GE SCA2000BAA Specification

GE SCA2000BAA Specification

SCA2000BAA - Above-the-Cooktop AdvantiumOven

Dimensional Information (in inches)

Installation Requirements:

66" MIN.

30"

 

Mounting

 

MIN.

 

height

 

width

 

from

Exhaust outlet

required

floor

connects to

 

 

 

3-1/4" X 10" duct

12"

MAX.

14-13/16

16-3/32

20-1/2"

15-19/32

Door open

 

Electrical Requirements:

Product rating is 240/208 volts AC, 60 Hertz, 30 amps and 6.5 kilowatts. This product must be connected to an individual properly grounded branch circuit, protected by circuit breakers or time delay fuses. Wire size must conform to the requirements of the National Electric Code or the prevailing local code for kilowatt rating. The outlet box should be located in the cabinet above the oven. The supply circuit and outlet box should be installed by a qualified electrician and conform to all prevailing electrical codes. The wall outlet receptacle recommended for this appliance is NEMA#14-30R and accepts the four prong grounded plug of this appliance.

1.A minimum of 30” between the cabinets is required for the installation. If the space between the cabinets is than 30”, a Filler Panel Kit may be used to fill the gap between the oven and the cabinets. Your Owner’s Manual contains the kit number for your model.

2.Make sure the bottom edge of the cabinet that will be above the oven will be at least 66” from the floor and 30” from the cooking surface.

3.For easier access to change the hood and range lamps, the bottom of the oven should be at least 2” above the range backsplash.

4.If you are going to vent your oven to the outside, see exhaust duct preparation instructions.

5.When installing the oven beneath smooth, flat cabinets, be careful to follow the instructions on the top cabinet template for power cord clearance.

6.For best installation results, we recommend a maximum cabinet depth of 12”.

Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.

WARNING - PLEASE READ CAREFULLY.

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.

Insure proper ground

NEMA 14-30R

Wall Receptacle

exists before use.

 

DO NOT UNDER ANY CIRCUMSTANCES, CUT, DEFORM, OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.

For answers to your Monogram,®

GE Profile Performance Series,

GE Profileor GE appliance questions, call

GE Answer Center® service, 800.626.2000.

Specification Revised 10/00

Listed by Underwriters

R Laboratories

SCA2000BAA - Above-the-Cooktop AdvantiumOven

Hood Exhaust Duct

Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

EXHAUST CONNECTION:

The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.

If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct.

REAR EXHAUST:

If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

Filter Kit Accessory

Filter Kit

JX81A–Recirculating Charcoal Filter Kit

To be used when the Advantium oven

Grille

 

cannot be vented

 

to the outside.

MAXIMUM DUCT LENGTH:

For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed 140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.

Duct

Equivalent

 

 

 

A.

Rectangular-To-Round

5 Ft.

 

Transition Adaptor

 

B.

Wall Cap

40 Ft.

 

 

 

C.

90° Elbow

10 Ft.

 

 

 

D.

45° Elbow

5 Ft.

E.

90° Elbow

25 Ft.

 

 

 

F.

45° Elbow

5 Ft.

G.

Roof Cap

24 Ft.

For answers to your Monogram,®

GE Profile Performance Series,

GE Profileor GE appliance questions, call

GE Answer Center® service, 800.626.2000.

Listed by

Underwriters

R Laboratories

Specification Revised 10/00