GE
Sensing & Inspection Technologies
Rightrax LT Specications
Online Corrosion Monitoring System
M2 Sensor
Sensor type
Nominal frequency
Operating mode
Typical Measuring
Range
Measurement area
Couplant
Mounting
Cabling 1.5 m (4.9 ft) with Lemo or BNC connector
Housing
Ingress rating
Dimensions Main housing: 83 x 70 x 35 mm (3.27 x 2.76 x 1.38”)
Weight
Certication
Temperature range
14-element linear array
8.0 MHz
Pulse Echo
5 - 100 mm (0.196 - 3.9”) on smooth parallel surfaces.
Minimum measurable thickness depends on internal wall damage mechanism.
200 mm x 12 mm (7.87 x 0.47”)
Acoustic Tape
Permanent xing by acoustic tape and epoxy putty
Extension cable up to a maximum of 70 m (230 ft)
Stainless Steel 316L
IP56 equivalent
Flexible strip: 244 x 55 mm (9.61 x 2.17”)
0.50 kg (1.1 lb)
ATEX Zone 2
-40°C to 120°C (-40°F to 248°F)
Rightrax LT System
Thickness repeatability ± 0.1 mm
Thickness accuracy Accuracy depends on knowing the substrate material sound velocity. Calibration standards or material
Thickness resolution single reading
Total number of sensors
per attached data logger
Total number of data
loggers per line driver
Maximum total number
of sensor extension
cable per system
(0.0039”)
± 0.01 mm
(0.0039”)
10
2 Each driven by a 10-way multi-core cable with a maximum length of 260 m (853 ft)
450 m (1476 ft)
The repeatability of the thickness reading through the complete system is the smallest change that can be
reliably detected.
specications of the material are required for accurate results. This accuracy applies for uniform surfaces. Highly
localized pitting may not be detected.
An individual sensor can have up to 70 meters of extension cable, but the total length of extension cable for the
whole system cannot exceed 450 m (1476 ft).
www.gesensinginspection.com
GEIT-20211EN (05/10)