GE SCA1001HSS User Manual

TM
SCA1001HSS – Advantium® 120 Above-the-Cooktop Oven
Mounting
height
from floor
30"
MIN.
width
required
Exhaust outle
t
connects to
3-1/4" X 10" duct
16-13/32
(Rear)
15-3/8
16
29-7/8
12"
MIN.
R
Dimensional Information (in inches)
Important : Please read carefully. For personal safety, this appliance must
be properly grounded to avoid severe or fatal shock.
Do not, under any circumstances, cut, deform, or remove any of the prongs from the power cord. Do not use with an extension cord.
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
Specification Revised 4/04
240436
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
TM
SCA1001HSS – Advantium® 120 Above-the-Cooktop Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Filter Kit Accessory
Filter Kit
JX81A–Recirculating Charcoal Filter Kit
To be used when the Advantium oven
Grille
cannot be vented to the outside.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct Equivalent
A. Rectangular-To-Round 5 Ft.
Transition Adaptor
B. Wall Cap 40 Ft.
C. 90° Elbow 10 Ft.
D. 45° Elbow 5 Ft.
E. 90° Elbow 25 Ft.
F. 45° Elbow 5 Ft.
G. Roof Cap 24 Ft.
Specification Revised 4/04
240436
For answers to your Monogram GE® appliance questions, visit our website at GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
,® GE Profile™ or
Loading...
+ 1 hidden pages