TM
SCA1000HBB/CC/WW – Advantium® 120 Above-the-Cooktop Oven
Dimensional Information (in inches)
66" MIN. |
30" |
|
|
Mounting |
|
||
MIN. |
|
||
height |
|
||
width |
|
||
from |
Exhaust outlet |
||
required |
|||
floor |
connects to |
||
|
|||
|
|
3-1/4" X 10" duct |
12"
MIN.
15-3/8
16-13/32 (Rear)
16
29-7/8
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
Specification Revised 4/04
Important: Please read carefully. For personal safety, this appliance must be properly grounded to avoid severe or fatal shock.
Do not, under any circumstances, cut, deform, or remove any of the prongs from the power cord. Do not use with an extension cord.
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Listed by
Underwriters
RLaboratories
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
240438
TM
SCA1000HBB/CC/WW – Advantium® 120 Above-the-Cooktop Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Filter Kit Accessory
Grille
Filter Kit
JX81A–Recirculating
Charcoal Filter Kit
To be used when the Advantium oven cannot be vented to the outside.
Specification Revised 4/04
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct |
Equivalent |
|
A. Rectangular-To-Round |
5 |
Ft. |
Transition Adaptor |
|
|
B. Wall Cap |
40 |
Ft. |
C. 90° Elbow |
10 |
Ft. |
D. 45° Elbow |
5 |
Ft. |
E. 90° Elbow |
25 |
Ft. |
F. 45° Elbow |
5 |
Ft. |
G. Roof Cap |
24 |
Ft. |
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.