66" MIN.
Mounting
height from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-13/32
(Rear)
15-1/4
16
29-7/8
12"
MIN.
30 amp
Disconnect Switch
NEMA 14-30R
Wall Receptacle
SCA2001KSS – Above-the-Cooktop Advantium™ Oven
Dimensional Information (in inches)
IMPORTANT: PLEASE READ CAREFULLY. FOR PERSONAL
SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED
TO AVOID SEVERE OR FATAL SHOCK.
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
Specification Created 9/05
240435
Insure proper ground
exists before use.
Installation Information: This information is not intended to be used for
installing unit described. Before installing, consult installation instructions
packed with product/kit for current dimensional data.
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT, DEFORM,
OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT
USE WITH AN EXTENSION CORD.
NEMA 14-30R Wall Receptacle
SCA2001KSS – Above-the-Cooktop Advantium™ Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD E XHAUST DUCT. Read the following
carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4" x 10"
rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must
be used. Do not use less than a 6" diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align
exhaust with the space between studs, or wall should be prepared at the
time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
Filter Kit Accessory
Filter Kit
JX81A–Recirculating
Charcoal Filter Kit
To be used when
the Advantium oven
Grille
cannot be vented
to the outside.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4" x 10"
rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional
resistance to airflow and are equivalent to a section of straight duct
which is longer than their actual physical size. When calculating the
total duct length, add the equivalent length of all transitions and
adaptors plus the length of all straight duct sections. The chart below
shows the approximate feet of equivalent length of some typical ducts.
Duct
Rectangular-To-round
A.
Equivalent Feet
5 ft.
Transition Adaptor
Wall Cap 40 ft.
B.
90° Elbow 10 ft.
C.
45° Elbow 5 ft.
D.
90° Elbow 25 ft.
E.
45° Elbow 5 ft.
F.
Roof Cap 24 ft.
G.
Specification Created 9/05
240435
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.