Specification Revised 7/02
SCA1001DSS – Advantium™120 Oven
Dimensional Information (in inches)
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-19/32
15-3/8
15-21/32
12"
MAX.
1. A minimum of 30" between the cabinets is required for the installation. If
the space between the cabinets is greater than 30", a Filler Panel Kit may
be used to fill the gap between the oven and the cabinets. Your Owner’s
Manual contains the kit number for your model.
2. Make sure the bottom edge of the cabinet that will be above the oven will
be at least 66" from the floor and 30" from the cooking surface.
3. For easier access to change the hood and range lamps, the bottom of the
oven should be at least 2" above the range backsplash.
4. If you are going to vent your oven to the outside, see exhaust duct
preparation instructions.
5. When installing the oven beneath smooth, flat cabinets, be careful to follow
the instructions on the top cabinet template for power cord clearance.
6. For best installation results, we recommend a maximum cabinet depth of 12".
Installation Information: This information is not intended to be used for installing
unit described. Before installing, consult installation instructions packed with
product/kit for current dimensional data.
Electrical Requirements:
Product rating is 120 volts AC, 60 Hertz, 15 amps and 1800 watts.
Product plugs into any standard 120-volt outlet.
Installation Requirements:
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center®service, 800.626.2000.
Specification Revised 7/02
SCA1001DSS – Advantium™120 Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4” x 10”
rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used.
Do not use less than a 6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust
with the space between studs, or wall should be prepared at the time it is constructed
by leaving enough space between the wall studs to accommodate exhaust.
Grille
Filter Kit Accessory
Filter Kit
JX81A–Recirculating
Charcoal Filter Kit
To be used when
the Advantium oven
cannot be vented
to the outside.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or
6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance
to airflow and are equivalent to a section of straight duct which is longer than their
actual physical size. When calculating the total duct length, add the equivalent length
of all transitions and adaptors plus the length of all straight duct sections. The chart
below shows the approximate feet of equivalent length of some typical ducts.
Duct Equivalent Feet
A. Rectangular-To-round 5 ft.
Transition Adaptor
B. Wall Cap 40 ft.
C.90° Elbow 10 ft.
D.45° Elbow 5 ft.
E.90° Elbow 25 ft.
F.45° Elbow 5 ft.
G. Roof Cap 24 ft.
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center®service, 800.626.2000.