SCA1000DBB/CC/WW – Advantium™ 120 Oven
Dimensional Information (in inches)
66" MIN. |
30" |
|
|
Mounting |
|
||
MIN. |
|
||
height |
|
||
width |
|
||
from |
Exhaust outlet |
||
required |
|||
floor |
connects to |
||
|
|||
|
|
3-1/4" X 10" duct |
12"
MAX.
15-3/8
16-19/32
15-21/32
Electrical Requirements:
Product rating is 120 volts AC, 60 Hertz, 15 amps and 1800 watts. Product plugs into any standard 120-volt outlet.
Specification Revised 7/02
Installation Requirements:
1.A minimum of 30" between the cabinets is required for the installation. If the space between the cabinets is greater than 30", a Filler Panel Kit may be used to fill the gap between the oven and the cabinets. Your Owner’s Manual contains the kit number for your model.
2.Make sure the bottom edge of the cabinet that will be above the oven will be at least 66" from the floor and 30" from the cooking surface.
3.For easier access to change the hood and range lamps, the bottom of the oven should be at least 2" above the range backsplash.
4.If you are going to vent your oven to the outside, see exhaust duct preparation instructions.
5.When installing the oven beneath smooth, flat cabinets, be careful to follow the instructions on the top cabinet template for power cord clearance.
6.For best installation results, we recommend a maximum cabinet depth of 12".
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Listed by
Underwriters
R Laboratories
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
TM
SCA1000DBB/CC/WW – Advantium™ 120 Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Filter Kit Accessory
Grille
Filter Kit
JX81A–Recirculating Charcoal Filter Kit
To be used when the Advantium oven cannot be vented to the outside.
Specification Revised 7/02
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct |
Equivalent Feet |
|
A. Rectangular-To-round |
5 ft. |
|
|
Transition Adaptor |
|
B. Wall Cap |
40 ft. |
|
|
|
|
C. |
90° Elbow |
10 ft. |
|
|
|
D. 45° Elbow |
5 ft. |
|
|
|
|
E. |
90° Elbow |
25 ft. |
|
|
|
F. |
45° Elbow |
5 ft. |
|
|
|
G. Roof Cap |
24 ft. |
|
|
|
|
|
Listed by |
|
Underwriters |
R |
Laboratories |
For answers to your Monogram,® GE Profile™ or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.