GE RAVWPT14, RAVWPT8 Installation Instructions

Installation Instructions
A
B
for your new
Wall Plenum
Before you begin - Read these instructions completely and carefully. IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer – Be sure to leave these instructions with the Consumer. Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.
YOUR WALL PLENUM WILL ONLY WORK IF INSTALLED CORRECTLY. MAKE SURE TO INSTALL IT IN THE CORRECT ORIENTATION AS SHOWN IN THE ILLUSTRATIONS.
Select the proper plenum kit based on the wall thickness: RAVWPT8 adjusts for walls 5.5-8.0” thick or RAVWPT14 adjusts for walls 8-14.0” thick. For ease of installation, Grille Kit RAVAL2 should be installed at time of Wall Plenum Installation.
Parts Included
There are two parts to a Wall Plenum: Part A - Outside Plenum
Installed so grille attachment flanges are on the outside of the building and 45° drip ledge is at the bottom
Part B - Inside Plenum
Installed so the large opening on bottom and the 3/4” flanges are against the inside wall of the building.
Materials Needed (Field Supplied Parts)
Silicone Caulk (recommended)
Flashing
Shims
Header Material/Wall Studs
• 1” - 3” Screws to attach the plenum assembly to the wall studs.
• Grille Kit RAVAL2 (sold separately)
Large Opening
Outside Plenum
Inside Plenum
Installation Overview
Grille Kit RAVAL2 (not included)
Part A Outside Wall Plenum
RAVWPT8 – 5 1/2”- 8” D x 24 1/8” W x 30 3/8” H RAVWPT14 – 8” - 14” D x 24 1/8” W x 30 3/8” H
Exterior/ Outside Wall
Properly sized header is required for structural support. Proper caulking and flashing is required.
Part B Inside Wall Plenum
45° Drip Ledge
NOTE: The plenum has
a wax cardboard weather cover. Do not remove this cover until ready to install the grille (Kit # RAVAL2).
Properly square and level plenum.
Unit
GE is a trademark of the General Electric Company. Manufactured under trademark license.
95303004 31-30817 11-16 GEA
Installation Instructions
STEP 1 Measure, Cut, and Frame out the Outside Wall Plenum Opening
IMPORTANT: The dimension from the top of the sill (bottom framing of rough opening) to the platform surface
changes depending on what model is to be installed. See Table A to determine the proper dimension for a specific model.
NOTE: A minimum platform height of 8 inches is recommended to access drain connections.
Measure and mark on the inside of the external closet wall the plenum cutout dimensions as shown. Cut, frame, and square rough opening. The wall plenum has a 3/4” flange all the way around to cover the rough cut opening
9,000, 12,000, and 18,000 BTU/hr - Chassis Height 32”
The plenum cut out dimensions are 24-5/8” wide x 30-7/8” high. The top of the sill must be 3/4” from the platform surface the unit will sit on.
18,000 BTU/hr - Chassis Height 47”
The plenum cut out dimensions are 24-5/8” wide x 30-7/8” high. The top of the sill must be 1-1/2” from the platform surface the unit will sit on.
IMPORTANT: The wall plenum is not designed to carry
24-5/8”
structural loads. A proper header opening must be built into the rough opening. The plenum requires flashing, shim, and caulk for a weather-resistant installation.
It is the responsibility of the contractor to properly install the
30-7/8”
plenum and meet building code requirements.
Table A
Model Chassis Height Dimension from top of sill to
9,000, 12,000, and 18,000 BTU/ hr
18,000 BTU/hr 47 inches 1-1/2 inches
32 inches 3/4 inches
the top of the platform surface
the unit is sitting on
Sill (Bottom Framing)
Platform Surface
STEP 2 Install Grille Kit RAVAL2 (not included) on the Outside Plenum
NOTE: The Grille Kit RAVAL2 is best installed
onto the Outside Plenum (Part A) prior to the wall plenum being installed in the building. Grille installation is easier at this point, and it will help keep the wall plenum square during installation.
Attach grille with 4 screws
See Table A for proper dimension
Minimum 8” Platform Recommended
8”min.
Side View
If you are not installing the grille at this time be sure the plenum is square when installed in the opening.
NOTE: Refer to instructions included in the Grille Kit RAVAL2 for proper installation procedure.
(not included)
2
Grille
45° Drip Ledge
Louver
Wall Plenum
Part A
Installation Instructions
STEP 3 Plenum Installation
NOTES:
• A properly sized header and rough in framing must conform to all national and local building codes.
• Before caulking and permanent attachment, dry fit the outside plenum into the rough opening and check for fit, squareness and that the plenum is level.
• When securing the plenum into the opening drive screws into the vertical sides of the plenum only. Water may penatrate into framing if screws are driven into the bottom of the plenum. See Detail A below.
Proper Header*
Proper Flashing*
Proper Caulking*
Building Rough Opening
Outside
Wall
Grille mounted on the Outside Wall Plenum Half (Part A)
* Denote Field Supplied Parts
1. Install Outside Wall Plenum
Prior to the outside plenum being inserted into the rough opening for the final time, flashing should be installed and the plenum should be caulked along the flange on all four sides to provide a weather-resistant seal. With the plenum properly caulked, push the outside plenum into the rough opening until the flanges of the plenum are against the wall. Once installed, the outside plenum should be securely attached to the frame opening. Drive screws through the vertical sides only to secure the plenum (Detail A).
Caulk may need to be applied to the outside of the building along the plenum frame to insure a water tight seal.
A
Proper Flashing*
A
Detail A
All four corners
A
A
3
Loading...