GE Rightrax LT Operating Manual

GE
Sensing & Inspection Technologies
Rightrax LT Specications
Online Corrosion Monitoring System
M2 Sensor
Sensor type Nominal frequency Operating mode Typical Measuring
Range Measurement area
Couplant Mounting Cabling 1.5 m (4.9 ft) with Lemo or BNC connector
Housing Ingress rating Dimensions Main housing: 83 x 70 x 35 mm (3.27 x 2.76 x 1.38”)
Weight
Certication
Temperature range
14-element linear array
Minimum measurable thickness depends on internal wall damage mechanism. 200 mm x 12 mm (7.87 x 0.47”) Acoustic Tape
Permanent xing by acoustic tape and epoxy putty
Extension cable up to a maximum of 70 m (230 ft) Stainless Steel 316L IP56 equivalent
Flexible strip: 244 x 55 mm (9.61 x 2.17”)
0.50 kg (1.1 lb) ATEX Zone 2
-40°C to 120°C (-40°F to 248°F)
Rightrax LT System
Thickness repeatability ± 0.1 mm
Thickness accuracy Accuracy depends on knowing the substrate material sound velocity. Calibration standards or material
Thickness resolution ­single reading Total number of sensors per attached data logger Total number of data loggers per line driver Maximum total number of sensor extension cable per system
(0.0039”)
± 0.01 mm (0.0039”)
10
2 Each driven by a 10-way multi-core cable with a maximum length of 260 m (853 ft)
450 m (1476 ft)
The repeatability of the thickness reading through the complete system is the smallest change that can be reliably detected.
specications of the material are required for accurate results. This accuracy applies for uniform surfaces. Highly
localized pitting may not be detected.
An individual sensor can have up to 70 meters of extension cable, but the total length of extension cable for the whole system cannot exceed 450 m (1476 ft).
www.gesensinginspection.com