SCA1001KSS – Advantium® 120 Above-the-Cooktop Oven

Dimensional Information (in inches)

66" MIN. Mounting height from floor

30"

 

MIN.

 

width

Exhaust outlet

required

connects to

 

 

3-1/4" X 10" duct

12"

MIN.

15-3/8

16-13/32 (Rear)

16

29-7/8

Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.

Specification Revised 9/05

Important: Please read carefully. For personal safety, this appliance must be properly grounded to avoid severe or fatal shock.

Do not, under any circumstances, cut, deform, or remove any of the prongs from the power cord. Do not use with an extension cord.

Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.

Listed by

Underwriters

RLaboratories

For answers to your Monogram,® GE Profileor

GE® appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center® service, 800.626.2000.

240437

TM

SCA1001KSS – Advantium® 120 Above-the-Cooktop Oven

Hood Exhaust Duct

Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

EXHAUST CONNECTION:

The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.

If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct.

REAR EXHAUST:

If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

Filter Kit Accessory

Grille

Filter Kit

JX81A–Recirculating

Charcoal Filter Kit

To be used when the Advantium oven cannot be vented to the outside.

Specification Revised 9/05

MAXIMUM DUCT LENGTH:

For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed

140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.

Duct

Equivalent

A. Rectangular-To-Round

5

Ft.

Transition Adaptor

 

 

B. Wall Cap

40

Ft.

C. 90° Elbow

10

Ft.

D. 45° Elbow

5

Ft.

E. 90° Elbow

25

Ft.

F. 45° Elbow

5

Ft.

G. Roof Cap

24

Ft.

For answers to your Monogram,® GE Profileor

GE® appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center® service, 800.626.2000.

240437