SCA1000HBB/CC/WW – Advantium® 120 Above-the-Cooktop Oven
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outle
t
connects to
3-1/4" X 10" duct
16-13/32
(Rear)
15-3/8
16
29-7/8
12"
MIN.
Dimensional Information (in inches)
Important: Please read carefully. For personal safety, this
appliance
fatal shock.
Do not, under any circumstances, cut, deform, or remove any
of the prongs from the power cord. Do not use with an
extension cord.
Installation Information: This information is not intended to
be used for installing unit described. Before installing, consult
installation instructions packed with product/kit for current
dimensional data.
must be properly grounded to avoid severe or
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
Specification Revised 4/04
240438
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
SCA1000HBB/CC/WW – Advantium® 120 Above-the-Cooktop Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4” x 10”
rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used.
Do not use less than a 6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust
with the space between studs, or wall should be prepared at the time it is constructed
by leaving enough space between the wall studs to accommodate exhaust.
Filter Kit Accessory
Filter Kit
JX81A–Recirculating
Charcoal Filter Kit
To be used when
the Advantium oven
Grille
cannot be vented
to the outside.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4” x 10”
rectangular or 6” diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional
resistance to airflow and are equivalent to a section of straight duct
which is longer than their actual physical size. When calculating the
total duct length, add the equivalent length of all transitions and adaptors
plus the length of all straight duct sections. The chart below shows the
approximate feet of equivalent length of some typical ducts.
Duct Equivalent
A. Rectangular-To-Round 5 Ft.
Transition Adaptor
B. Wall Cap 40 Ft.
C. 90° Elbow 10 Ft.
D. 45° Elbow 5 Ft.
E. 90° Elbow 25 Ft.
F. 45° Elbow 5 Ft.
G. Roof Cap 24 Ft.
Specification Revised 4/04
240438
For answers to your Monogram
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
,® GE Profile™ or