GE RHM 04 Overwiew And Specifications

Page 1
GE
Measurement & Control
RHM 04
Versatile Coriolis Mass Flowmeter with Fast Response Times for Very High Pressure Applications
The RHM 04 can measure ow rates up to 10 kg/min (22 lb/min) with extremely fast response times and excellent repeatability. A very high pressure version up to 1067 bar is also available, manufactured by GE’s Rheonik mass owmeter experts.
Applications
• Batching • Injections • Filling
Features
• Available as very high pressure version up to 1067
bar
• Response times of 30 ms and better
• Flow uncertainty down to 0.10%
• Repeatability better than 0.05%
• Unique torsion oscillator
• Typical measuring ranges from 0.1 to 10 kg/min
• Minimal ows as low as 50 g/min
• Customization possible
• Extra compact design with minimal space requirement
• Hazardous Area Approvals (ATEX, CSA, ...)
Advantages
• Torsion oscillator design assures most stable and basically drift free measurement and increased signal to noise ratio
• Not sensitive to changes in pressure
• Longest life time and increased safety (low stress in welds and increased wall thickness against abrasion)
• No moving parts, practically no maintenance
• Removable connection manifold available
g
Page 2
General Dimensions RHM 04
PM0/SM0 (parallel/serial, manifold construction)
Type removable manifold with PTFE seals and ange connection H1 = 173 mm (6.79 in) H2 = 189 mm (7.44 in)
PM0/SM0/PH0 (parallel/serial, manifold construction with thread connection)
Process Connection Face to face length (L) Order Code
mm in
Standard Flange DIN DN15/PN40 220 8.66 D1
Flange DIN DN15/PN100 220 8.66 D2
Flange ANSI ½" 150# RF/SF 220 8.66 A1
Flange ANSI ½" 300# RF/SF 220 8.66 A2
Flange ANSI ½'' 600# RF/SF 220 8.66 A3
Flange ANSI ½" 1500# RF/SF 300 11.81 A6
Flange ANSI ½'' 1500# RTJ 300 11.81 R1
Optional Flange DIN DN15 / PN 160 220 8.66 D3
Flange JIS RF 10k 15A (1/2") 220 8.66 J1
Flange JIS RF 20k 15A (1/2") 220 8.66 J2
Process Connection Face to face length (L) Order Code
mm in
PM0/SM0 Standard
PH0 Standard
Female Thread G ¼" 50 1.97 G1
Female Thread ¼" NPT 50 1.97 N1
Female Thread G ¼" 70 2.76 G1
Female Thread ¼" NPT 70 2.76 N1
Autoclave 3/8" MP (9/16-18 UNF female thread)
70 2.76 P2
Type removable manifold with PTFE seals and thread connection
PM0/SM0
H1 = 173 mm (6.79 in) H2 = 189 mm (7.44 in)
PH0 (high pressure manifold construction)
H1 = 184 mm (7.24 in) H2 = 204 mm (8.03 in)
PHH (parallel, very high pressure manifold construction)
Type parallel, very high pressure manifold with PTFE seals and thread connection (orientation upwards) H1 = 184 mm (7.24 in) A = 28 mm (1.10 in) D = 6.5 mm (0.26 in) L1 = 160 mm (6.30 in)
Process Connection Overall Height (H) Order Code
Standard Autoclave 3/8" MP (9/16-18
UNF female thread)
mm in
234 9.21 P2
A1 = 130 mm (5.12 in) B1 = 25 mm (0.98 in) Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in) A2 = 145 mm (5.71 in) B2 = 40 mm (1.57 in) W = 0 mm for Temperature Range T1 and TA W = 100 mm (3.94 in) for Temperature Range T2
For weights and packaging dimensions please see last page of this section.
2
Page 3
General Dimensions RHM 04
PF0 (parallel, sealless construction with ange connection)
Type parallel, welded measuring loops without seals and ange connection
PFT (parallel, sealless construction with thread connection)
Process Connection Face to face length (L) Order Code
mm in
Standard Flange DIN DN15/PN40 220 8.66 D1
Flange DIN DN15/PN100 220 8.66 D2
Flange ANSI ½" 150# RF/SF 220 8.66 A1
Flange ANSI ½" 300# RF/SF 220 8.66 A2
Flange ANSI ½'' 600# RF/SF 220 8.66 A3
Flange ANSI ½" 1500# RF/SF 300 11.81 A6
Flange ANSI ½'' 1500# RTJ 300 11.81 R1
Optional Flange DIN DN15 / PN160 220 8.66 D3
Flange DIN DN25 / PN160 260 10.24 D4
Flange ANSI ½" 2500# RF/SF 300 11.81 A8
Flange JIS RF 10k 15A (1/2") 220 8.66 J1
Flange JIS RF 20k 15A (1/2") 220 8.66 J2
Grayloc Hub 1 GR4 (1") 300 11.81 H3
Process Connection Face to face length (L) Order Code
mm in
Standard Female Thread G ¼" 220 8.66 G1
Female Thread ¼" NPT 220 8.66 N1
Swagelok ¼" tube inlet (SS­400-1-4W)
300 11.81 W1
Type parallel, welded measuring loops without seals and thread connection
A1 = 130 mm (5.12 in) B1 = 25 mm (0.98 in) Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in) A2 = 145 mm (5.71 in) B2 = 40 mm (1.57 in) W = 0 mm for Temperature Range T1 and TA H1 = 173 mm (6.79 in) W = 100 mm (3.94 in) for Temperature Range T2, T3 and T4 H2 = 205 mm (8.07 in)
For weights and packaging dimensions please see last page of this section.
3
Page 4
General Dimensions RHM 04
SF0 (serial, sealless construction without dead spaces) (*)
Type single path, welded measuring loops without seals and sanitary connection H2 = 184 mm (7.24 in)
Process Connection Face to face length (L) Order Code
mm in
Standard Sanitary ½" Triclamp, DIN
32676
Sanitary NW10, DIN 11851 220 8.66 S2
Process Connection Face to face length (L) Order Code
Standard Flange DIN DN15/PN40 220 8.66 D1
Flange ANSI ½" 150# RF/SF 220 8.66 A1
Flange ANSI ½" 300# RF/SF 220 8.66 A2
Optional Flange ANSI ½'' 150# RTJ 220 8.66 R3
220 8.66 S1
mm in
Type single path, welded measuring loops without seals and ange connection H2 = 205 mm (8.07 in)
A1 = 130 mm (5.12 in) B1 = 25 mm (0.98 in) Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in) A2 = 145 mm (5.71 in) B2 = 40 mm (1.57 in) W = 0 mm for Temperature Range T1 and TA H1 = 173 mm (6.79 in) W = 100 mm (3.94 in) for Temperature Range T2, T3 and T4
(*) SF0 construction contains brazed joints (brazing material B-Ni82CrSiBFe-970/1000) which are not as corrosion resistant as the piping material 1.4571 (316Ti).
Weight in standard manifold construction with female threads: approx. 2.5 kg (5.5 lb)
Weight in standard sealless construction and 150# anges: approx. 3.5 kg (7.7 lb)
Shipping in carton box approx. 60 x 41 x 32 cm (24 x 16 x 13 in), gross weight with sealless construction, 150# standard anges and RHE 08 approx. 10 kg (22 lb)
Finish type of our ANSI anges corresponds to SF (AARH 125 up to 250 μin, Ra 3.2 up to 6.3 μm)
For customization with regard to face to face length and special ttings, please consult your local agent
Please note that larger diameter process connections are always possible
4
Page 5
Pressure Rating RHM 04
The maximum pressure (pmax) of a sensor is determined by its weakest part. The weakest part can be the measuring loops (pmax indicated below) or the construction type (pmax indicated in the Basic Order Code section, last page) or the selected anges / ttings (for pmax please see respective standard).
pmax of P1 measuring loops, standard M0 standard material - 1.4539 (904 L) OD x WT 4.5 x 0.3 mm (0.18 x 0.012 in)
bar °C psi °F
170 50 2466 122
150 120 2176 248
120 210 1740 410
100 350 1450 662
pmax of P2 measuring loops M0 standard material - 1.4539 (904 L) OD x WT 4.5 x 0.5 mm (0.18 x 0.02 in)
bar °C psi °F
295 50 4279 122
250 120 3626 248
200 210 2901 410
170 350 2466 662
pmax of P1 measuring loops M3 optional material - 2.4602 (Alloy C22) OD x WT 4.5 x 0.3 mm (0.18 x 0.012 in)
bar °C psi °F
215 50 3118 122
190 120 2756 248
153 210 2219 410
128 350 1856 662
pmax of PH measuring loops HP optional material - HP160 OD x WT 4.5 x 0.9 mm (0.18 x 0.035 in)
bar °C psi °F
1067 20 15476 68
900 50 13053 122
870 120 12618 248
pmax of P1 measuring loops* M1 optional material - 1.4571 (316 Ti) OD x WT 4.5 x 0.3 mm (0.18 x 0.012 in)
bar °C psi °F
156 50 2263 122
*Only for T3 temperature rating
5
Page 6
Performance RHM 04
Max Flow Rate Qmax and Qnom (*) = 10 kg/min (22 lb/min)
Standard Models
Flow Rate Uncertainty
kg/min lb/min in % of reading
10.0 22.05 0.20
7.0 15.43 0.20
4.0 8.82 0.20
0.5 1.10 0.20
0.2 0.44 0.50
Goldline Models (**) - selected sensors
Flow Rate Uncertainty
kg/min lb/min in % of reading
10.0 22.05 0.10
7.0 15.43 0.10
4.0 8.82 0.10
1.0 2.20 0.10
0.5 1.10 0.12
Uncertainty % DP (bar)
Flow Rate kg/min
Uncertainty % DP (bar)
Low Flow Models (**) - selected sensors
Flow Rate Uncertainty
kg/min lb/min in % of reading
4.0 8.82 0.20
2.0 4.41 0.20
1.0 2.20 0.20
0.2 0.44 0.20
0.1 0.22 0.60
Repeatability
Better ± 0.1% of rate, Goldline 0.05%
Temperature
Better ± 1°C
(*) Nominal ow Qnom refers to roughly 8 - 10 m/s (33 ft/s) velocity in measuring loops for best performance. (**) Selected sensors are only available in combination with temperature options T1, TA, standard material and pressure range.
• Serial/single path versions oer the same accuracy at half the ow (Qmax serial version = 5 kg/min).
• No relevant pressure eect due to torsional oscillation and semi-circle (non-deforming) measurement section.
6
Flow Rate kg/min
Uncertainty % DP (bar)
Flow Rate kg/min
• Uncertainty of reading (incl. zero drift) indications refer to reference conditions H
O, 18-24°C (66 - 76°F), 1 - 3
2
bar (15 – 45 psi) and installation according to eld manual.
• Pressure drop indications refer to H2O, with parallel measuring loops type P1 and standard manifold block connections.
• For calibration to customer range and / or with improved uncertainty, please consult factory.
Page 7
General Specications RHM 04
Temperature Range
• NT Models from -20 to +120°C (-4 to +248°F)
• ET Models from -45 to +120°C (-49 to +248°F)
• ET2 Models from -45 to +210°C (-49 to +410°F)
• ET1 Models from -196 to +50°C (-320 to +122°F)
• HT Models from 0 to 350°C (+32 to +662°F) (Heating for housing optional, please consult your local agent)
Electrical Connection
• Junction box Aluminium coated (standard). Junction box in SS 316Ti optional
• Cable entry M25 x 1.5. Optional cable entries M20 x 1.5, 1/2” NPT or 3/4” NPT
• Max cable length between RHM and RHE is 100m (330 ft). 200m (660 ft) only with factory approval
Material of Wetted Parts
• 1.4539 / SS 904 L / UNS N08904 (standard measuring loops material)
• 1.4571 / SS 316 Ti / UNS S31635 (standard connection part material, optional measuring loops material)
• 2.4602 / Alloy C22 / UNS N06022
• HP 160
• Others on request
Sensor Enclosure/Housing
• Stainless Steel 1.4301 / SS 304, optional in 1.4571 / SS 316Ti. Others on request
• Protection Class IP 65. Optional IP 66 / NEMA 4x
Approvals
• ATEX (CESI 02 ATEX 053 X) Ex II 1 G, EEx ia IIC T6-T1
• CSA USA-Canada, Class I, Div. 1, Groups A, B, C, D
• PED according to directive 97/23/EC Art.3 (3) Sound Engineering Practice (SEP)
• Others on request
7
Page 8
Basic Order Code RHM 04
Sensor Size
Temperature Range
T1 NT from -20°C to +120°C (standard) TA ET from -45°C to +120°C T2 ET2 Extended Temperature Range from -45°C to +210°C T3 ET1 Extended Temperature Range from -196°C to +50°C T4 HT High Temperature Range from 0°C to +350°C
Pressure Range of Measuring Loops @ 120°C
P1 pmax = 150 bar, M0 Material (standard) P2 pmax = 250 bar, M0 Material PH pmax = 870 bar, HP Material
Construction Type (pmax indications @ 120°C)
PM0 Parallel Measuring Loops with removable Manifold and PTFE Seals, pmax = 400 bar with thread connection, 214 bar with ange connection SM0 Serial Measuring Loops with removable Manifold and PTFE Seals pmax = 400 bar with thread connection, 214 bar with ange connection PF0 Parallel Measuring Loops Seal Less Version SF0 Serial Measuring Loops Seal Less Version, pmax = 42.9 bar PFT Parallel Measuring Loops Seal Less Version for Thread Connection, pmax = 530 bar PH0 Parallel Measuring Loops with High Pressure Manifold and PTFE Seals, pmax = 540 bar PHH Parallel Measuring Loops with Very High Pressure Manifold and PTFE Seals, pmax = 870 bar
Material of Wetted Parts
M0 Measuring Loops 1.4539 (904L), Manifold/Connection 1.4571 (316Ti) (standard) M1 Measuring Loops and Manifold/Connection 1.4571 (316Ti) M3 Measuring Loops and Connection Part 2.4602 (Alloy C22), Seal Less Construction Types only HP Measuring Loops HP 160; not with PF0, SF0, PFT Construction Type
Process Connection
D1 Flange DIN DN15/PN40 Form C D2 Flange DIN DN15/PN100 Form E A1 Flange ANSI ½” 150# RF/SF A2 Flange ANSI ½” 300# RF/SF A3 Flange ANSI ½’’ 600# RF/SF R1 Flange ANSI ½’’ 1500# RTJ A6 Flange ANSI ½” 1500# RF G1 Female Thread G ¼” N1 Female Thread ¼” NPT W1 Swagelok ¼” tube inlet (SS-400-1-4W) - valid for SS only S1 Sanitary ½” Triclamp, DIN 32676, pmax = 40 bar @ 120°C S2 Sanitary NW10, DIN 11851, pmax = 40 bar @ 120°C P2 Autoclave 3/8” MP (9/16-18 UNF female thread) Others on request
RHM 04 - - - -
www.ge-mcs.com
g
920-493A
© 2013 General Electric Company. All Rights Reserved. Specications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not aliated with GE.