Open, Zero Potential Relay Contact: Configure in menu as Normally Open.
Normally Closed, Zero Potential Relay Contact: Configure in menu as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
TTL Active Low: Configure in menu as Normally Open.
Open Collector Active On: Configure in menu as Normally Open.
High: 5V (12V Tolerant)
Low: Ground
Inputs: 1 per channel.
Open Collector Active Off: Configure in menu as Normally Closed.
Alarm Input No. 1
Alarm Input No. 2 - 15
pin 1
pins 2-15
pin 16
Normally Open
Typical Alarm Device
Refer to each alarm device's manual for specific wiring details.
(Opens During Alarm)
Typical wiring for Alarm #1 as Normally
Open and Alarm #16 as Normally Closed.
Typical Alarm Device
0150-0193G 11 DVMRe Triplex
Normally Open and Normally Closed Connections
Alarm Relay Output
Output Relay No. 2
Output Relay No. 1
1
5
6
9
The alarm relay output is activated when an alarm condition
exists. The alarm output is only active for the duration of the
alarm.
Output: Zero potential relay contacts,
programmable in menu system as
Normally Open or Normally Closed.
Alarm relays can be programmed in the menu system to
respond to macros, and video loss. See section 3.11 for
information about configuring the alarms in the menu system.
Typical wiring for Alarm Relays. Relays may be
programmed Normally Open or Normally Closed.
pin 17
pin 21
pin 22
pin 25
DVMRe Triplex DB25 Connector
Alarm
Device
Controlled
Device
External Alarm Acknowledge Input
Connect a switch or similar device to ground this pin in order
to acknowledge an alarm condition, and silence associated
buzzers and relays. Connect from pin 23 to either pin 18, 19,
or 20 (ground pins).
Voltage: 30V (Max)
Current: 500mA (Max)
Power
Source
Power
Source
External Device: Normally Open
Zero potential relay contact.
NOTE
All specifications subject to change without notice. GE Security believes all specifications
to be correct at time of printing, but no liability is assumed for omissions or errors.
AUX Port
The back panel of the unit is equipped with an Aux Port
(DB-9 style connector).
Do not attempt to wire directly to the DB-9
connector on the back panel.
Connect the Accessory PCB (supplied with the audio equipped models) to the AUX port to access the
Audio features. Wire the audio input and output to the Accessory PCB per the pin out specifications
shown below.
Warning! The use of clandestine listening and recording devices is forbidden by
Federal Law as well as other State and Municipal Jurisdictions. Please review local and
Federal Law prior to the installation or operation of this equipment to ensure that you
are in legal compliance with the Authorities having Jurisdiction.
DB-9 Connector on Back Panel
0150-0193G 12 DVMRe Triplex
Pin 1: Not Used.
123456789
GND
#24 AWG, twisted pair with shield
Pin 2: Audio Out.
Pin 3: Ground.
Pin 4: Audio In.
Pin 5: Ground.
Pin 6: Not Used.
Pin 7: Ground.
Pin 8: Not Used.
Pin 9: Ground.
GND: Ground.
RS485 Connector
Shields are grounded at one end, preferably at the
DVMRe Triplex.
Accessory PCB
Wire Type:
(2-wire)
See section 3.17 for information about configuring
the RS485 network address settings in the menu
system.
1 Ground (Shield) 5 Not Connected
2 Not Connected 6 Network -VE
3 Network +VE 7 Ground (Shield)
4 Not Connected 8 Not Connected
Pin Use
Ethernet Port
The cable connection configuration depends on your
network configuration:
• For a DVMRe Triplex that connects directly to a
Hub or Switch, use a straight through connection.
• For a DVMRe Triplex that connects directly to a
PC, use a cross over connection.
Consult with your MIS personnel for the specific type
of configuration. See section 3.17 for information
about configuring the ethernet settings in the menu
system.
Wire Type: Cat 5
Connector Type: RJ-45
Max. Cable Length: 100 meters / 328 ft.
Min. Cable Length: 6 feet / 1.8 meters
Hub Wiring Configuration: Straight Through
PC Wiring Configuration: Cross Over
82 3 4 5 6 71
RJ-45 socket on
back panel.
0150-0193G 13 DVMRe Triplex
RJ-45 Pin Configuration For Ethernet Port
, RAID, DAT, AIT,
Pin Use
1 TX+ 5 Not Connected
2 TX- 6 RX-
Pin Use
82 3 4 5 6 71
3 RX+ 7 Not Connected
4 Not Connected 8 Not Connected
SCSI and IEEE 1394 archiving devices should not be connected to the DVMRe Triplex
NOTE
simultaneously. Archiving support is only available for one or the other type of interface at a
time.
SCSI Port
The unit is equipped with a SCSI port for
connecting external archive devices. The unit only
supports a single SCSI device. The SCSI ID of the
archive device must be set to 0.
The SCSI bus must be terminated, otherwise the
system will not operate properly.
Additional menu setup may be necessary to
configure archive device. See section 3.15.
Connector: 50 Pin, High Density SCSI-2.
Gender (on unit) : Female
Compatible devices : DVSe
CD-R, CD-RW
SCSI ID : 0
IEEE 1394 Firewire Port
The unit is equipped with an IEEE 1394 Firewire port
for connecting Firewire compatible external archive
devices. For information on the approved devices,
please refer to the Archiving Addendum manual that
is supplied with this unit.
Cable: 6 position Firewire
Connectors: 6 position DIP
RJ-45 socket on
back panel.
Caution! Ensure the power to DVMRe Triplex is OFF BEFORE connecting any SCSI or
1394 devices. Do not attempt to use the SCSI and 1394 ports simultaneously.
0150-0193G 14 DVMRe Triplex
RS232 Port 1
1
5
6
9
Slide approximately 6 inches of the power cord through the pre-installed
Loop the power cord end around and insert into the power receptacle on
For a Modem connection or remote control of unit. See section 3.17 for information about configuring
the modem settings in the menu system. See section 9 for RS232 Remote Control Protocols.
DB-9 Pin Configuration For Port 1
Pin Use
Pin Use
Pin Use
1 DCD 4 DTR 7 RTS
2 RX 5 Ground 8 CTS
3 TX 6 Not Connected 9 Not Connected
RS232 Port 2
For Event Generation and ASCII Text Insertion.
RJ-45 Pin Configuration For RS232 Port 2
Pin Use
1 Ground 5 TXD
2 Reserved 6 Not Connected
3 Not Connected 7 Ground
4 RXD 8 Reserved
Pin Use
1.8 Power-Up
Use the diagram below to secure the power cord to the back panel.
1
cable tie (approximately 1 inch after the ferrite core).
DB-9 on back panel.
82 3 4 5 6 71
RJ-45 socket on
back panel.
2
Tighten the cable tie until the cord is secure. Do not over tighten.
3
the back panel.
It is important that the power-up procedures be followed carefully. The unit uses its auto-detect
feature to detect camera signals during power-up, and configure itself automatically.
0150-0193G 15 DVMRe Triplex
1
2
3
Power-up procedure
Once the system installation is complete, apply
power in the following order:
Voltage: 12 Volt DC
1. Energize the monitors and all of the cameras.
Power: 60 Watt (5 Amp)
2. Energize the DVMRe Triplex.
Connector: 2.1mm barrel, center positive
Once power is applied to the unit, it will begin its power-up procedure. The unit will begin by displaying
the software version on Monitor-A, then the unit will begin recording automatically.
Power Supply Input
Check Video Input Quality
Check the picture quality by selecting each camera for full screen display. If the picture quality is poor,
check the following items:
• The BNC connections.
• The loop-through terminations.
• The video levels of incoming signals.
• The possibility of ground loops.
• Consult the camera’s installation instructions for additional information about proper camera setup.
Check Record And Playback Quality
Record for at least three minutes at the default record rate. Then play back the recording, selecting
each camera for full screen display. Check the playback picture quality.
1.9 Minimum Recommended Menu Setup
After installation is complete, it is strongly recommended that, as a minimum, the items in the
QuickInstall menu be configured before the unit is used. All the features located in the QuickInstall
menu are also found in the Main menu. These items are provided in the separate QuickInstall menu
as a convenience for the installer.
For information about accessing and configuring the menu system, see Section 3.
To find detailed information in this manual about configuring each item in the QuickInstall menu, use
the following table to locate the main menu location of each item in the QuickInstall menu.
QuickInstall
Menu Item
Change the time
Change the date
Edit Camera
Titles
Camera Disable
Record Quality
Main Menu → Time/Date → Set Time
Main Menu → Time/Date → Set Date
Main Menu → Camera Setup → Camera Titles → Edit Titles
Main Menu → Camera Setup → Camera Disable
Main Menu → Record → Record Quality
Main Menu Location
Section in
Manual
3.8
3.8
3.14
3.14
3.10
Installer
Password
Auto Disable
Now
0150-0193G 16 DVMRe Triplex
Main Menu → Passwords → Installer Password
Main Menu → Camera Setup → Camera Disable → Auto
Disable Now
3.20
3.14
2 DMVRe Triplex Basic Operations
2.1 Principal Operating Modes
The DVMRe Triplex has three principal modes of operation:
• Live Viewing.
• Playback.
• Recording.
All three of these modes can operate simultaneously. Each mode is discussed in detail later in this
section.
2.2 The Front Panel
1. Multiscreen Selection Buttons: 16, 10, 7, and 4 way.
2. Monitor Selection Button: Monitor A or Monitor B.
3. Multiscreen Selection Buttons: 13, 9, 6 way, and Picture-in-Picture.
4. Camera Selection Number buttons: Camera numbers 1 through 16.
5. Reverse Play Button: Playback in Reverse.
6. Freeze Button: Freezes camera images on-screen in Live mode. Pauses Playback.
7. Play Forward Button: Begins Playback.
8. Jog/Shuttle: Controls Playback speed and Menu selections.
9. Menu Button: Provides access to on-screen menus.
10. Power Indicator: Indicates power on/off condition.
11. Alarm button: Allows user to acknowledge and silence alarms.
12. Sequence Button: Sequences camera views.
13. Zoom Button: Provides a 2X digital zoom.
14. Function Button: Used in conjunction with Camera Buttons to run Macros.
15. Record Button: Used to Start and Stop Recording.
16. Stop Button: To stop Playback and return to Live mode.
17. Search Button: Access to stored video data.
18. Enter Button: Confirms selection in menus.
0150-0193G 17 DVMRe Triplex
2.3 Live Viewing
Multiscreen Display
In Live Multiscreen mode, press one of the Multiscreen buttons to activate
the multiscreen display on Monitor-A or Monitor-B. Live Multiscreens are
displayed with gray borders. For detailed information about Multiscreen
displays, see section 2.6.
Multiscreen Display With Sequencing
If a multiscreen display does not include all of the cameras, the remaining
cameras can be sequenced in the bottom right cameo. While in a multiscreen
display, press the Sequence button to begin sequencing. For detailed
information about sequencing, see section 2.8.
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of
the desired camera. Pressing the Camera number button again displays the
Status Display Box. Pressing the same button a third time displays any
associated ATM or cash register ASCII text, see section 2.9.
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full
screen sequencing. The sequence list and dwell times are programmable.
For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu
system, see section 0.
A
B
Multiscreen Buttons
Sequence Button
1
Number Button
Sequence Button
Zooming
To activate the 2x digital zoom, select the full screen display of the camera
you wish to zoom, then press the Zoom button. Zooming will be indicated by
the LED located directly above the Zoom button. Zooming is also indicated
as ZOOM on the primary monitor. Zooming works with frozen and non-frozen
images. Zoomed images can also be frozen.
While Zoomed, rotate the Jog/Shuttle to Pan and Tilt across the image.
Please note, the camera does not move during digital Pan/Tilt.
Press the Zoom button again to cancel the Zoom operations.
If the Zoom button is pressed while in a multiscreen display, the camera from the last active
NOTE
cameo is selected for full screen display. Press the Zoom button again to activate the Zoom
operation.
Freezing
Pressing the Freeze button freezes all camera images on-screen. Full
Screen freezing is indicated as FRZ on-screen. Multiscreen freezing is
indicated as * (a flashing asterisk) in each frozen cameo.
Individual cameos can be frozen in Active Cameo mode (see section 2.7).
Zoom Button
with LED
Freeze Button
Press the Freeze button again or any camera button to cancel Freeze
operations.
0150-0193G 18 DVMRe Triplex
Selecting Monitor-B
To control Monitor-B, press the lower part of the Monitor button. The
Monitor-B LED will light to indicate that the number keypad now controls
Monitor-B. Press the upper part of the Monitor button again to return the
keypad control to Monitor-A.
Monitor Button
A
B
2.4 Playback
Playback always displays on Monitor A. Playback multiscreen borders are black, as opposed to the
gray borders of the live multiscreens. Monitor B continues to display full or multiscreen live images in
playback mode. To begin playback, press the Play Forward or Reverse Play button.
Play Forward
When the Play Forward button is pressed, the unit will play forward at the rate
the data was recorded. While in Playback mode, the user may change the
playback direction, playback speed, etc. To return to Play Forward operations,
press the Play Forward button.
Reverse Play
To begin reverse playback, press the Reverse Play button.
Fast Forward
During playback, rotate the Shuttle (the outer dial) clockwise to view data at a
higher than normal rate. Increasing the amount of rotation increases the rate of
playback.
Play Forward
Button
Reverse Play
Button
Jog / Shuttle
AutoPause
During playback, moving the Jog (the inner dial) in any direction will freeze
playback. Depress the Freeze or any Play button to continue playback.
Rewind
During playback, rotate the Shuttle counter-clockwise to view data (in reverse) at
a higher than normal rate. Increasing the amount of rotation increases the rate of
playback.
Freeze
During playback, press the Freeze button. This feature pauses all full screen and
multiscreen images
Freeze Button
Single Frame Advance & Single Frame Rewind
During Freeze or Pause mode, rotate the Jog (the inner dial) to view the frame
directly before or after the frame displayed on-screen.
0150-0193G 19 DVMRe Triplex
Stop Playback
To stop playback and return to Live Multiscreen mode on Monitor A, press the
Stop button.
Multiscreen Display
During Playback, press one of the Multiscreen buttons to activate a
multiscreen display. The 6-way and PIP multiscreen displays are not
available in Playback mode. For detailed information about Multiscreen
displays, see section 2.6.
Multiscreen Display With Sequencing
If a multiscreen display does not include all of the cameras, the remaining
cameras can be sequenced in the bottom right cameo. While in a multiscreen
display, press the Sequence button to begin sequencing. For detailed
information about sequencing, see section 2.8.
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of
the desired camera. Pressing the Camera number button again displays the
Status Display Box. Pressing the same button a third time displays any
associated ATM or cash register ASCII text.
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full
screen sequencing. The sequence list and dwell times are programmable.
For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu
system, see section 0.
Zooming
To activate the 2x digital zoom, select the full screen display of the camera
you wish to zoom, then press the Zoom button. Zooming will be indicated by
the LED located directly above the Zoom button. Zooming is also indicated
as ZOOM on the monitor. Zooming works with frozen and non-frozen
images. Zoomed images can also be frozen.
While Zoomed, use the Jog/Shuttle to Pan and Tilt across the image.
Please note, the camera does not move during digital Pan/Tilt.
Stop Button
A
B
Multiscreen Buttons
Sequence Button
1
Number Button
Sequence Button
Zoom Button
with LED
Press the Zoom button again, or another camera button to cancel the Zoom
operations.
If the Zoom button is pressed while in a multiscreen display, the camera from the last active
cameo is selected for full screen display. Press the Zoom button again to activate the Zoom
operation.
Searching Recorded Data
The DVMRe Triplex has a powerful search interface feature that allows the user to search for data on
the internal hard disk or an external archive device. The user may search the data for previous
recording sessions, retail data, text insertion, alarm conditions, or for motion in a selectable area of the
0150-0193G 20 DVMRe Triplex
scene. Because the search interface is so dynamic, the search interface is covered in detail in a
Monitor A
Monitor B
separate section of this manual. See section 5.
2.5 Recording
To begin recording, press the Record button. Recording will be indicated by the
LED located directly above the Record button. The unit always starts recording
at the end of previously recorded data.
The unit will continue recording until the record button is pressed again.
Monitor Displays During Recording
Multiscreen Live and Playback displays on Monitor A and Monitor B are not affected by recording
operations.
Record Button
LIVE
PLAY
BACK
LIVE
LIVE
or
or
LIVE
LIVE
LIVE
PLAY
LIVE
BACK
0150-0193G 21 DVMRe Triplex
2.6 Display Options
Monitor A
Monitor B
Available Multiscreen Displays
Press the Multiscreen buttons to activate the multiscreen display. Pressing the individual multiscreen
button will display the corresponding multiscreen.
10-Way
7-Way
16-Way
4-Way
9-Way
6-Way
A
A
B
B
PIP
13-Way
The multiscreen display is limited to the number of camera inputs on the unit.
Sixteen-Channel unit: Capable of displaying all multiscreens.
Ten-Channel unit: Only capable of displaying 10-way through 4-way multiscreen and PIP.
Four-Channel unit: Only capable of displaying 4-way multiscreen and PIP.
The camera assignments for each multiscreen is retained (in non-volatile memory) for both Live and
Playback multiscreen mode on Monitor A, as well as Live multiscreen mode on Monitor B.
PIP: Use the Jog/Shuttle to adjust the location and size of the PIP display. Please note that the PIP
display is only available on Monitor A in Live mode, when Monitor B is in fullscreen display mode.
2.7 Active Cameos
A cameo is defined as any cell within a multiscreen display. Active Cameo mode allows the user to
access and edit each cameo individually.
Entering Active Cameo Mode
While viewing a multiscreen, enter Active Cameo mode by pressing the Enter
button. Active Cameo mode is indicated on-screen by flashing the number
and titles of the active cameo and the LED above the Enter button is lit. By
default, the top left cameo is activated.
Selecting Cameos
Select a cameo using the Jog/Shuttle to navigate the multiscreen. Rotating
the Jog selects the next screen up or down a row. Rotating the shuttle
selects the next screen in numerical order. The active cameo will always be
indicated by the flashing camera number and titles.
0150-0193G 22 DVMRe Triplex
Enter Button
Jog/Shuttle
Selecting Cameras
Display any camera in the active cameo by pressing the Number button of
the desired camera. Once a camera has been selected, the active cameo
advances to the next cameo on the right.
Number Button
The camera selection only changes the multiscreen currently being displayed. Each multiscreen must
be configured separately. Changes to the multiscreen display are saved in non-volatile memory, and
will be retained even if power is removed from the unit.
1
Freezing
Press the Freeze button to freeze the image in the selected cameo. Each
frozen cameo is indicated as * (a flashing asterisk) on-screen.
Press the Freeze button again to cancel Freeze operations.
Freeze Button
2.8 Sequencing
The sequencing feature allows a camera to be displayed briefly on-screen,
before advancing to the next camera in the sequence list. The default
sequence list displays each camera in numerical order.
Sequence Button
Dwell Time
The dwell time is the amount of time each camera is displayed on-screen before advancing to the next
camera. The Full Screen and Multiscreen Dwell Times are separately programmable in the menu
system. For detailed information about configuring the dwell times in the menu system, see section 0.
Autolist™ Custom Sequence List
The Autolist™ feature allows the user to create a custom sequence list, controlling the order the
cameras are displayed and the dwell time. Separate Autolists may be created for Monitor A (Live and
Playback mode) and Monitor B (Live mode). Using the Monitor button, select the monitor to be
programmed. Then, using a Number button, select any camera for full screen display.
The unit must be in Full Screen Display mode before starting to create the sequence list.
NOTE
To begin recording the Autolist™ sequence: Press the Alarm button and
Sequence button simultaneously. Autolist Program mode is indicated as
PGM on-screen.
Recording starts when the first camera number is pressed. Press the camera
numbers in the order you wish them to appear on-screen. The amount of
time between button presses determines the Dwell Time. During sequence
list programming, pressing any button other than a Number button or the
Sequence button voids the sequence list.
To end the recording: Press the Sequence button. The amount of time between pressing the last
Number button and the Sequence button determines the dwell time for the final camera in the
sequence list.
This initial camera is not part the sequence list.
Alarm Button and
Sequence Button
Returning To The Default Sequence List
The default sequence list is all cameras in numeric order with a three second dwell time.
0150-0193G 23 DVMRe Triplex
To return the unit to the default sequence list, go to the Main Menu → Sequencing → Full Screen
Dwell menu. Select 03 seconds by rotating the Jog, then press the Enter button.
Note: Any alteration of the dwell time from this menu will cancel the sequence list and return to the
default (numeric) order.
Sequencing In Cameos
While viewing a multiscreen display, additional cameras (cameras not shown in the multiscreen
display) can be sequenced in the lower right hand cameo by pressing the Sequence button. The
sequence list is not programmable, but the dwell time can be adjusted in the menu system. Press the
Sequence button again to cancel sequencing.
2.9 On-screen Indicators
There are five types of on-screen indicators.
Camera Titles: Displays the camera number and the camera title.
Status Indicators: Displays Time, Date, and Hard Disk record time left.
Conditional Indicators: Displays indicators for Freeze, Zoom, Alarm, Motion Detection, Videoloss,
Autolist™ Program mode, Macro Record and Macro Playback mode.
Status Display Box: Displays Archive Device, Network status and Image Quality Setting (Playback
mode only).
Text Display Box: Displays ATM/POS Text data.
Camera Titles
Camera Titles are displayed on either the upper or lower corner of the left hand side of the screen.
The camera title can be changed in the menu system (see section 3.14). The user can change display
position and color. See below.
Changing Position And Color Of Title And Status Indicators
Camera Titles: To change the color and position of the camera
titles, select a camera for full screen display, then press the Enter
button to advance to the next display setting. Repeatedly pressing
the Enter button advances the display settings through the
sequence show in the table on the right.
Example: Select Camera 1 for full screen display. Using the
Enter button, cycle through the sequence shown on the right.
Each time the position cycle is completed, the unit advances the
Status Indicator color. Choose Black, White or Gray.
Position Color
Top Left Black
Top Left White
Top Left Gray
Bottom Left Black
Bottom Left White
Bottom Left Gray
Title not displayed
Status Indicators
Status indicators are displayed on the upper right hand corner of the
screen.
Status indicators include:
• Time and Date (these can be turned off in the menu system, see
section 3.8). The Time and Date format can also be changed in
the menu system.
• Time remaining on Hard Disk(s).
0150-0193G 24 DVMRe Triplex
Small Cameo
Conditional Indicators
Condition Full Screen Indicator Multiscreen Indicator
Alarm
Autolist™ Program
mode
Freeze
Macro Record mode
Motion Detection
Videoloss
Zoom
F followed by macro number F followed by macro number
ALM A in cameo of camera in alarm
PGM PGM
FRZ
M M in cameo w/ motion detection
VDL V in cameo with videoloss
ZOOM ZOOM
(Asterisk) in frozen cameo
*
Status Display Box
A Status Display Box can be viewed by pressing the Camera Number button twice. Status Indicators
include:
On Live Fullscreen:
• Archive Status: Not Connected, Not Ready, Ready, Ejecting, Play, and timeleft. Timeleft
indicates the amount of time before the archive medium is full (Only available if the unit has
Background Archiving turned On).
• Network: Displays all current Network connections. Normal connection is displayed as ip.ip or ---
if there is no connection. Live connections are displayed as E1: ip.ip, E2: ip.ip, etc. (where ip.ip
represents the last 2 bytes of the IP Address). POTS connection is displayed as IP 1.1.
On Playback Fullscreen:
• All the above, including Image Quality Setting: High, Medium, Standard.
ATM/POS Text Display
Pressing the Camera Number a third time displays an ATM/POS text display. This feature can be
used during live viewing mode to verify that the DVMRe Triplex is receiving ATM/POS text, or in
Playback mode to review recorded text and video.
2.10 Triplex Mode
Triplex mode allows the display of both live and playback images to appear on Monitor A
simultaneously. Live images have gray borders, while playback images have black borders.
To enter Triplex mode, press the Play Forward button while in Play Forward mode. Alternatively, press
the Play Reverse button while in Play Reverse mode. Both the Play Forward LED and the Stop LED
turn on to indicate that the unit is in Triplex mode.
Monitor B always switches to a fullscreen live display whenever Triplex mode is entered.
Play Forward
When in Play Forward mode and the Play Forward button is pressed, the unit will
enter the Triplex mode of operation. When Play Forward is pressed again, the
unit will revert back into the normal Playback mode. While in the Triplex mode, if
reverse play is in progress, the Play Forward button will change the playback
direction.
Play Forward
Button
0150-0193G 25 DVMRe Triplex
Reverse Play
When in Reverse Play mode and the Reverse Play button is pressed, the unit will
enter the Triplex mode of operation. When Reverse Play is pressed again, the
unit will revert back into the normal Playback mode. While in the Triplex mode, if
forward play is in progress, the Reverse Play button will change the playback
direction.
Fast Forward
During Triplex mode, rotate the Shuttle (the outer dial) clockwise to view
playback images at a higher than normal rate. Increasing the amount of rotation
increases the rate of playback. Live images are not affected.
Rewind
During Triplex mode, rotate the Shuttle counter-clockwise to view playback
images (in reverse) at a higher than normal rate. Increasing the amount of
rotation increases the rate of playback. Live images are not affected.
Freeze
During Triplex mode, pressing the Freeze button pauses all multiscreen images,
both Live and Playback.
Single Frame Advance & Single Frame Rewind
During Freeze or Pause mode, rotate the Jog (the inner dial) to view the frame
directly before or after the frame displayed on-screen. Only the playback images
are affected.
Stop
To stop Triplex mode and return to Live mode on Monitor A, press the Stop
button.
Reverse Play
Button
Jog / Shuttle
Freeze Button
Stop Button
Multiscreen Display
During Triplex mode, press one of the Multiscreen buttons to activate a
multiscreen display. The 6-way and PIP multiscreen displays are not
available in Triplex mode. For detailed information about Multiscreen
displays, see section 2.6. The Live and Playback images in a multiscreen
display may be transposed by pressing the multiscreen button that
corresponds with the current multiscreen display.
E.g. If the current display is a 13-way multiscreen with the center cameo being a playback image and
the rest of the cameos being live images, pressing the 13-way multiscreen button will result in the
center cameo being live and the rest of the cameos being playback images.
0150-0193G 26 DVMRe Triplex
Multiscreen Buttons
A
B
Multiscreen Display With Sequencing
{F}
The bottom right cameo of any multiscreen will start sequencing when the
Sequence button is pressed. If this camera is a playback image, the
sequencing will include all the non-displayed playback cameras, and vice
versa for a live image.
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of
the desired camera. Pressing the Camera number button again displays the
Status Display Box. Pressing the same button a third time displays any
associated ATM or cash register ASCII text.
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full
screen sequencing. The sequence list and dwell times are programmable.
For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu
system, see section 0.
Zooming
To activate the 2x digital zoom, select the full screen display of the camera
you wish to zoom, then press the Zoom button. Zooming will be indicated by
the LED located directly above the Zoom button. Zooming is also indicated
as ZOOM on the monitor. Zooming works with frozen and non-frozen
images. Zoomed images can also be frozen.
While Zoomed, use the Jog/Shuttle to Pan and Tilt across the image.
Please note, the camera does not move during digital Pan/Tilt.
Sequence Button
1
Number Button
Sequence Button
Zoom Button
with LED
Press the Zoom button again, or another camera button to cancel the Zoom
operations.
NOTE
If the Zoom button is pressed while in a multiscreen display, the camera from the last active
cameo is selected for full screen display. Press the Zoom button again to activate the Zoom
operation.
2.11 The Print Image Feature
Pressing the Function and Zoom button will print the currently displayed
image. If any multiscreen is the display mode, the Triplex will switch to a
single image display of the last selected fullscreen camera, freeze the image,
and send to the default printer.
Zoom and Function
Button
0150-0193G 27 DVMRe Triplex
Printer Setup
The following equipment and conditions are required for the operation of the Print Image feature.
Equipment
HP DeskJet 3820
Hawking Print Server PN7127P
Conditions
The Printer and Print Server must be connected to the same local network as the Triplex.
The Triplex must be aware of the Print Server’s IP address. The IP address can be input under Main Menu – Communications – Ethernet – Ethernet Settings (See Section 3.15).
The Printer and Print Server must be On-line and Operational.
0150-0193G 28 DVMRe Triplex
3 Menu System Overview
3.1 Menu Notation In This Manual
In the following sections, there are headings like this:
q Main Menu → Time/Date → Set Time
Meaning: From the Main Menu, select Time/Date, then press the Enter button. The Time/Date menu
will appear. From the Time/Date menu, select Set Time, then press the Enter button. A pop-up or
pull-down menu will appear.
Selected Items
Items selected in the menu system are represented in the manual as follows:
Selected Not Selected
Time/Date Time/Date
3.2 Accessing The Menu System
Enter the menu system by pressing the Menu button. A Password Box will appear
on the primary monitor. Enter either the:
• Operator Password: Providing limited access to the menu system. Only the
Operator and System View menus are available.
Menu Button
• Installer Password: Providing complete menu access.
Use the Number buttons to enter the appropriate password.
Default passwords are provided in the beginning of this manual, in section 1.
3.3 Available Menus
MainQuickInstall
Time/Date
Sequencing
Record
Alarms
Macro
Motion Detection
Camera Setup
Archive Setup
Audio Setup
Communications
Front Panel Lock
Factory Settings
Passwords
Change the time
Change the date
Edit Camera Titles
Camera Disable
Record Quality
Installer Password
Auto Disable Now
Each menu is covered in detail in this chapter of this manual. Menus and Menu Items appear in the
manual in the same order they appear on-screen.
• Main Menu
• QuickInstall Menu
• Operator menu
• SystemView Menus
3.5 Navigating The Menu System
Selecting a Menu from the Menu Bar: When the menu system is first accessed, only the menu bar is displayed. Use the Shuttle to select the desired menu.
Opening the Drop Down Menus: Rotate the Jog.
Navigating in Menus: Rotate the Jog to highlight items in the drop-down menus.
Selecting Menu Items: Hit the ENTER button to select the highlighted menu item.
Exiting Menus: Press the Menu button to exit a menu. From the menu bar, press the Menu button
to exit the menu system completely.
Main
Time/Date
Sequencing
Record
Alarms
Macro
Motion Detection
Camera Setup
Archive Setup
Audio Setup
Communications
Front Panel Lock
Factory Settings
Passwords
Jog
OperatorSystemView
Jog
3.6 Menu Shortcuts
Zoom Button: In menu lists that have 2 settings per camera, the Zoom button will toggle all
selections. This provides a quick and easy way to enable or disable all cameras
for a particular feature.
0150-0193G 30 DVMRe Triplex
Camera Button: In menu lists that provide settings per camera, a particular camera may be
accessed directly by pressing on the associated camera button. Rotate the
Shuttle to modify the setting.
3.7 The Main Menu
Network Time Setup
Main Menu Overview
The Main menu contains the majority of programmable options for the DVMRe Triplex. Each item in the
Main menu is described in detail in this section of the manual.
Main menu items appear in this section in the same order they appear in the menu.
3.8 Time/Date
Use this menu to specify:
• Which monitors will display the time and date.
• The time format: 12 or 24 hours.
• The date format: MM/DD/YY, YY/MM/DD, or DD/MM/YY.
• The time and date.
• Whether the unit’s clock is a master or slave.
• Set Regional Daylight Savings Time.
• Setup clock synchronization between Triplex and Network Server.
Time/Date Display
Set Time Format
Set Date Format
Set Time
Set Date
Set Master/Slave
Set Region
q Main Menu → Time/Date → Time / Date Display
Use this menu to specify if the time and date will be displayed on:
• Monitor-A.
• Monitor-B.
• Both Monitors.
• Not Displayed
Rotate the Jog to navigate, then rotate the Shuttle to change the values.
Save changes and exit the menu: Select [OK], then press the Enter button.
Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press
the Enter button.
Time/Date Display
Monitor A :
Monitor B : ON
[CANCEL] [OK]
q Main Menu → Time/Date → Set Time Format
Rotate the Jog to set the desired time format. Select from either:
• 12 Hour
• 24 Hour
Press the Enter button to confirm the selection and exit the menu.
Time Format Setup
Select Format
12 HOUR
ON
Press the Menu button to exit the menu without making changes.
0150-0193G 31 DVMRe Triplex
Time Setup
[CANCEL] [OK]
Date Setup
[CANCEL] [OK]
Master/Slave Select
q Main Menu → Time/Date → Set Date Format
Rotate the Jog to set the desired date format. Select from either:
Date Format Setup
• MM/DD/YY
• DD/MM/YY
• YY/MM/DD
Press the Enter button to confirm the selection and exit the menu.
Press the Menu button to exit the menu without making changes.
q Main Menu → Time/Date → Set Time
1. Rotate the Shuttle to navigate, highlight HH MM SS.
2. Press the Enter button, the highlighting will move to the row of numbers.
3. Enter the time in Hours, Minutes, and Seconds. Rotate the Jog to
change the values and the Shuttle to navigate.
4. Press the Enter button to confirm the selection and exit the edit mode.
5. To save the changes and exit the menu: Rotate the Jog to select [OK],
then press the Enter button.
6. To exit the menu without making changes: Rotate the Jog to select
[CANCEL], then press the Enter button.
Select Format
MM/DD/YY
HH MM SS
03 05 53
q Main Menu → Time/Date → Set Date
1. Press the Enter button, the highlighting will move to the row of
numbers.
2. Enter the date in Months, Days, Years. The day of the week is
calculated automatically. Rotate the Jog to change the values
and the Shuttle to navigate.
3. Press the Enter button to confirm the selection and exit the edit mode.
4. To save the changes and exit the menu: Rotate the Jog to select [OK], then press the Enter
button.
5. To exit the menu without making changes: Rotate the Jog to select [CANCEL], then press the
Enter button.
MM DD YY Day
01 25 60 MON
q Main Menu → Time/Date → Set Master / Slave
If several multiplexers are installed and connected via RS485 network,
one of the multiplexers may be set as the master clock. This unit will
control the date and time (including daylight savings time) for all of the
other units.
Select One unit from the RS485 network as the master clock by selecting
YES in this menu. All other units must be set as NO (Default).
Master Clock
NO
0150-0193G 32 DVMRe Triplex
q Main Menu → Time/Date → Set Region
Use this menu to set the region for the Auto Daylight Savings Time
feature. Choices are:
• OFF: Clock will not be changed automatically, but can still
be adjusted by one hour using the daylight saving macros.
Regional Settings
Daylight Saving :
Time Zone :
USA
GMT+00:00
• USA: DST starts at 02:00 on the first Sunday in April.
Includes: United States (except Hawaii, American Samoa,
Guam, Puerto Rico, Virgin Islands, parts of Indiana and
Arizona) and Canada (except Saskatchewan).
[CANCEL] [OK]
• EUR: DST starts at 01:00 GMT on the last Sunday in
March. DST ends at 01:00 GMT on the last Sunday in
October. Includes: European Union Countries.
• AUS: DST starts at 02:00 on the last Sunday in October. DST ends at 03:00 on the last Sunday
in March. Includes: South Australia, Victoria, ACT, NSW. Excludes: Tasmania.
The Time Zone must be set correctly to ensure that the DST adjustments are made at the right time. It is
also required for accurate email time stamping.
The clock will only be automatically adjusted once on a given time and date. If you manually
NOTE
set the clock back before the last DST change, the time will not get automatically adjusted
again for that same time change.
q Main Menu → Time/Date → Network Time Setup
Use this menu to enable/disable and specify how often time synchronization should occur between the
Triplex and the Network Server. The Region /Time Zone must be setup prior to enabling the option.
Update Interval, Select from: Enable, Disable, Once per Day, Twice per Day, and Once per Hour
NTP Primary Server: Enter IP Address of Primary Server.
NTP Backup Server: Enter IP Address of Backup Server.
1. To save changes and exit the menu: Select [OK], then press the Enter button.
2. To exit the menu without making changes: Press the Menu button, or select [CANCEL], and then
press the Enter button.
Network Time Protocol Setup
Update Interval :
DISABLE
NTP Primary Server : 3. 37. 8. 26
NTP Backup Server : 0. 0. 0. 0
[CANCEL] [OK]
Last Update: Never Since Power-up
Warning: Region/Time Zone must be set correctly!
0150-0193G 33 DVMRe Triplex
3.9 Sequencing
Fullscreen Dwell
Record Quality
Event Settings
Use this menu to specify:
• The multiscreen dwell time.
• The full screen dwell time.
The dwell time is the amount of time each camera is displayed on-screen (while sequencing) before
advancing to the next camera.
q Main Menu → Sequencing → Multiscreen Dwell
Rotate the Jog to change the desired dwell time (from 1 to 30 seconds).
The default is 3 seconds.
1. Press the Enter button to confirm the selection and exit the menu.
2. Press the Menu button to exit the menu without making changes.
q Main Menu → Sequencing → Fullscreen Dwell
Rotate the Jog to change the desired dwell time (from 1 to 30 seconds).
The default is 3 seconds.
1. Press the Enter button to confirm the selection and exit the menu.
2. Press the Menu button to exit the menu without making changes.
Multiscreen Dwell
Fullscreen Dwell
Multiscreen Dwell
(Time in Seconds)
03
(Time in Seconds)
03
3.10 Record
Use this menu to:
• Specify the record quality: High, Medium, or Standard.
• Specify if a camera is to be used for event recording,
time-lapse recording, or both.
• Specify the time-lapse record rate per camera.
• Specify the event record rate per camera.
• Specify the activity record rate per camera.
• Specify the alarm record rate.
• Set the Record Lock feature.
• Perform disk maintenance by Deleting, Un-deleting, or
Destroying previously recorded video.
• Specify how the unit will handle data overwrite issues
once the hard disk becomes full.
Record Timer
Timelapse Record Rate
Event Record Rate
Activity Record Rate
Alarm Record Rate
Record Mode
Disk Maintenance
Record Lock
Auto Delete Mode
0150-0193G 34 DVMRe Triplex
q Main Menu → Record → Record Timer
Day Start Stop Macro ON/OFF
Record Quality
[CANCEL] [OK]
Use this menu to setup Preset Record Timer Events.
1. Rotate the Shuttle to select a timed event from the list.
2. Press the ENTER button to enter the Edit mode.
3. Rotate the Shuttle to navigate to the desired field.
4. Rotate the Jog to change the values of the selected field.
5. Press the Enter button to exit the Edit mode.
6. Rotate the Jog to highlight the [OK] field and press the
ENTER button to save the changes.
q Main Menu → Record → Record Quality
Use this menu to specify the record quality for each camera.
Decreasing the record quality decreases the amount of disk space
required to store the images, due to a higher compression
scheme.
Record Quality Picture Quality Disk Space Needed
High Excellent Most
Medium Good Medium
22:59 01:59 NONE ON
7
MON-FRI 05:56 04:06 10 ON
-- --:-- --:-- -- --
[OK]
Hit ‘ENTER’ to toggle EDIT Mode
Camera 01:
High
Camera 02: High
Camera 03: High
Camera 04: High
:
:
Standard Fair Least
Camera 16: High
3. Rotate the Jog to navigate, and the Shuttle to change the
values.
4. To save changes and exit the menu: Select [OK], then press
the Enter button.
5. Exit the menu without making changes: Press the Menu button, or select [CANCEL], and then
press the Enter button.
q Main Menu → Record → Event Settings
Use this menu to specify how each camera will record during normal
and event conditions.
TL: Records at the Time-lapse Record Rate under normal conditions.
Does not change record rate during an event.
Event: Records during events at the Event Record Rate. Camera
does not record under normal conditions.
Event + TL: Records at the Time-lapse Record Rate under normal
conditions. Records at the Event Record Rate during events.
Camera :
Type : Event + TL
Pre Event Duration : 00
Post Event Duration : 000
Event Associated Cameras: -- -- --
Event Camera Settings
[CANCEL] [OK]
01
0150-0193G 35 DVMRe Triplex
About Events: An Event is an action that the unit acknowledges by recording at the
NOTE
Event Record Rate, yet it is not cause for an Alarm. Events may be created two ways,
via RS232 text insertion and Activity detection.
Example of an Event: A camera is pointed at the front door inside the lobby during
business hours. With the Event Camera Settings Type set to Event, the unit does not
record while the doorway is empty. When activity motion detection senses that
someone is entering or leaving the doorway, the unit begins recording at the Event
Record Rate and stops recording when the motion ceases.
RS232 Event: See section 9 for information about generating an Event via RS232, and
optionally inserting ASCII text to mark the Event.
Activity Detection Event: See Setup Parameters in section 3.13 for detailed
information about configuring activity detection as an event in the menu system.
Pre Event Duration: The unit will record up to 5 seconds of data ahead of the event trigger, at the
Event Record Rate. Select from 0 to 5 seconds.
Post Event Duration: The unit will record up to 250 seconds after the completion of the Event, at the
Event Record Rate. Select from 0 to 250 seconds.
Event Associated Cameras: Enter up to three camera numbers to be associated with this event.
q Main Menu → Record → Timelapse Record Rate
The unit records at the Timelapse Record Rate under normal conditions, when there are no alarms,
events, or activity present. Record rates are measured in both Pictures Per Second (pps) and Seconds
Per Picture (spp).
The maximum record rate per camera is inversely proportional to the number of cameras connected to
the unit. The fewer cameras connected, the higher the maximum record rate for each camera, and vice
versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum
record rate for a single camera is 30pps (NTSC)(25pps PAL).
The bottom right corner of the menu contains a record duration calculator. The top line indicates the
estimated recording time for the unit in Time-lapse record mode only. The bottom line indicates the
estimated recording time, taking into consideration the amount of time the unit will spend in Activity,
Event, and/or Alarm record mode.
Timelapse Record Rate
Camera 1 :
Camera 2 : 0.29 pps 3.5 spp
Camera 3 : 0.34 pps 2.9 spp
Camera 4 : 0.57 pps 1.8 spp
:
:
:
Camera 15 : 0.40 pps 2.5 spp
Camera 16 : 0.40 pps 2.5 spp
0.40 pps 2.5 spp
[CANCEL] [OK]
8 days 5 h (TL)
8 days 5 h (Total)
0150-0193G 36 DVMRe Triplex
1. Rotate the Jog to navigate, and the Shuttle to change the values.
Estimate of the % of time each
camera will typically spend in
Event mode. For example if you
events each day, each lasting 3
minutes on average, then the %
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then
press the Enter button.
q Main Menu → Record → Event Record Rate
The unit will record at the Event Record Rate when an Event is activated. Events can be activated by
RS232 event generation or activity detection. See Event Settings on page 35.
Record rates are measured in both Pictures Per Second (pps) and Seconds Per Picture (spp).
The maximum record rate per camera is inversely proportional to the number of cameras connected to
the unit. The fewer cameras connected, the higher the maximum record rate for each camera, and vice
versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum
record rate for a single camera is 30pps (NTSC)(25pps PAL).
The bottom right corner of the menu contains a record duration calculator. The top line indicates the
estimated recording time of the cameras in Event record mode only. The bottom line indicates the
estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse,
Activity, Event, and/or Alarm record mode.
Event Record Rate
Camera 1 :
Camera 2 : 0.29 pps 3.5 spp
Camera 3 : 0.34 pps 2.9 spp
Camera 4 : 0.57 pps 1.8 spp
:
:
:
Camera 15 : 0.40 pps 2.5 spp
Camera 16 : 0.40 pps 2.5 spp
0.40 pps 2.5 spp
[CANCEL] [OK]
% Time: 4%
% Time: 4%
125 days 8 h (EVENT)
10 days 7 h (Total)
expect to have about 20 total
of the time will be
(1 hour/24 hours)
4%.
1. Rotate the Jog to navigate, and the Shuttle to change the values.
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then
press the Enter button.
q Main Menu → Record → Activity Record Rate
The unit will record at the Activity Record Rate when the camera is in normal Timelapse Record Mode
and activity is detected in the camera scene. Activity should not be linked to Event, in which case the
Event Record Rate will be used.
Record rates are measured in both Pictures Per Second (pps) and Seconds Per Picture (spp).
The maximum record rate per camera is inversely proportional to the number of cameras connected to
the unit. The fewer cameras connected, the higher the maximum record rate for each camera, and vice
0150-0193G 37 DVMRe Triplex
versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum
total periods of activity each day,
each lasting 3 minutes on average,
each lasting 3 minutes on average,
record rate for a single camera is 30pps (NTSC)(25pps PAL).
The bottom right corner of the menu contains a record duration calculator. The top line indicates the
estimated recording time of the cameras in Activity record mode only. The bottom line indicates the
estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse,
Activity, Event, and/or Alarm record mode.
Activity Record Rate
Camera 1 :
Camera 2 : 0.29 pps 3.5 spp
Camera 3 : 0.34 pps 2.9 spp
Camera 4 : 0.57 pps 1.8 spp
:
:
:
Camera 15 : 0.40 pps 2.5 spp
Camera 16 : 0.40 pps 2.5 spp
0.40 pps 2.5 spp
[CANCEL] [OK]
% Time: 4%
% Time: 4%
68 days 11 h (ACTIVITY)
9 days 16 h (Total)
Estimate of the % of time each
camera will typically spend in
periods of activity. For example
if you expect to have about 20
then the % of the time will be 4%.
(1 hour/24 hours)
1. Rotate the Jog to navigate, and the Shuttle to change the values.
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then
press the Enter button.
q Main Menu → Record → Alarm Record Rate
During an alarm, the unit records at the alarm record rate. The bottom of the menu contains a record
duration calculator. The top line indicates the estimated recording time of the cameras in Alarm record
mode only. The bottom line indicates the estimated recording time, taking into consideration the amount
of time the unit will spend in Time-lapse, Activity, Event, and/or Alarm record mode.
The configuration of the Alarm Record Rate is closely associated with the Alarm Record Mode. For
detailed information about configuring the Alarm Record Mode, see Alarm Record mode in section 3.11.
1. Rotate the Jog to navigate, and the Shuttle to change the values.
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then
press the Enter button.
0150-0193G 38 DVMRe Triplex
Global Alarm Record Rate
% Time:
1%
60 pps
40 days 20 h (Alarm)
15 days 11 h (Total)
[CANCEL] [OK]
Estimate of the % of time the
unit will typically spend in
alarm mode. For example
if you expect to have about 5
total periods of alarms each day,
then the % of the time will be 1%.
(15 min/24 hours)
Record
Duration
Calculator
No overwrite
q Main Menu → Record → Record Mode
Use this menu to specify how the unit will handle data overwrite
issues once the hard disk becomes full.
Write once
Continuous
No Overwrite:
• Recording starts at the end of the last recording.
• Recording stops when disk becomes full.
• When the hard disk becomes full, the unit displays an on-screen message indicating that the
device is full and that the archive device has stopped recording. The user must acknowledge the
message by pressing the Enter button.
Write Once:
• Recording starts at the end of the last recording.
• Recording stops when disk becomes full.
• The user is prompted to authorize overwriting old data.
Continuous:
• Recording starts at the end of the last recording.
• Unit overwrites all previously recorded data, overwriting the oldest data first.
• The unit does not stop recording when disk becomes full.
q Main Menu → Record → Disk Maintenance
Use the Jog to select from the following options, then press the
Enter button to begin.
Delete: Delete all data from the hard disk (with the possibility of restoring it).
Undelete: Restore data that has been deleted, but not yet overwritten.
Destroy: Erase all data from the hard disk permanently, without the possibility
of restoring it. Selecting this option brings up a confirmation dialog box.
Test: Provides access to the Disk Test Setup menu which features disk test and
monitoring options.
Delete
UnDelete
Destroy
Test
Disk Test Setup Menu
The Disk Test Setup menu provides several testing options including the test time, frequency, and
duration.
Disk Test: Options include Disable, Test Now, Test Periodically. The Test Periodically option runs
the Disk Test at the specified frequency. The Disk Tests run in the background and will not interfere
with normal operations.
Test Frequency in hours: From 0 to 1000 hours between tests.
Test Duration: This option is for the type of test to run; Fast or Thorough. The Thorough test will
test significantly more sectors than the Fast test. GE recommends using the Thorough test. The Fast
test can miss some disk failures
0150-0193G 39 DVMRe Triplex
Disk Test Setup
Disk Test Result
Disk 1:Write Error
Disk 2:Write Error
PASSED
FAILED
OFF
Disk Test:
Test Frequency in hours: 0
Test Duration: Fast
[CANCEL] [OK]
Disk Test Result: Disk Failed
Disk 1: Write Error
Disk 2: Write Error
DISABLE
Use the Jog to move between the menu fields and the Shuttle for the selections within the fields.
When satisfied with the selections select OK and press the Enter button to execute.
The Disk Test will run in the background and will not interfere with normal operations. Once the disk
test is done, a message will appear on the screen indicating the test result.
Disk Test Result
Disk Failure
Disk Test Success
[OK][OK]
Press the Enter button to clear from the display.
Should a disk test fail, several actions will performed:
• An icon will be displayed indicating disk failure. It is displayed on Monitor A on the bottom of the
screen in the middle. This icon will only disappear when the disk is replaced.
• If the alarm or record email option is enabled in the Email Notification Setup Screen, an email will
be sent indicating that a disk failure occurred.
q Main Menu → Record → Record Lock
Use this menu to set the Record Lock feature. This feature disables the front panel
record button. Setting Record Lock to ON will start the unit recording if it is not currently
in the Record mode.
ON
0150-0193G 40 DVMRe Triplex
q Main Menu → Record → Auto Delete Mode
Yes
Alarm Action
Relay Configuration
Input Configuration
The ADM feature prevents the unit from displaying or archiving any search results that are more than
thirty days old. This feature may be required by law in some jurisdictions. Choose from 1 to 99 days or
Off. The default setting is Off.
ADM Setting
Message
ADM will change. Are you sure?
99 Days
3.11 Alarms
Use this menu to configure the alarm handling features of the unit.
Caution! The DVMRe Triplex’s primary function is to furnish
video multiplexing and recording with a multiscreen display.
Although the unit has alarm handling and motion detection
functions, these are considered secondary features. This unit should not be the only alarm device on site.
q Main Menu → Alarms → Input Configuration
Configure the alarm inputs as either Normally Open or Normally Closed.
Alarm Latch
Alarm Record Mode
Enable / Disable
Alarm History
Link to a Macro
Fullscreen Alarm
Buzzer Setup
Videoloss Action
Pre Alarm Duration
Notification
Archive Alarms
Configure inputs as follows.
Normally Open Zero Potential Relay Contact: Configure in menu as
Normally Open.
Normally Closed Zero Potential Relay Contact: Configure in menu
as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
TTL Active Low: Configure in menu as Normally Open.
Open Collector Active On: Configure in menu as Normally Open.
Open Collector Active Off: Configure in menu as Normally Closed.
0150-0193G 41 DVMRe Triplex
q Main Menu → Alarms → Alarm Latch
Alarm Action Setup
Input :
This feature determines how the unit latches alarm conditions.
Select from the following options:
Latched: The alarm is activated until it is silenced and acknowledged
Latched
Transparent
Timed Out
by the user.
Transparent: The alarm is active only while receiving alarm input.
The alarm condition is canceled when the alarm input ceases.
Timed Out: The alarm condition is latched for the amount of time selected in this menu, then it is
automatically silenced and acknowledged. If the alarm input exceeds the duration specified in this
menu, the unit silences and acknowledges the alarm when the alarm input ceases. Select the timeout
duration, the range is from 1 to 250 seconds.
Transparent alarms cannot be silenced and acknowledged. If transparent mode is preferred, but the
ability to silence and acknowledge alarms is desired, select Timed Out and set the Alarm Timeout to
two seconds.
q Main Menu → Alarms → Alarm Action
This menu is not available on 4-channel units. Only the full
screen alarm display is available on the 4-channel unit.
Therefore, a 4 channel unit will always be limited to the default
values in this menu, i.e. no presets linked to alarms and alarm
relay is always Relay 1.
Input: Select the input you wish to configure.
Freeze: Selecting Yes will freeze the alarm camera display
Cameras: This setting determines the four cameras displayed
[CANCEL] [OK]
on-screen when an alarm is received. The camera group contains
the camera in alarm and three associated cameras.
Default Settings: The first camera in the list is the camera in alarm.
The second camera in the list is the camera that precedes the alarm camera numerically. The third
and fourth cameras in the list are the two cameras following the alarm camera numerically.
Preset: Use this feature to send a camera to a preset when an alarm is activated. The preset number
corresponds directly with the camera number located directly above it in this menu. Select from 1
through 16. If this field is left blank, the camera will not respond. In the example above, Camera 1 will
go to Preset 1, while Camera 2 will go to Preset 9.
Relay: Configure which relay will be triggered when an alarm is activated per camera. Select from:
• 1
• 2
• 1 + 2
• None
Intrusion AND/OR: Use this feature to activate alarms by hardwired alarm inputs AND/OR Intrusion
detection. Select from AND or OR. Motion Detection must be set to Intrusion and linked to the Alarm
number.
Rotate the Jog to navigate and the Shuttle to change the values.
0150-0193G 42 DVMRe Triplex
q Main Menu → Alarms → Alarm Record Mode
Alarm Record Mode
Use this menu to determine how the unit will record cameras in alarm.
No Change: Unit changes to the Alarm Record Rate, but it does not
give priority to the camera in alarm.
Select Mode
Interleaved
Exclusive: The unit records only the camera (or cameras) in alarm.
Interleaved: Alarmed cameras are recorded at a higher rate than
non-alarm cameras. The unit accomplishes this by interleaving images
of alarmed cameras between images from non-alarmed cameras in the record list. Interleaved is the
recommended mode of operation.
Example of Record Lists:
No Change record list for 8 cameras, Camera-4 in alarm. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Exclusive record list for 8 cameras, Camera-4 in alarm. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Interleaved record list for 8 cameras, Camera-4 in alarm. 1 4 2 4 3 4 5 4 6 4 7 4 8 4 1 4
q Main Menu → Alarms → Enable / Disable
Use this menu to Enable or Disable the alarm inputs.
Select from the following:
• Individual Enable: Allow the user to access the Alarm
Enable submenu, and enable or disable alarm inputs on
a per camera basis.
• Enable All
• Disable All
Rotate the Jog to navigate, and the Shuttle to change
the values.
Save changes and exit the menu: Select [OK], then press the
Enter button.
Exit the menu without making changes: Press the Menu
button, or select [CANCEL], then press the Enter button.
q Main Menu → Alarms → Alarm History
Use this window to view a list of the 100 most recent alarms.
Alarms are displayed 10 at a time. Rotate the Jog to scroll
through the alarms.
Information displayed in this window is:
• The alarms number in the list.
• The date of the alarm (month and day).
• The time of the alarm (hours, minutes, and seconds).
Use this menu to link an alarm input to a macro. If a link is created,
a macro will run each time that alarm is activated.
Alarm: Select the alarm input you would like to link.
Macro: Select the macro number you wish to link to. Leave this
setting blank if you do not wish to link to a macro.
Rotate the Jog to navigate, and the Shuttle to change
the values.
Save changes and exit the menu: Select [OK], then press the
Enter button.
Exit the menu without making changes: Press the Menu
button, or select [CANCEL], then press the Enter button.
q Main Menu → Alarms → Fullscreen Alarm
Selecting Yes from this menu will cause the unit to always display
the alarm camera fullscreen.
Selecting No from this menu will cause the unit to display the 4-way
display configured in the Main Menu → Alarms → Alarm Action
Setup menu.
Fullscreen
NO
This menu selection is not available on 4-channel DVMRe Triplex units, since Fullscreen Alarm Mode is
the only alarm mode available.
q Main Menu → Alarms → Relay Configuration
Relay Configuration
Use this menu to configure each relay output as either:
• Normally Open
• Normally Closed
Relay 01:
Relay 02: N/CLOSED
[CANCEL] [OK]
N/OPEN
q Main Menu → Alarms → Buzzer Setup
Use this menu to configure the internal buzzer.
Global Buzzer: The Global Buzzer setting acts as a master On/Off
switch. Setting the Global Buzzer to OFF deactivates all buzzer
activity.
Live Alarm Buzzer: Activates while receiving alarm input.
Videoloss Buzzer: Activates when video loss is detected.
Disabling the Videoloss buzzer disables all videoloss buzzer activity.
Videoloss buzzers may be disabled on a per camera basis in the
Alarms → Videoloss Action menu.
Global Buzzer :
Live Alarm Buzzer: ON
Videoloss Buzzer : ON
Playback Buzzer : ON
ON
Playback Buzzer: Activates during playback of recorded alarms.
0150-0193G 44 DVMRe Triplex
q Main Menu → Alarms → Videoloss Action
Videoloss Action
Relay 1: Disable
Buzzer : Enable
Pre Alarm Duration
Use this menu to configure how the unit responds to videoloss.
Camera: Select the camera you wish to configure.
Relay 1: If enabled, the unit will activate Relay 1 when videoloss
is detected.
Relay 2: If enabled, the unit will activate Relay 2 when videoloss is
detected.
Buzzer: Use this setting to disable the videoloss buzzer activation
on a per camera basis. To disable videoloss buzzer activation on
all cameras go to the Main Menu → Alarms → Buzzer Setup menu,
described in the previous section.
q Main Menu → Alarms → Pre Alarm Duration
During recording, the unit stores up to 5 seconds of recorded
information in a buffer. This data can be automatically retrieved when
an alarm is activated. Select the amount of time just previous to the
activation of an alarm you wish to retrieve.
Camera :
Relay 2: Enable
[CANCEL] [OK]
(Time in Seconds)
01
05
q Main Menu → Alarms → Notification
Use this menu to select:
• Email Alarm Notification.
• TCP/IP Notification.
Email
TCP/IP
Email Notification Setup
This screen allows the user to setup the types of events to be notified of, and the email addresses (up
to two) to be notified. Follow the context sensitive on-screen instructions to setup the individual fields.
Also, please note that the Region/Time Zone setting must be set correctly for Email notification to time
stamp messages accurately.
0150-0193G 45 DVMRe Triplex
Email Notification Setup
One or more of these
fields must be set to
ENABLE to receive an
email notification of
the selected event.
Obtain the parameters
for these two fields from
your IT Department.
Notify Vidloss:
Notify Alarm:
Notify Record:
Notify Archive:
Notify Menu Access:
Notify Power Up:
Notify Connection:
Email User 1:
Email Domain 1:
Email User 2:
Email Domain 2:
SMTP Server:
SMTP Port:
Format of email address: user@domain
Warning: Region/Time Zone must be set correctly!
Only if Notify Alarm is set to enable will the email include a link to the video on the disk.
The link pertains only to the alarm start. For more information see section 6.2.
Email Address Format
The format of the email addresses should be entered as follows. If the email address to be notified is
john.doe@somecompany.com, then john.doe should be entered in one of the Email User fields and
somecompany.com should be entered in the subsequent Email Domain field.
TCP/IP Notification Setup
This screen allows the user to setup the types of events to be notified of, and the IP addresses (up to
two) of the PC(s) where the WaveReader software resides.
WaveReader must be running on the receiving PC(s) and Alarm Monitoring must be setup. See Alarm
Monitoring in the WaveReader Manual for details.
The Notification Interval can be set from 1 minute to 60 minutes, or immediately upon the event.
q Main Menu → Alarms → Archive Alarms
Selecting Enable from this menu will cause the unit to activate
Relay 2 if a malfunction occurs while archiving.
Archive Alarm
Relay 2
ENABLE
3.12 Macro
A macro is a recorded sequence of keystrokes. The number of macros depends on the number of
camera inputs (4, 10 or 16). Each macro can have up to 32 keystrokes.
Use this menu to:
• Enter Macro Record mode.
• Program a scheduled start time for a macro.
• Edit the RS232 command string for each submacro.
q Main Menu → Macro → Macro Record
Note: Do not attempt macro programming while the front panel is locked.
To begin recording a macro:
1. Select the macro number you wish to record, then press the
Enter button. The unit will automatically exit the menu
system and go to a starting point. Macro Record mode
is indicated as F and the Macro Number on-screen.
2. From this point, begin recording the desired keystroke sequence. Record up to 32 keystrokes. If
32 keystrokes are exceeded, the unit will end the macro recording automatically.
3. When finished programming, press the Function button then the Enter button to end the macro
recording. A form is provided in section 10 to keep track of recorded macro functions.
Macro Record
Timed Macro Start
Edit Submacro
01
0150-0193G 47 DVMRe Triplex
Keystroke count while in the menu system: While recording a macro, entering the
NOTE
During macro recording, the following button combinations perform special functions.
Button Sequence Resulting Action
menu system, changing multiple menu items, and exiting the menu system are only
counted as one keystroke. Using the Jog to navigate the menu system does not count
as keystrokes. Once the menu system has been exited, re-entering the menu system
will count as a second keystroke.
Not all menu items can be programmed using macros. For a complete list of macro
programmable menu items, see the table below.
Function then 1.
Function then 2.
Function then 3.
Function then 4.
Function then 5.
Function then 6.
Function, Function, then
Submacro number.
Function then Enter.
Activate Relay 1 output.
Reset Relay 1 output.
Pause macro for 1 second.
Pause macro for 5 seconds.
Activate Relay 2 output.
Reset Relay 2 output.
Program a specific submacro to activate when the macro is run.
End macro recording
Macro Excluded Features
The following core features or settings cannot be programmed by Macro.
• Disk Maintenance.
• Erase Archive Medium.
• POTS Setting.
• Ethernet Setting.
• RS485 Network Address.
• Front Panel Lock/Unlock.
• Record Timer.
q Main Menu → Macro → Timed Macro Start
Use this menu to program scheduled start times for macros. Up
to 20-scheduled start times can be programmed in this menu.
Event: Select the scheduled start event you wish to edit.
Day: Select the start day (Monday – Sunday) of the macro.
Select ** (double asterisks) to run the macro every day.
Select None to cancel the scheduled start time.
Time: Select the start time for the macro.
Macro: Select the desired macro number.
A form is provided in section 10 to keep track of scheduled macros.
0150-0193G 48 DVMRe Triplex
Timed Macro Setup
Event :
Day : Monday
Time : 00:00
Macro : 01
[CANCEL] [OK]
01
Setup Parameters
Setup Active Zones
Indicate Detection
q Main Menu → Macro → Edit Submacro
A submacro is an RS232 command string that is used to control a peripheral device. Submacros are
activated during macros. See the table above for information about programming a macro to activate
a submacro.
Select the submacro you wish to edit from the menu system. This menu will appear.
Edit Submacro 01
080 066 066 010 --- --- --- --- --- ---
[P] [B] [B] [0]
[CANCEL] [OK]
ENTER key starts Submacro edit
Use this menu to create the RS232 command string. Press the Enter button to Enter and Exit the
submacro edit mode. Rotate the Jog/Shuttle to navigate among the fields and change the values.
Each byte value can be set from 0 to 255.
Running A Macro
A macro is a recorded sequence of up to 32 keystrokes. To activate a
macro, press the Function button followed by the Number button of the
desired macro. While running, the macro is indicated on-screen as the letter
F and the macro number.
The user can cancel the macro at any time by pressing the Function button.
{F}
Function and
Number Buttons
Daylight Savings Time (Alternate Method)
To adjust the time one hour for daylight savings time, press the Function
button, then the Sequence button. If this function is activated during April,
one hour is added to the time. If this function is activated in October, one
hour is subtracted from the time. This function will only operate once per
time period.
{F}
Function and
Sequence Buttons
1
3.13 Motion Detection
Use this menu to:
• Enable motion detection on a per camera basis.
• Activate individual zones in a scene to respond to motion
• Activate the on-screen motion detection indicator.
• Set motion detection as Activity detection or Intrusion Detection.
• Configure the motion detection parameters on a per camera basis.
0150-0193G 49 DVMRe Triplex
Enable/Disable Detection
detection.
q Main Menu → Motion Detection → Enable/Disable Detection
Detection Enable
Camera 02: Disable
Selecting Enable All or Disable All from this menu will activate or deactivate
motion detection on all cameras.
Selecting Individual Enable from this menu will bring up the following menu.
Individual Enable
Enable All
Disable All
Individual Enable Menu
Use this menu to enable or disable motion detection on a per
camera basis. Rotate the Jog to navigate, and the Shuttle
Camera 01:
Enable
to change the values.
Camera 03: Enable
:
:
Camera 16: Enable
[CANCEL] [OK]
q Main Menu → Motion Detection → Setup Parameters
Use this menu to select the Camera, Motion Detection Type, and Sensitivity of the Motion Detection
you wish to configure.
Motion Detection Parameters Setup
Camera
Motion Detection Type
Sensitivity
Relay Output
Link to Event
Rejection
Target Size
Link to Alarm
[CANCEL] [OK]
01
ACTIVITY
06
2
---
LOW
01
NONE
Navigate in this menu using the Jog to select the field and the Shuttle to change the parameters.
Activity Vs. Intrusion
Activity Detection is a simple type of motion detection having only a sensitivity setting and a relay
output. Intrusion Detection is a more sophisticated type of motion detection, with additional features
such as false alarm rejection levels, minimum target size, and an alarm output.
0150-0193G 50 DVMRe Triplex
Activity Detection Setup
If Activity is selected in Motion Detection Type field, the following parameters are enabled:
Relay Output: The unit may be configured to activate a relay output when motion detection is
present. Select either 1, 2, 1+2 (both relays), or None.
Link to Event: Selecting Yes in this menu will activate the event record speed when activity detection
is present.
Intrusion Detection Setup
If Intrusion is selected in Motion Detection Type field, the following parameters are enabled:
Sensitivity: Rotate the Shuttle to change the motion detection sensitivity, 10 being the most
sensitive.
Rejection: Configure the unit’s false alarm rejection feature by selecting Low, Medium, or High.
These settings are based on the number of simultaneously triggered zones and the persistence of
motion in a scene. The Low setting is the most sensitive to motion. The Medium setting will filter out
most false alarm situations due to sudden luminance changes over the whole scene (clouds passing
over). The High setting will filter out sudden luminance changes as well as spurious motion events
that do not persist for a number of frames (a bird flying past the lens).
Target Size: This setting is the minimum number of zones (from the 16 x 16 grid) that must be
activated simultaneously before it is considered to be valid motion.
Link To Alarm: Select the alarm number that you wish to activate when motion detection is activated.
q Main Menu → Motion Detection → Setup Active Zones
Use this menu to setup the Active Zones for motion detection. The screen shown below will overlay the
current video image allowing for precise activity zone setup. The disabled zones will be tinted. The
enabled zones will be clear.
Activity Grid Setup Screen
5
Pressing the Function button will bring up the Help screen shown on the next page. This screen will
overlay the current video image.
0150-0193G 51 DVMRe Triplex
‘MENU’ : Exit Activity Setup
‘ENTER’: Save and Exit Activity Setup
‘PAUSE’: Toggle between Enable and Neutral
‘STOP’ : Toggle between Disable and Neutral
‘PLAY FORWARD’: Increase the Sensitivity level
“PLAY REVERSE’: Decrease the Sensitivity level
{F}
Play Forward to increase the Sensitivity
Indicate Detection
Titles Display
Function
‘ZOOM’ : Disable/Enable all zones
Button
Sensitivity Scope
Use the sensitivity scope to adjust the motion detection sensitivity for the scene. The
sensitivity scope is the bar located near the left-hand corner of the screen.
The black bar raises and lowers to indicate the degree of motion detected. When the
black bar reaches the red bar, a motion detection alarm is activated.
Adjusting Motion Detection Sensitivity: Raise and lower the red bar to change the
motion detection sensitivity. Use the Play Forward button to increase the sensitivity level
and the Play Reverse button to decrease the sensitivity level. The sensitivity level is also
displayed as a numeric value.
Play Reverse to decrease the Sensitivity
q Main Menu → Motion Detection → Indicate Detection
Motion Detection may be indicated on-screen by displaying the letter M.
Use this menu to turn this feature On or Off.
Detection
ON
3.14 Camera Setup
Use this menu to:
• Edit the title for each camera.
• Adjust the Automatic Gain Control.
• Disable or Enable camera inputs.
• Specify cameras as covert (recorded but not displayed).
• View the Camera Scope (Histogram)
• Enable or Disable SVHS output on Monitor B.
q Main Menu → Camera Setup → Camera Titles
Use this menu to:
• Specify if the camera titles will be displayed on the monitors.
Edit the title for each camera.
0150-0193G 52 DVMRe Triplex
Edit Titles
Titles Display
Titles Display
[CANCEL] [OK]
Monitor B: OFF
Camera titles may be displayed on either monitor. Use this menu
to turn this feature On or Off.
Rotate the Jog buttons to navigate and the Shuttle to change the values.
Monitor A:
Edit Titles
Rotate the Shuttle to select the camera whose title you wish to configure, and then press the Enter
button. The Camera Title Edit menu will appear.
Camera Title Edit
ON
Camera
Title : Camera 01
@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^
SEQ key selects character bank
‘1’ key inserts blank character
‘2’ key inserts selected character
1
[CANCEL] [OK]
Camera Title Edit Menu
1. With the camera title selected, press the Enter button. The menu will enter the Edit mode and the
character bank will appear in the center of the menu.
2. Press the Sequence button to select the desired character set.
3. Rotate the Shuttle to navigate the cursor in the camera title.
4. Rotate the Jog to navigate the cursor in the character bank.
5. Press the Number 1 button to insert a blank character or press the Number 2 button to insert the selected character.
6. When finished editing the title, press the Enter button to exit the edit mode.
7. Save changes and exit the menu: Select [OK], then press the Enter button.
8. Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu → Camera Setup → AGC
Use the Automatic Gain Control (AGC) to adjust the video input
signal level for cameras whose level is outside the normal range.
The default gain setting is 100%.
Rotate the Jog to navigate and the Shuttle to change the values.
Signal Gain Setup
Camera 01
Signal Gain 100%
Save changes and exit the menu: Select [OK], then press the
Enter button.
[CANCEL] [OK]
Exit the menu without making changes: Press the Menu button,
or select [CANCEL], then press the Enter button.
0150-0193G 53 DVMRe Triplex
Main Menu → Camera Setup → Camera Disable
Power Up Disable
Auto Disable Now
Individual Disable
Camera Disable
[CANCEL] [OK]
Camera 03: Disable
Power Up Disable
[CANCEL] [OK]
Camera 02: YES
Use this menu to:
• Enable or Disable cameras individually
• Configure the unit to disable cameras automatically at power-up
if video loss is detected.
• Automatically disable all inputs detecting videoloss.
Individual Disable
Use this menu to Disable or Enable each camera input
individually.
Use the Jog to navigate and the Shuttle to change the values.
Save changes and exit the menu: Select [OK], then press
the Enter button.
Exit the menu without making changes: Press the Menu
button, or select [CANCEL], then press the Enter button.
Power Up Disable
With this feature turned On (Enabled), the unit will automatically detect
which inputs are experiencing videoloss at power-up, and
disable them.
Rotate the Jog to navigate and the Shuttle to change the values.
Camera 01:
Camera 02: Enable
Camera 04: Enable
:
:
Camera 16: Enable
Disable
Disable
OFF
Auto Disable Now
This feature detects which inputs have video signals and which are experiencing videoloss. When this
feature is activated, the unit will automatically disable the inputs experiencing videoloss. The DVMRe
Triplex will also re-enable video inputs that were previously disabled if a video input signal is detected.
q Main Menu → Camera Setup → Covert Camera
This feature removes cameras from all live displays while continuing
to record them, so that the users and the public are unaware that the
camera is being recorded. Covert cameras are not viewable during
playback.
Select Yes in this menu to configure a camera as covert.
Rotate the Jog to navigate and Shuttle to change the values.
To disable the covert camera (make display visible) return to this menu
and change the selection to NO. The camera’s display will become visible
upon exiting the Main Menu.
Covert Camera
Camera 01:
Camera 03: NO
Camera 04: NO
:
:
Camera 16: NO
NO
0150-0193G 54 DVMRe Triplex
Luminance Histogram
Luminance
q Main Menu → Camera Setup → Camera Scope
Use this menu to view a live luminance histogram of the currently displayed camera.
Luminance Histogram
A Luminance Histogram is a graphical representation of how many times each gray-level value occurs in
an image.
Use this feature to analyze and optimize the video input signal.
%L
0
Black
White
q Main Menu → Camera Setup → MonB SVHS
Use this menu to enable or disable SVHS output on Monitor B. Select Enable or Disable from the menu
and press Enter. A confirmation screen will appear. Select from Yes or No and press Enter. The output
of monitor B will change immediately.
0150-0193G 55 DVMRe Triplex
3.15 Archive Setup
G.711
OFF
Data recorded by the unit can be archived to an external
archive device.
Use this menu to:
• Select the Port where the archive device will be connected.
• Turn Background Archiving mode Off and On.
• Erase the recorded data on a compatible archive device.
• Enable or Disable QuickWave Setup.
q Main Menu → Archive Setup → Port Select
Select the Port or interface to which the archive device will be connected.
Select from the following items.
Background Archive: Commands the unit to record data to both the
hard disk and the archive device simultaneously.
Select from the following items.
OFF: Turns background archiving Off.
ON: Turns background archiving On.
Port Select
Background Archive
Erase Archive Medium
QuickWave Setup
ON
q Main Menu → Archive Setup → Erase Archive Medium
Use this feature to erase all of the recorded data on an
archive device.
With Erase Archive Medium highlighted, press the Enter
button. If a compatible archive device is connected, a
confirmation box will appear, otherwise no action will occur.
q Main Menu → Archive Setup → QuickWave Setup
This feature provides the option of having the QuickWave software
written to any CDs that are created. This allows the CD to be read
on any PC without installing software. Select ON to enable, OFF to
disable.
3.16 Audio Setup
Use this menu to enable or disable the audio feature of the Triplex. Select
from:
• OFF
• G.711
Message
Erase all Records. Are you sure?
YES
QuickWave Setup
QuickWave CD Write: ON
[CANCEL] [OK]
OFF
0150-0193G 56 DVMRe Triplex
Audio Limitations:
POTS Setup
RS485
POTS Setup
1. To record audio at least one the unit’s video inputs must be set to record video at a rate of 1pps
or faster.
2. If all the cameras are set to EVENT mode and no events are occurring, no audio will be recorded
regardless of the event recording speed.
3.17 Communications
Use this menu to:
• Configure the baud rates and settings for the RS232 ports.
• Configure the network address for the RS485 network.
• Configure the Ethernet address and networks settings.
RS232
Ethernet
q Main Menu → Communications → RS232
Select the Port you wish to configure and press the ENTER button.
Port 1
Port 2
Port 1
Use this menu to:
• Enable/Disable POTS and configure the Modem initialization
string (POTS Setup).
Baud Rate
• Adjust the Baud rate.
POTS Setup
The default modem string (shown below) is for use with Hayes Accura 56k, Diamond Supra Express
56k, and 5686 US Robotics modems in their default conditions. Consult with the modem manual
before attempting to make any changes. It is strongly recommended that the modem initialization
string only be modified by a qualified technician.
SEQ key selects character bank
‘1’ key inserts blank character
‘2’ key inserts selected character
0150-0193G 57 DVMRe Triplex
1. With the Modem Init String highlighted, press the Enter button to enter the Edit mode. The
1200 Baud
2400 Baud
4800 Baud
19200 Baud
38400 Baud
57600 Baud
1200 Baud
2400 Baud
4800 Baud
19200 Baud
38400 Baud
57600 Baud
character bank will appear in the center of the menu.
2. Press the Sequence button to select the desired character bank.
3. Rotate the Shuttle to navigate the Modem Init String.
4. Rotate the Jog to select a character from the character bank.
5. Use the Number 2 button or rotate the Shuttle to insert the desired character from the character
bank into the Modem Init String and advance to the next character.
6. Use the Number 1 button to insert a blank character.
7. When finished, press the Enter button.
8. To save the changes and reboot, select OK, then press the Enter button. The unit will only reboot
if changes were made to the Modem Init String.
9. To exit the menu without making changes, select Cancel, then press the Enter button. Pressing
the Menu button also exits the menu without making changes.
Baud Rate
Use this menu to configure the baud rate for Port 1. Rotate the
Jog to select a baud rate from the menu.
Save changes and exit the menu: Press the Enter button.
Exit the menu without making changes: Press the Menu button.
9600 Baud
Port 2
Use this menu to configure the baud rate for Port 2. Rotate the
Jog to select a baud rate from the menu.
Save changes and exit the menu: Press the Enter button.
Exit the menu without making changes: Press the Menu button.
The RS232 port 2 is used for Event Generation and ASCII Text
Insertion. See Section 7 for the RS232 Protocol required to perform
these functions.
q Main Menu → Communications → RS485
Connect several units to a single keyboard, or vice-versa. Up to
32 units (any combination of multiplexers and keyboards) can be
networked together. Use this menu to specify the units unique network address.
Save changes and exit the menu: Press the Enter button.
Exit the menu without making changes: Press the Menu button.
9600 Baud
Network Address
01
0150-0193G 58 DVMRe Triplex
q Main Menu → Communications → Ethernet Settings
An ethernet connection can be used to connect to the unit from a
PC for the viewing of live or recorded images. Use this menu to
configure the Ethernet communications settings. Select from the
following:
Ethernet: Select Enable or Disable.
Hostname: The default Hostname is the unit’s serial number
without the dashes. The user should modify only when GnuDIP
is selected in the Name Service field.
DHCP: Select Enable or Disable. Enables dynamic IP addressing.
When DHCP is enabled, the IP address, Subnet Mask, Gateway,
and Server fields are dynamically addressed.
Name Service: Select from Disable, WINS or GnuDIP. Enabling
WINS registers the hostname and IP address within the current
Network. This ensures that you can connect to the Triplex by
hostname within the network. See the Note below for information
on configuring Dynamic DDS with GnuDIP.
DDNS Update Interval: Select the Dynamic Domain Name Server
interval. Select from Disable or from 1 to 1440 minutes.
IP Address / Subnet Mask / Gateway: Consult with a qualified Network Administrator or an MIS
professional to configure these settings if DHCP is not enabled.
Primary Name Server / Backup Name Server: The IP addresses of the Primary and Backup Name
Servers. Not required if DHCP is enabled.
Print Server: Enter the Print Servers IP address to enable the Print Image operation (Function and
Zoom).
TCP MTU Size: Select from Standard, 1400, and 1200. The MTU describes the maximum possible TCP
packet size. Standard (1500) is optimal for most ethernet network environments.
HTTP Port : Select the HTTP Port. Select from Port 0 to 65535. Shortcuts are available for port 80
(Camera 1 button) and 8080 (camera 2 button). Consult with a qualified Network Administrator or an MIS
professional to configure these settings.
In order to use Dynamic DNS with GnuDIP, the user has to configure following in the menus:
NOTE
• Name Service must be set to GnuDIP (Ethernet Setting Menu).
• Primary Name Server must be set to the IP address of the GnuDIP server (Ethernet
Setting Menu).
• Hostname must be set to the required hostname format e.g. ge04.companyname.net.
For registration purposes, the string until the first dot is used as hostname (here: ge04),
the remainder is used as domain (here: companyname.net). The hostname is set via
the Ethernet Setting menu and is case sensitive.
• DDNS update interval must be set to a reasonable value (e.g. 2 minutes).
• The password for the DDNS server has to be set in the Passwords->DDNS password
menu. The password is 4 digits long (The Enter button can be used for the number 0).
When everything is configured correctly, the DVMRe will send periodically a Dynamic DNS
update message over TCP port 3495 to the Dynamic DNS server telling the server its
hostname. The DVMRe does not include its IP address in the message. Instead the Dynamic
DNS server extracts the IP address of the DVMRe via the Ethernet source IP address. This
guarantees that the correct IP address is used even when the DVMRe is behind a NAT router.
0150-0193G 59 DVMRe Triplex
Installer Password
3.18 Front Panel Lock
Use this feature to lock the front panel keypad. While locked,
the only operational key on the front panel is the Menu button.
To unlock the front panel, enter the Installer password and return
to this menu.
Highlight the item you wish to select.
Save changes and exit the menu: Press the Enter button.
Exit the menu without making changes: Press the Menu button.
3.19 Factory Settings
Return To Factory Defaults
From the Factory Setting menu, press the Enter button. A
password box will appear. Enter the Factory Default password.
Select OK, then press the Enter button.
Unlock Keyboard
Lock Keyboard
Factory Default Password
10 and 16-Channel
8 1 1 1
The unit will reboot, returning all settings (except the time, date,
email addresses, and email IP address) to the factory defaults.
Due to the large size of the hard disk, the reboot may take several
minutes.
Change Language
From the Factory Setting menu, enter the Language password.
A menu will appear displaying the available language selections.
Rotate the Jog to select the desired language.
Save changes and exit the menu: Press the Enter button.
Exit the menu without making changes: Press the Menu button.
Available Languages:
English French German
Italian Russian Polish
Czech Finnish Hungarian
Slovak Spanish Dutch
Danish
4-Channel
Language Password
10 and 16-Channel
4-Channel
4 1 1 1
5 4 1 5
1 4 1 4
3.20 Passwords
0150-0193G 60 DVMRe Triplex
Use this feature to change the Installer, Operator or Ethernet passwords.
Operator Password
Ethernet Password
Changing the Installer or Operator Passwords
-
-
To change the password:
1. Highlight the password you wish to change, then press the
Password Box
Enter button. A password box will appear.
2. Enter the new password using the Number buttons.
3. Highlight OK, then press the Enter button.
Enter a new Install Password
---
4. Re-enter the password.
5. Highlight OK, then press the Enter button. The user will be
prompted, indicating if the password was entered correctly
and changed.
The Ethernet Password
The Ethernet Password feature limits access to only those
users who access the unit using the password feature of
WaveReader versions 2.3 or later. When the unit is first setup,
the default is No Password Protection. Meaning, anyone
using WaveReader and accessing with an ethernet connection
can connect to the unit.
Enter a new Ethernet Password
Password Box
---
Activate The Ethernet Password
1. Enter the new password using the Number buttons.
2. Highlight OK, then press the Enter button.
3. Re-enter the password.
4. Highlight OK, then press the Enter button. The user will be prompted, indicating if the password was
entered correctly and changed.
Deactivate The Ethernet Password
To return the unit to No Ethernet Password Protection,
enter the Ethernet Access Reset Password in the
password box shown above.
The DDNS Password
The DDNS password enables the DVMRe Triplex to contact
the Domain Name Server in order to provide IP to Domain
Name translation. You must obtain this number by calling
you Domain Name Service. By default this password is
2222. This password is only used when Name Service in
the Ethernet Settings Menu is set to GnuDIP.
Ethernet Access Reset Password
1 1 1 1
0150-0193G 61 DVMRe Triplex
3.21 The QuickInstall Menu
Edit Camera Titles
Installer Password
Sequencing
QuickInstall Menu Overview
After installation is complete, it is strongly recommended that, as
a minimum, the items in the QuickInstall menu be configured
before the unit is used.
All items located in the QuickInstall menu are also found in the
Main menu. These items are provided in the separate QuickInstall
menu as a convenience for the installer.
Use the following table to find detailed information about configuring
specific items from the QuickInstall menu.
QuickInstall Menu Item
Change the time
Change the date
Edit Camera Titles
Camera Disable
Record Quality
Main Menu → Time/Date → Set Time
Main Menu → Time/Date → Set Date
Main Menu → Camera Setup → Camera Titles
Main Menu → Camera Setup → Camera Disable
Main Menu → Record → Record Quality
Primary Menu Location
Change the time
Change the date
Camera Disable
Record Quality
Auto Disable Now
Section In
Manual
3.8
3.8
3.14
3.14
3.10
Installer Password
Auto Disable Now
Main Menu → Passwords → Installer Password
Main Menu → Camera Setup → Camera Disable
→ Auto Disable Now
3.22 The Operator Menu
The Operator Menu Overview
The Operator menu is provided so that the user has access to a
limited number of menu items. These menu items are primarily
monitor display setup options, so that the user may “personalize”
the monitor displays during their shifts. Other options include video
archive setup and changing the operator password.
None of the items are unique to the Operator menu. All items
located in the Operator menu are also found in the Main menu.
3.20
3.14
Time/Date Display
Titles Display
Alarm History
Archive Setup
Operator Password
0150-0193G 62 DVMRe Triplex
Use the following table to find detailed information about configuring specific items from the Operator
About DVMR
View Screen 10
Serial Number:
Boot Code Version:
OK
menu.
Operator Menu Item Primary Menu Location
Sequencing
Time/Date Display
Titles Display
Main Menu → Sequencing
Main Menu → Time/Date → Time/Date Display
Main Menu → Camera Setup → Camera Titles →
Title Display
Alarm History
Video Archive Setup
Operator Password
Main Menu → Alarm → Alarm History
Main Menu → Archive Setup
Main Menu → Password → Operator Password
3.23 The SystemView Menu
The SystemView Menu Overview
The SystemView menu is provided so that users may quickly view global
software and hardware settings.
About DVMR menu: This menu provides information
such as:
• Model Designation
• Serial Number
• Hostname
• Software Version
• Software Date
• Boot Code Version
• Hard Disk Size
• IP Address
• Hardware Address (MAC)
• DHCP Lease Expiration Date
• Last DDNS Update Status
• Last DDNS Update Success
Model:
Hostname:
Software Version:
Software Date:
Disk Size:
IP Address:
Hardware Address:
DHCP Lease Expires:
Last DDNS Update Status:
Last DDNS Update Success:
DVMRe-16CT
D406-T2-250419
D406T2250419
VER 5.20
Jan 07 2004 09:44:13
VER 1.03
163.93 GB
3.18.173.10
BA-BE-C6-7E-FA-CE
No Lease or Date
No attempt
NONE
0150-0193G 63 DVMRe Triplex
View Screens 1 through 10: These menus provide an overview of the units current operating
parameters and the menu settings selected by the user or installer. Each View Screen is described in
the following tables. The default values are bolded and italicized.
The View Screens
View Screen 1
Alarm Input
• Enable/Disable: 1 = Enabled, 0 = Disabled
• Normally Open or Normally Closed: 0 = Open, C = Closed
• Macro: Macro number if activated.
Alarm Action
• Freeze: 1 = Freeze, 0 = No Freeze
• Cameras: Primary camera in alarm and three associated cameras.
• Relay: 1, 2, 1+2, or None.
• Intrusion AND/OR:AND, OR
View Screen 2
Camera
• Enable/Disable: 1 = Enabled, 0 = Disabled
• Signal Gain: AGC setting from 1 through 100. 50
• Covert Camera: Yes or No
• Camera Title: Camera x, x=number
Videoloss Action
• Relay 1: 1 = Enabled, 0 = Disabled
• Relay 2: 1 = Enabled, 0 = Disabled
• Buzzer: 1 = Enabled, 0 = Disabled
View Screen 3
Motion Detection
• Enable/Disable: 1 = Enabled, 0 = Disabled
• Activity or Intrusion Detection: I = Intrusion, A = Activity
• Sensitivity: 1 through 10, 5
• Relay Output: None, 1, 2, 1+2
• Link to Event: Yes or No
• Rejection Ratio: High, Medium, or Low
• Target Size: 1 through 256
• Alarm Camera: 1 through 4, 10 or 16
0150-0193G 64 DVMRe Triplex
View Screen 4
Record Rate
• Event Camera Settings: T = Timelapse, E = Event, ET = Event and Timelapse
• Timelapse Record Rate: In pictures per second (pps). 30 spp
• Event Record Rate: In pictures per second (pps). 1 pps
• Pre Event Duration: 0 to 5 seconds. 2
• Post Event Duration: 0 to 200 seconds. 0
• Acitvity Record Rate: In pictures per second (pps). 2 spp
• Disk Test: Test Now, Test Periodically or Disable.
• Test Frequency in hours: 0 – 1000.
• Test Duration: Fast or Thorough.
• Disk Test Results: Disk Test Success or Disk Test Failed.
0150-0193G 66 DVMRe Triplex
4 Alarms
4.1 Alarm Input
Alarm devices are connected via the Alarm PCB on the back panel of the unit (see section 1.7). Each
Alarm Input corresponds with the Camera Input of the same number. Alarm input to camera number
assignments can be changed on 10 and 16-channel models. See Alarm Action menu (section 3.11).
4.2 Alarm Output
Front Panel Alarm LED: The LED located to the left and above the Alarm button is lit for the duration
of the alarm.
Internal Buzzer: The internal buzzer is activated until it is Silenced and Acknowledged. This feature
can be turned off in the menu system (see Buzzer Setup in section 3.11).
Monitor Displays: Discussed below in the On-screen Displays During Alarms section.
Output Relays: The alarm output relays are active for the duration of the alarm. This feature is
configured in the menu system (see Alarm Action and Relay Configuration in section 3.11) and can be
deactivated.
Macro Activation: Unit can be configured in the menu system to activate a macro when an alarm is
detected.
Preset PTZ Camera commands: Unit can be configured in the menu system to send preset
commands to specific cameras when an alarm is detected.
Record Rate: Record Rate can be increased by recording at the Alarm Record Rate (see section
3.10) and by Interleaved or Exclusive Recording (see Alarm Record mode in section 3.11).
4.3 Alarm Acknowledge
Pressing the Alarm button acknowledges to the unit that the alarm has been recognized and silences
the internal buzzer. This does not clear the alarm condition.
4.4 On-screen Displays During Alarms
10 and 16-Channel Units
Monitor-A in Live Multiscreen Mode
Single Alarm: When a single alarm is received, the unit changes to 4-way
display containing the camera in alarm, and three associated cameras. The three
associated cameras are defined as a group in the menu system (see Alarm
Action in section 3.11). The top left cameo displays the camera in alarm.
Second Alarm: When a second alarm is received, the unit changes to a 10-way
multiscreen, displaying the alarm cameras in the top two cameos. The
associated cameras are displayed in the remaining cameos.
Third Alarm: When a third alarm is received, the unit changes to a 9-way
multiscreen, displaying the alarm cameras in the top three cameos. The
associated cameras are displayed in the remaining cameos.
More than three alarms simultaneously: The unit switches to the maximum
multiscreen display, i.e. 16 or 10-way.
4-Way
Single Alarm
10-Way
Second Alarm
9-Way
Third Alarm
0150-0193G 67 DVMRe Triplex
Other display options include:
LIVE MODE
PLAYBACK MODE
Monitor A
Monitor A
Monitor B
Monitor B
• A full screen display of a single camera in alarm, with a sequenced full screen display for
additional cameras in alarm. This option is selectable in the menu system (see Full Screen Alarm
in section 3.11).
• Freeze camera display at the time the alarm was received.
Monitor-B Display During Alarm
Single Alarm: Unit switches to a full screen display of the camera in alarm.
Additional Alarms: Unit switches to a sequenced display of all cameras in alarm.
4-Channel Units
Single Alarm: Unit switches to a full screen display of the camera in alarm.
Additional Alarms: Unit switches to a sequenced display of all cameras in alarm.
4.5 Alarm Operations During Playback
Live Alarms Displays
Single Alarm: Unit switches to a full screen display of the camera in alarm on Monitor B.
Additional Alarms: Unit switches to a sequenced display of all cameras in alarm on Monitor B.
LIVE
LIVE ALARM
A
LIVE
LIVE
LIVE ALARM
FULL
SCREEN
ALARM
PLAY
BACK
LIVE ALARM
PLAY
BACK
LIVE
LIVE ALARM
FULL
SCREEN
ALARM
0150-0193G 68 DVMRe Triplex
Recorded Alarms
Internal Buzzer: During playback, the internal buzzer is activated until it is silenced and
acknowledged. This feature can be turned off in the menu system (see Playback Buzzer, Buzzer
Setup in section 3.11).
Front Panel Alarm LED: The LED located to the left and above the Alarm button is lit for the duration
of the alarm.
Monitor-A Multiscreen: Each camera in alarm is indicated on-screen by a flashing red “A” in its
cameo. Alarm LED lights to indicate an alarm condition. There is no change in the playback (or
Triplex) multiscreen based on playback of recorded alarms.
4.6 Alarm History Box
The Alarm History feature provides a list of the 100 most recent alarms. View the Alarm History Box
by accessing the menu system, and selecting Operator → Alarm History. The Alarm History Box
can also be found under Main Menu → Alarm → Alarm History. For detailed information about
viewing the Alarm History Box see Alarm History in section 3.11.
4.7 Searching For Recorded Alarms
See section 5.
0150-0193G 69 DVMRe Triplex
Play Back
Search Filters
Enter
Enter
Search
Search Filters
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Search Results
‘ENTER’ to play event; ‘SEQ’ to repeatedly play event.
5 Searching
The DVMRe Triplex is equipped with a powerful search interface to access video files stored on the
hard disk or an external archive device.
Search Menu Overview
Button
Disk Analysis Screen
Disk Analysis Screen
Disk Analysis Screen
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Alarm Event Activity Videoloss Present Absent
Hit SEARCH again to enter Advanced SearchLevel 1
01/21/2002 20:17:01
Motion Search
Search
Button
Motion Search
Last 2hrs
Last 8hrs
Last day
Last 7 days
Last 4 weeks
Last 12 weeks
X
Custom
Activity Setup
Activity Setup
Enter
Search
Button
Operation: Play from Disk
DATE (MM/DD/YY) TIME (HH:MM)
Start Stop Start Stop
01/27/04 01/27/04 20:57 20:59
Activity Event Alarm Text
X
Retail
X
Camera
X
X X X X X X X X X X X X X X X
[CANCEL]
[START SEARCH]
Hit ‘ZOOM’ to edit retail text list
Hit ‘ENTER’ to toggle EDIT Mode
‘PLAY REV/FWD’ to page up/down
‘ENTER’ to play event; ‘SEQ’ to repeatedly play event.
Search Results
Enter
Activity, Text, Alarm Search Results
3/19 06:11
3/19 21:42
02
3/20 21:54
02
3/19 23:51
02
3/21 02:25
02
02
3/20 18:51
02
10 matches found.
‘PLAY REV/FWD’ to page up/down
3/20 6:26
02
3/21 03:51
02
Search
Button
3/20 14:30
02
3/22 21:01
02
0150-0193G 70 DVMRe Triplex
5.1 Disk Analysis Screen
Level 1
Disk Time
Record
Button
Archive Incident
Begin by pressing the Search button. The Disk Analysis Screen will appear.
This screen shows a graphical representation of the recorded video stored on the
internal hard disk.
Arrow Cursors
02/28/2002 20:45:00
Search Button
Disk Analysis Screen
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Alarm Event Activity Videoloss Present Absent
Hit SEARCH again to enter Advanced SearchLevel 1
01/21/2002 20:17:01
01/21/2002 20:17:01
and Date
at cursor
location.
Zoom
Level
Write to CD
Rotating the Jog moves the two arrow cursors across the representation of the recorded video. As the
cursors move across the screen the corresponding disk time is indicated in the upper right of the screen.
The video representations are color-coded by category. Rotating the Shuttle expands (Zooms) the
display. The Lowest level (most detail) is indicated on screen with an (L). Pressing the Enter button will
start Playback from the cursor location.
5.2 Quick Archive to CD
Archive to CD on the Disk Analysis Screen by selecting the time and date and pressing the record
button. The QuickWave Setup must be set to ON from the Archive Setup → Quick Wave Setup menu
(see section 3.15). The Archive Incident menu should appear.
1. Use the Jog to modify the time parameters and use the
Shuttle to move between the Start and Stop fields.
2. Press the Record button on the front panel when satisfied.
3. The CD Writer will open the CD tray when completed.
The video may now be viewed on any PC equipped with a CD-ROM.
0150-0193G 71 DVMRe Triplex
07/31/2003 02:20:06P
Start Stop
02:02:51P
Capacity: 557MB
‘RECORD’ to Archive
02:20:09P
‘MENU’ : Exit Activity Setup
‘ENTER’: Save and Exit Activity Setup
‘PAUSE’: Toggle between Enable and Neutral
‘STOP’ : Toggle between Disable and Neutral
Button
5.3 Motion Search
Pressing the Search button a second time will bring up the Motion Search menu. This menu performs a
motion search with six preset time parameters and a custom search option. Rotate the Jog to navigate
and the Shuttle to select a specific parameter. Selecting the Custom option and pressing the Enter
button starts playback and brings up another window with Start/Stop, Time/Date options. These options
provide the parameters to focus the search to a specific time period.
Motion Search
Last 2hrs
Last 8hrs
Last day
Last 7 days
Last 4 weeks
Last 12 weeks
X
Custom
Selecting any of the other options and pressing Enter starts playback and displays the Motion Search
Setup Screen.
This screen overlays the current playback video and allows the user to enable or disable motion
detection on the screen within blocks that form a 16 x 16 grid.
Pressing the Function key while in this screen overlays a help screen with all the available
commands.
{F}
Function
0150-0193G 72 DVMRe Triplex
5
‘ZOOM’ : Disable/Enable all zones
Pressing Enter upon completion of the activity setup will start the search and launch the Search
Search Filters
3. Copy from Disk to Archive.
4. Copy from Archive to Disk.
XXXXXXXXXXX
Results window. See section 5.4 for operating instructions.
5.4 Search Filters
Pressing the Search button a third time brings up the Search Filters Menu. Use the Search Filters menu
to specify:
• The type of operation to be performed: Play from Disk, Play from Archive, Copy from Disk to
Archive, and Copy from Archive to Disk.
• The Start and Stop date of the search.
• The Start and Stop time of the search.
• Searching for recorded activity, events, retail text, or alarms.
• Searching for a text string.
• Which cameras to search inclusively or exclusively.
Operation: Play from Disk
DATE (MM/DD/YY) TIME (HH:MM)
Start Stop Start Stop
01/27/04 01/27/04 20:57 20:59
X
[CANCEL]
[START SEARCH]
Hit ‘ZOOM’ to edit retail text list
Hit ‘ENTER’ to toggle EDIT Mode
Activity Event Alarm Text
Retail
X
X
Camera
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
X
XXXXXXXXXXXXXXX
XX XX X
EDIT MODE
The following options are
available when an archive
device is connected:
1. Play from Disk.
2. Play from Archive.
Selecting these functions
displays thumbnails in
the Search Results window.
To access the Retail Search
Menu select ‘RETAIL’
and press the ‘ZOOM’ key.
Hit Camera buttons to
select/deselect individual
cameras. Use the Zoom
button to globally
select/deselect cameras
to search.
Selecting Search Parameters
1. Rotating the Jog to navigate, highlight the box adjacentto the parameters that you wish to modify.
2. Once in the Parameter Box, use the Shuttle to navigate through the fields and the Jog to change
3. To activate the parameter, use the Shuttle or the Enter button to place an [X] in the check box.
4. When finished, use the Jog to navigate to another parameter.
0150-0193G 73 DVMRe Triplex
the values.
5.5 Retail Search
filename: retail_search.txt
The local retail search feature is provided for customers who wish to search video for specific products
from the front panel of the DVMRe. The customer can select from predefined product names from
predefined categories. To use this feature you must create a text file containing the categories (product
types) and product names (sub levels) that you want to search. This file is then uploaded to the DVMRe
via the web interface.
Text File Format
To create a retail search text file open Notepad or any other simple text editor. The file must be saved as
a text only file. The meta-character # is used in this text file to identify a category. All strings below a
category are interpreted as sub levels of that category until another category appears. The creator of the
retail text file is responsible to put the categories and sub levels into correct order. The DVMRe will not
sort the strings. A category has to have at least one sub level. The customer has to store this file as a .txt
file named retail_search.txt.
The retail search text file can be uploaded to the DVMRe unit via the Web interface. The index.ssi page
will contain a link to the retail search page. Open the embedded web browser by typing the DVMRe’s IP
address in the address field of your Internet browser.
Click here
This page will appear if no retail text file has previously been uploaded. To upload the file, click the
Browse button and navigate to the file location. Once the file is selected, click on the Upload Retail
Search File button.
0150-0193G 74 DVMRe Triplex
Setup Retail Search
Hit ‘ENTER’ to toggle EDIT Mode
[CANCEL]
Ice Cream selected
from Category List
X
When the retail text file has been uploaded this page provides the options to delete or upload a new retail
text file. The user can view the retail text file by clicking the link to the retail text file. The user can
download the retail text file to a PC by right-clicking the link and by choosing 'Save Target As'. The user
can only upload one retail text file and can delete the current retail text file. After uploading the file (and
also after a reboot), the DVMRe will read the contents of the file and store it in memory.
The Local Retail Search Screen
Access to the Local Retail Search screen is gained through the Search Filters Menu. Press the Search
button one or more times until the Search Filters Screen appears, then select the Retail radio box and
press the Zoom key.
Search Filters
Operation: Play from Disk
DATE (MM/DD/YY) TIME (HH:MM)
Start Stop Start Stop
01/27/04 01/27/04 20:57 20:59
Activity Event Alarm Text
X
Retail
X
X
Camera
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
X
X X X X X X X X X X X X X X X
[CANCEL]
[START SEARCH]
Hit ‘ZOOM’ to edit retail text list
Hit ‘ENTER’ to toggle EDIT Mode
EDIT MODE
To access the Retail Search
Menu select ‘RETAIL’
and press the ‘ZOOM’ key.
0150-0193G 75 DVMRe Triplex
Catagories
Sub Level
Selected Strings
Clear Individual
(1)
Clear All
[OK]
Ice_Cream
Soda
(3)
Beer
X
Vanilla
(2)
Chocolate_Chip
X
Vanilla
Vanilla selected
from Sub Level
The following operations can be performed on this screen:
• Select category in the categories list.
• Select and deselect sub levels of the currently highlighted category.
• Clear individual or all selected sub levels.
3 categories, 5 sub levels, and 5 selected sub levels can be displayed on screen at one time. Up/down
keys will scroll the screen backward and forward. The user can select sub levels from different categories
by first selecting the category, then going to sub level frame and highlighting the selection. The user
selections are kept in non-volatile memory so they survive a reboot. The user selections will be cleared
when the user uploads a new retail text file. Like the other text searches, the results will display in
thumbnail pictures and can be viewed through full screen playback with text.
Restrictions and Limitations
• The limit of the search strings is 1000. For example there might be 50 categories and 950 sub
levels.
• It is not possible to have a second sub level (e.g. Soda>Diet Soda>Root _Beer).
• It is not possible to do a normal text search and a retail search at the same time.
• The characters #, *, and @ are meta characters and are not to be used in the text string.
• It is not possible to search for categories. In the previous retail search text file for example, the
user cannot search for Beer.
• Only the first word of a sub level will be searched. For example, when the sub level 'Chocolate
Chip' is selected, only the word 'Chocolate' will be searched for. The search string cannot contain
blank characters or spaces and is not case sensitive.
• Only the first 30 characters of a category or sub level are displayed.
• The user can select up to 25 sub levels and search them simultaneously.
• A maximum of 200 matches are available for each specific search. The user can further modify
searches by selecting time limit and cameras.
5.6 Search Results
Activate Search
From the Search Filters menu, use the Jog to navigate to the Start Search parameter. With the Start
Search parameter highlighted, press the Enter button to begin the search operation. When finished
searching, the Search Results window will appear. A maximum of 200 results can be displayed per
search. Two types of Search Result windows will appear depending on the type of search that is
performed.
0150-0193G 76 DVMRe Triplex
Search Results
Activity, Text, Motion, Alarm Search Results
‘ENTER’ to play event; ‘SEQ’ to repeatedly play event.
Time/Date Search Results
Search Results
Start Date Start Time Days HH MM SS
000 01/21/2002 20:07:10 0 04:35:15
3/19 06:11
02
3/20 18:51
02
10 matches found.
‘PLAY REV/FWD’ to page up/down
‘ENTER’ to play event; ‘SEQ’ to repeatedly play event.
Follow the directions on-screen to select, archive, playback, etc.
Search Results
3/19 06:11
02
3/20 18:51
02
3/19 21:42
02
3/20 21:54
02
3/19 23:51
02
3/21 02:25
02
3/20 6:26
02
3/21 03:51
02
3/20 14:30
02
3/22 21:01
02
10 matches found.
‘PLAY REV/FWD’ to page up/down
‘ENTER’ to play event; ‘SEQ’ to repeatedly play event.
Some options may be unavailable depending on the type of search performed. These options are not
displayed. When archiving, the unit will not allow the amount of selected data to exceed the amount of
space available on the target medium.
Press the Menu button to exit the Search Results window without making a selection.
Hitting the Enter button will play the selected search result.
Hitting the Enter button again while in playback will cause the next selection from the search list to be
played.
Press the Sequence button to repeatedly play the selected event.
0150-0193G 77 DVMRe Triplex
6 WebBrowser
The DVMRe Triplex has an integrated WebBrowser interface. The WaveBrowser option allows the user to
view video from any ethernet connected Triplexes with software version 4.09 or above.
For WaveBrowser to function properly, certain ActiveX controls must be set correctly. To
NOTE
setup the ActiveX controls:
1. Click on the Tools → Internet Options Menu in Internet Explorer.
2. Click on the Security tab.
3. Select Internet for the Web Content Zone.
4. Click on the Custom Level button.
5. Ensure that both Download unsigned ActiveX controls and Initalize and Script
ActiveX controls not marked as Safe are set to Prompt.
6. Click the OK button.
7. Click on the Yes button in the Warning message.
8. Click the OK button in the Internet Options window.
To access the web interface:
1. Launch Internet Explorer (version 5.5 or later) on any local Internet connected PC or laptop.
2. Type in the Triplex’s IP address or hostname in the address field and press enter. The Enter
Network Password box should appear.
3. Enter the correct Username and Password in their respective fields (the default username and
password is admin). Click the OK button.
4. The WaveBrowser window should appear. Type the IP address in the IP Address Field and click
the Connect button.
IP Address Field
0150-0193G 78 DVMRe Triplex
Main Viewing
Drop Down
Volume List
6.1 WaveBrowser Overview and Controls
Button Panel
Area
The Main program window consists of the following areas:
• The Main Viewing Area: The large blue area.
• The Button Panel: The left side of the window.
• The Drop Down Volume List: Allows the selection of available Disk volumes.
The Main Viewing Area
Pictures are displayed in this area in Multi-Camera, and Single-Camera formats. Picture display order
is according to the information encoded by the unit used to create the original video data file.
Choose from the following displays:
• 16-way Multiscreen Display (Large and Medium)
• 4-way Display
• Single Camera Display Large
• Single Camera Display Medium
• Single Camera Display Small
0150-0193G 79 DVMRe Triplex
The Button Panel
3467891415181920211716121311105
1. Play Backward button: Click on this button to playback video in
reverse.
2. Stop button: Click on this button to halt all playback operations. The
Play Pointer Slider Bar moves to the start of data.
3. Play Forward button: Click on this button to playback video.
4. Single Frame Rewind button: Click on this button to rewind the video a
single frame.
5. Pause button: Pauses playback until the Pause button is pressed
again. Clicking any of the buttons, except Stop will also resume
playback. The Play Pointer slider bar stays at the current position while
paused.
6. Single Frame Advance button: Click on this button to advance the
video a single frame.
7. Rewind button: Click on this button to perform high-speed reverse
playback.
8. Fast Forward button: Click on this button to perform high-speed
playback.
9. IP Address Field: Enter the unit’s IP address.
10. Password Field: Enter the unit’s password, if necessary.
12
11. Live check box: Click in this box to enable live viewing before connecting.
12. Connect/Disconnect button: Click on this button(s) to connect to the unit.
13. Number buttons: Press any of these buttons to call up individual cameras for display. When
connected to a unit that has more than 16 cameras, right-clicking over the number buttons will
display numbers 17 through 32. Right-click again to return to cameras 1 through 16.
14. Single Camera Display Size: Choose from Small, Medium, or Large.
15. 16-way Multiscreen button: Choose from a Medium 16-way, or Large 16-way.
16. 4-way Multiscreen button: Selects a Large 4-way display.
17. View Live Button: Click on this button while connected to view live video.
18. Play Pointer Slider Bar: The Play Pointer slider bar advances to the right to indicate the playback position on the disk. The user can drag the bar to navigate forward or backward.
19. Goto Button: Click on this button to go to the selected date for the drop down time and date boxes.
20. Drop down Date Selection Menu: Click on this field to display a graphic calendar to select a date to view.
21. Time Selection Menu: Click on the Up or Down Arrows to select a specific time to view.
The Drop Down Volume List Box
Click on the arrow to display a list of available disk volumes on the connected unit. Click on the volume
to select.
0150-0193G 80 DVMRe Triplex
6.2 DVMRe Triplex WaveLink
A new feature with Triplex software version 5.00 is the DVMRe Triplex WaveLink. This feature allows
putting command codes in the URL when calling WaveBrowser to control actions the WaveBrowser is
going to perform.
This feature can be used by Web Developers to link various cameras to specific Web content. It will
also be used by the DVMRe Email feature to allow the recipient of an alarm email to click on a link in
the email, which causes the WaveBrowser to connect and play back at the time when the alarm
occurred.
Functionality
The traditional WaveBrowser URL is http://<IP_Address>/wrcontrollite.ssi. This URL will start the
WaveBrowser in the disconnected state. Triplex software version 5.00 supports command codes
placed after an underscore after wrcontrollite and before .ssi. In the following example, the options
are in bold.
The following table specifies the supported options:
Name Code Description Example
Camera c=<n>
Size s=<n>
Action a=<n>
Time t=<n>
Describes either the camera number for
fullscreen (1=Camera 1, …16=Camera
16) or the type of the multiscreen display
(100 = Multiscreen 16 large, 101=
Multiscreen 16 small, 102= Quad
screen)
For fullscreen camera, describes the
size of the display (1=large, 2 =medium,
3= small)
Describes the action the WaveBrowser
has to take:
0 No action
1 Normal Connection Play
2 Normal Connection Live
3 Normal Connection Goto
4 Live Connection
When action is set to 3 (Goto), the time
specifies where to go in number of
seconds since 01/01/1960.
c=10
s=2
a=2
t=1361959858
Please Note: When an option is not specified, it will be set to 0.
NOTE
0150-0193G 81 DVMRe Triplex
When a normal connection is requested, but the DVMRe unit is already connected via a
normal connection, the WaveBrowser should open a live connection instead.
The default page, http://3.18.172.230, does not accept option codes and will open the WaveBrowser in
disconnected state.
The example URL from above (http://3.18.172.230/wrcontrollite_c=1s=2a=3t=1361959858.ssi)
requests the WaveBrowser to make a normal connection, play back at 2/27/2003 10:53:32
displaying camera 1 in medium size.
Email Links
The DVMRe Triplex is able to send emails when certain events occur (like videoloss, alarms, etc.).
When in record mode, the Triplex software version 5.00 will add a WaveBrowser link in the email
notification. It will only add a link in the email if Notify Alarm is set to enable and the link will only
pertain to the Alarm start.
Clicking this link initiates WaveBrowser to be started, make a normal connection and play back the
specific camera with a medium size video window at the time the alarm occurred.
0150-0193G 82 DVMRe Triplex
7 Technical Specifications
General
External Power Supply
12 Volt DC. 60 Watt (5 Amp)
Connector
Power Consumption
Operating Temperature Range
Relative Humidity Range (Non-Condensing)
Dimensions
Weight
Connections
10/100 Ethernet Port
RS232 Port 1
AUX Port
RS232 Port 2
Camera Inputs
Monitor-A Output (Y/C)
Monitor-B Output (Y/C)
Monitor-A Output (Composite)
Monitor-B Output (Composite)
2.1mm barrel connector, center positive.
35 Watt nominal (single hard disk).
Operating: 0 to 40°C. Storage: -20 to +60°C.
Operating: 10% to 80%. Storage: 10% to 95%
17.5 x 14 x 1.7 Inches. 1U, 19 inch rack unit.
9 Lbs.
RJ-45 Connector.
DB-9 Male Connector.
DB-9 Male Connector.
RJ-45 Connector.
BNC connectors. Auto Terminating. Color & Mono.
4-pin Mini-DIN Connector.
4-pin Mini-DIN Connector.
BNC Connector.
BNC Connector.
RS485 Port
SCSI Port
IEEE 1394 Firewire Port
Alarm I/O Port
Two Looping RJ-45 Connectors
50 pin, High Density SCSI-2 female connector.
6 position IEEE 1394 Socket
Use Supplied DB-25 PCB connector.
Video
Video Signal Input
Video Signal Output
Input Termination
Display Memory
Resolution
Gray Scale
Colors
Compression Standard
0150-0193G 83 DVMRe Triplex
0.5 to 2.0 Volts peak-to-peak with Automatic Gain Control.
1 Volt peak-to-peak into 75-Ohm.
75-Ohm (Auto Terminating)
4 Megabytes
Horizontal: 720 Pixels. Vertical: 484 Lines (576 for PAL).
256 levels
Y:U:V 4:2:2, 16.8 Million Colors
Wavelets
Audio
Audio Input
315mV, 40k Ohms. Unbalanced.
Audio Output
Alarms
Inputs
Relay Configuration
Record Priority
Alarm Status Indicators
Motion Detection
Zones Per Camera
Sensitivity Settings
Gray Levels Per Zone
Motion Detection Status
Output
Part Numbers
Remote Keyboard
315mV, 600 Ohms. Unbalanced.
1 per camera.
User programmable as Normally Open or Normally Closed.
Interleaved, Exclusive, or No Change.
Relay Outputs, On-screen Indicators. Status Retrievable via RS232
port.
256: 16 x 16 grid.
10 levels
256 levels
Relay Outputs, Link to Alarms, Link to Events, On-screen Indicators.
Status retrievable via RS232 port.
CBR-KB3, CBR-KB3/J, KTD405. Includes motorized pan, tilt, and zoom
controls.
Rack Mount Kit
Replacement Manual
0150-0193G 84 DVMRe Triplex
CBR-RK6. 1U Height. Part Number: 0110-R601
0150-0193
8 RS232Alarm/Event Generation/Text Insertion
Protocol
The RS232 Alarm/Event Generation /Text Insertion Protocol is designed to deliver Alarm, Event
(commands), and Text data to the DVMRe from serial interface devices through the RS232 port.
NOTE
Setting and Clearing Alarms with this Protocol is equivalent to activating and deactivating
Alarms on the hardware alarm inputs.
8.1 Message Structure
The Delimiter byte signals the start of a new message, and has a value of 0xFF.
The Class and Command fields identify the type of message.
The Data Length is a 16-bit value indicating the number of bytes in the Data portion of
the message. Data Length is sent using Intel byte ordering (Little Endian).
The Check Sum byte is the result of XORing all the bytes in the message.
8.2 Message Type
One message is currently supported to store text along with recorded video.
Delimiter
Class
Command
Data Length
Data
Check Sum
0xFF
CMD_NEW_ADD_TEXT
Class byte is 0x14.
Command byte is 0x40.
Data Length is the number of data bytes in the message (from 2 to 502).
Camera byte indicates the camera associated with the alarm, event, or text. The
valid range is from 0 to 15.
Alarm/Event byte usage is described in the following section.
String fields contain text characters. The string length can be from 0 to 500
characters in length. The String field is not required. If text data is available, it will be
recorded with the next video frame for the camera identified by the camera field.
0x14
0x40
Data Length[0]
Data Length[1]
Camera
Alarm/Event
String[0]
String[1]
:
String[n-1]
Check Sum
0150-0193G 85 DVMRe Triplex
8.3 Alarm/Event Fields
MSB
LSB
Event Start
Alarm Start
Alarm Stop
The two least significant bits are currently used for the Event commands. Bits 2 and 3 are used for the
Alarm commands.
7 6 5 4 3 2 1 0
Event Stop
8.4 Alarm Actions
No Alarm Change – 0000 00XXb
If both the start and stop bits are clear, the alarm status and camera record rates will remain
unchanged.
Start Alarm – 0000 01XXb
If only the start bit is set, the DVMRe will enter the Alarm mode. The selected camera will become the
alarm camera. Pre-alarm video will be recorded and the Alarm Record Rate will be initiated.
Every Start Alarm command should subsequently be followed with a Stop Alarm command
NOTE
at some point. Failure to do so will render that alarm input useless, even if the alarm was
latched and gets acknowledged from the front panel. A Stop Alarm followed by a Start Alarm
will have to be sent to create a new alarm on that channel.
Stop Alarm – 0000 10XXb
If only the stop bit is set, the selected camera’s alarm status will be cleared. If no other alarms are
present, the DVMRe will exit the alarm mode.
Momentary Alarm – 0000 11XXb
If both the start and stop bits are set, a momentary alarm will be initiated on the selected camera. Prealarm video will be recorded at the alarm record rate, after which the DVMRe will continue to record
video at the normal record rate.
0150-0193G 86 DVMRe Triplex
8.5 Event Actions
NOTE
No Event Change – 0000 0000b
If both the start and stop bits are clear, there will be no change to the event status. The camera’s
record rate will not be changed.
Start Event – 0000 0001b
If only the start bit is set, an event will be initiated on the selected camera. This will cause the selected
camera, as well as any pre-event video to be recorded at the Event Record Rate.
Stop Event – 0000 0010b
If only the stop bit is set, the current event on the selected camera will be terminated. This will start
the post-event timer after which, the selected camera will resume recording at the normal record rate.
Momentary Event – 0000 0011b
If both the start and stop bits are set, a momentary event will be initiated on the selected camera. Preevent video will be recorded at the event record rate for the selected camera. The post-event timer will
continue recording at the event record rate, after which the selected camera will resume recording at
the normal record rate.
All Event messages will be ignored while an Alarm condition exists in the DVMRe.
0150-0193G 87 DVMRe Triplex
9 RS232 Remote Control Protocol
The unit supports two different communication types:
Byte 1 and 2 are header bytes.
Byte 3 contains the code for a specific front
panel button.
The different buttons and their corresponding
codes are as follows.
No Button Pressed 0
Record 1
Play 2
Stop 3
Alarm 4
Freeze 5
Zoom 6
Sequence 7
Reserved 8
Camera 1 9
Camera 2 10
Camera 3 11
Camera 4 12
Camera 5 13
Camera 6 14
Camera 7 15
Camera 8 16
Camera 9 17
Camera 10 18
Camera 11 19
Camera 12 20
Camera 13 21
Camera 14 22
Camera 15 23
Camera 16 24
Reserved 25 - 40
Menu 41
Enter 42
Reserved 43
Macro 44
Reserved 45-49
Monitor B 50
Reserved 51-63
Left Arrow 64
Right Arrow 65
Up Arrow 66
Down Arrow 67
Reserved 68-74
Alarm and Sequence 75
*Alarm and Camera 1 76
*Alarm and Camera 2 77
*Alarm and Camera 3 78
*Alarm and Camera 4 79
*Alarm and Camera 5 80
*Alarm and Camera 6 81
*Alarm and Camera 7 82
*Alarm and Camera 8 83
*Alarm and Camera 9 84
*Alarm and Camera 10 85
*Alarm and Camera 11 86
*Alarm and Camera 12 87
*Alarm and Camera 13 88
*Alarm and Camera 14 89
*Alarm and Camera 15 90
*Alarm and Camera 16 91
Reserved 92-110
Search 111
Frame Reverse 112
Frame Forward 113
Play Reverse 114
Stop 115
Play Forward 116
Monitor A 130
2 Way Multiscreen 131
4 Way Multiscreen 132
6 Way Multiscreen 133
7 Way Multiscreen 134
9 Way Multiscreen 135
10 Way Multiscreen 136
13 Way Multiscreen 137
16 Way Multiscreen 138
*Must send a “No Button Pressed” command
immediately following any of these
commands.
0150-0193G 88 DVMRe Triplex
9.2 Configuration and
Status
i) Data structure
Byte 1: 0xFF
Byte 2: Command Type
0xAA: (SET) Update DVMRe with data.
0xBB: (GET) Extract data from DVMRe.
Byte 3: Data Length (n)
Byte 4: Data Type
0x61: Restart DVMRe
0xFE: Send configuration data to DVMRe
0x09: Read Alarm History from DVMRe
0xFF: Read configuration and status data
from DVMRe
Byte 5: Data byte 1
Byte 6: Data byte 2
:
:
Byte x: Data byte n
ii) Sending data to the DVMRe
a) Restart DVMRe Triplex
This command will restart the DVMRe Triplex.
Byte 1: 0xFF
Byte 2: 0xAA
Byte 3: 0
Byte 4: 0x61
b) Send data to DVMRe Triplex
Configuration data can be sent to the DVMRe
Triplex, to change the way it operates. The
data is arranged in the form of 16 byte blocks,
numbered from 1 to 213. Blocks 182, 183 and
185 are status blocks, and hence cannot be
written to. For details about the contents of
each block, contact GE-Interlogix and request
the Block Data Structure for the DVMRe
Triplex.
After sending a block or series of blocks, block
number 255 must be updated to signal the end of
the configuration session. All data bytes for block
255 must be set to 0.
iii) Requesting data from the DVMRe
When a message of type 0xBB is sent to the
DVMRe Triplex, it will respond by sending 16
bytes of requested data.
a) Read Alarm History List
Byte 1: 0xFF
Byte 2: 0xBB
Byte 3: 0
Byte 4: 0x09
When the "Read Alarm History List" message is
received by the DVMRe Triplex, it responds by
sending a start byte 0xFF, followed by ASCII
strings for every alarm event in its alarm history
list, and a stop byte, 0xFF. Each string is
formatted as follows:
dd.bmm/ddbhh:mm:ssbaa<CR><LF>
dd: index number (00 - 99)
b: space character
mm: month (01-12)
dd: day (01-31)
hh: hours (00-23)
mm: minutes (00-59)
ss: seconds (00-59)
aa: alarm number (01-16)
<CR> Carriage return (0x0D)
<LF> Line feed (0x0A)
Example: 03. 11/27 22:48:58 15
b) Read data from DVMRe Triplex
Configuration and status data can be read from
the DVMRe Triplex. The data is arranged in the
form of 16 byte blocks, numbered from 1 to 213.
For details about the contents of each block,
contact GE-Interlogix and request the Block Data Structure for the DVMRe Triplex.
Byte 1: 0xFF
Byte 2: 0xBB
Byte 3: 1
Byte 4: 0xFF
Byte 5: Block Number 1-213 or 255 if all
blocks are requested.
The DVMRe Triplex responds to the “Read data”
request by sending all the requested data bytes
consecutively, without any start or stop bytes.
A total of either 16 bytes or 3408 bytes will be
transmitted, depending on whether a single block
or all the blocks were requested.
0150-0193G 89 DVMRe Triplex
10 Macro Tables
Photo copy this page and use it to keep a record of the programmed macro functions.
10.1 Macro Functions Table
Macro
Number
1
2
3
4
5
6
7
8
9
10
Description
11
12
13
14
15
16
Function +
Sequence
0150-0193G 90 DVMRe Triplex
Daylight Savings Time: Sets clock ahead one hour in April, and back one hour in
October.
10.2 Scheduled Macro Table
Event Day Time Macro to Run
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
0150-0193G 91 DVMRe Triplex
11 Warranty and Service
11.1 Factory Service
Warning: Do not open the top cover or attempt to service the unit, as this may
expose you to dangerous voltages and other hazards. Programmer maintenance of
this unit is limited to external cleaning and inspection. Refer all servicing to qualified
personnel.
If the unit requires factory service, contact the dealer who supplied the unit to you for the correct
procedures on returning the unit to the factory or the nearest factory service center.
If the dealer is not available, contact the manufacturer of the unit as detailed below and request a
Return Material Authorization number (RMA). The unit’s serial number must be provided before a
RMA number can be issued. Units returned to the factory for service must have freight and insurance
prepaid, and must show the RMA number clearly on all shipping documents. The failure symptoms
must be clearly described by the operator and enclosed with the unit together with a copy of the
original suppliers invoice. Failure to comply with these instructions will delay service of the unit, and
may result in the unit not being accepted by the Repair Center.
Factory Address
GE Security
Attention: Repair Center
3050 Redhill ave
Costa Mesa, CA. 92626
United States of America
Telephone: 800-343-3358 (7:00 AM to 4:30 PM, Pacific Time)
In Oregon: 541-754-9133
Fax: 541-754-7162 (24 hours a day)
For warranty information, see the following page.
0150-0193G 92 DVMRe Triplex
11.2 Warranty and Return Information
GE Security warrants all of its equipment for three years from the date of purchase. This warranty covers
any defects in materials and workmanship. Equipment failures that are due to improper installation,
modification, abuse, or acts of nature will not be covered by this warranty. The repair department will
evaluate all equipment returned for repair to determine warranty coverage. The Tech Support Manager
will resolve any questions that may arise during evaluation to make a final determination.
Note: The three-year warranty does not apply to the following products:
MobileView® and the monitor CRT, which carry a 12-month warranty from the date of purchase.
The warranty specifically covers any defects in material and workmanship and does not cover equipment
that has been abused, damaged, or modified.
For all warranty repairs, GE Security will cover all costs, including parts, labor, and shipping. Repaired
equipment will be returned via the same method of shipment in which it was received. If a customer
requests a faster return shipment, the difference will be charged.
For all non-warranty repairs, the customer will be billed for parts, labor, and shipping. Labor will be
billed in half-hour increments.
Note: Customers requesting an estimate prior to repair will be notified by phone. If they cannot be reached, they will be notified by
fax. If we are unable to reach the contact person for repair authorization after one phone attempt and two fax attempts, the
equipment will be returned without being repaired. We will hold equipment no longer than two weeks.
Advance Replacement Policy
When an advance replacement is required, we will send the customer replacement equipment from our
stock and receive the returned product in exchange. The received equipment will be evaluated and the
repair department will determine whether it is a warranty replacement. If it is non-warranty, see our repair
policy above for details. The following guidelines will be used for all advance replacements:
• Fewer than 45 days from purchase, GE Security will replace the product with new equipment.
• From 45 days to 1 year from purchase, GE Security will replace the product with refurbished
equipment.
• From 1 year to 3 years from purchase, the product must be sent in for repair. Advance
replacements will be sent for a fee of $100.
If you have questions about this policy, please contact the GE Security RMA Department at
800-469-1676.
0150-0193G 93 DVMRe Triplex
0150-0193G
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.