GE SCA2001F Specification

GE SCA2001F Specification

TM

SCA2001F – Above-the-Cooktop AdvantiumOven

Dimensional Information (in inches)

NEMA 14-30R

 

 

Wall Receptacle

30"

 

 

 

66" MIN.

MIN.

Exhaust outlet

width

Mounting

required

connects to

height from

 

3-1/4" X 10" duct

floor

 

 

30 amp

 

 

 

 

Disconnect Switch

12"

MIN.

15-1/4

16-13/32 (Rear)

16

29-7/8

Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.

Specification Revised 7/04

IMPORTANT: PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.

Insure proper ground exists before use.

DO NOT, UNDER ANY

CIRCUMSTANCES, CUT, DEFORM,

OR REMOVE ANY OF THE PRONGS

FROM THE POWER CORD. DO NOT

USE WITH AN EXTENSION CORD.

NEMA 14-30R Wall Receptacle

Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.

Listed by

Underwriters

RLaboratories

For answers to your Monogram,® GE Profileor

GE appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center® service, 800.626.2000.

240434

TM

SCA2001F – Above-the-Cooktop AdvantiumOven

Hood Exhaust Duct

Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

EXHAUST CONNECTION:

The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct.

If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.

REAR EXHAUST:

If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

Filter Kit Accessory

Grille

Filter Kit

JX81A–Recirculating

Charcoal Filter Kit

To be used when the Advantium oven cannot be vented to the outside.

Specification Revised 7/04

MAXIMUM DUCT LENGTH:

For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed

140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.

Duct

Equivalent Feet

A. Rectangular-To-round

5 ft.

Transition Adaptor

 

B. Wall Cap

40 ft.

C. 90° Elbow

10 ft.

D. 45° Elbow

5 ft.

E. 90° Elbow

25 ft.

F. 45° Elbow

5 ft.

G. Roof Cap

24 ft.

Listed by

Underwriters

RLaboratories

For answers to your Monogram,® GE Profileor

GE appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center® service, 800.626.2000.

240434