SCA2000F – Above-the-Cooktop Advantium™ Oven
Dimensional Information (in inches)
NEMA 14-30R |
|
|
|
Wall Receptacle |
30" |
|
|
|
|
||
66" MIN. |
MIN. |
Exhaust outlet |
|
width |
|||
Mounting |
|||
required |
connects to |
||
height from |
|||
|
3-1/4" X 10" duct |
||
floor |
|
||
|
30 amp |
||
|
|
||
|
|
Disconnect Switch |
12"
MIN.
15-1/4
16-13/32 (Rear)
16
29-7/8
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
Specification Revised 7/04
IMPORTANT: PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.
Insure proper ground exists before use.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT, DEFORM,
OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT
USE WITH AN EXTENSION CORD.
NEMA 14-30R Wall Receptacle
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Listed by
Underwriters
RLaboratories
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
240432
TM
SCA2000F – Above-the-Cooktop Advantium™ Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Filter Kit Accessory
Grille
Filter Kit
JX81A–Recirculating
Charcoal Filter Kit
To be used when the Advantium oven cannot be vented to the outside.
Specification Revised 7/04
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct |
Equivalent Feet |
A. Rectangular-To-round |
5 ft. |
Transition Adaptor |
|
B. Wall Cap |
40 ft. |
C. 90° Elbow |
10 ft. |
D. 45° Elbow |
5 ft. |
E. 90° Elbow |
25 ft. |
F. 45° Elbow |
5 ft. |
G. Roof Cap |
24 ft. |