GE RAVHW1, RAVHW2, RAVHW3 Installation Guide

TOOLS NEEDED
Adjustable wrench
Phillips head screwdriver
Brazing equipment
Piping solder or flux
B] Connect the tubing.
There are two options: [] Standard Connection or
[] By-Pass Connection.
Choose the appropriate connection for your installation requirements.
.4,CAUTION: Disconnect the electricalpower
supplg before installing.
Fll Placethe Heater the Vertical
Zoneline by locating the four holes in its side flanges over the four bolts on the top of the
Zoneline.
HL!dronic heater
bolts
Zoneline
F21 Attach Hydronic Heater to using
6 screws.
the the Zoneline
onto
,
Locating holes (_nd
bolts
I
Standard Connection Option Connect the 90°elbow to the upper outlet tube.
Connect the shut-off valve to the other end of the 90°elbow.
Shut-off valve
90° elbow
tube
FB1 By-Pass Connection Option
Connect the long two-bend tube to the lower inlet tube, turn it and connect it to the T-fitting inthe
outlet tube. Connect the shut-off valve to the other end of the T-fitting.
Shut-off valve
31-61420 I
07-07 JR
T-fitting
two-bend tube
Lower inlet
tube
Printed in Chino
Installation Instructions
14"1 Connect the from the
Hgdronic Heater to the three-pin connector
on the Zoneline.
three-pin
connector
U
Three-pin _\ connectors
I-'S1 Runand the !0" round duct the
Hgdronic Heater.
10" round
connect to
r61 Move the actuator switch to the OPENposition.
Actuator
rT1 Reconnect electrical power.
OUTILLAGE NECESSAIRE
CI__ molette Equipement de brasage
Tourneviscruciforme Brasure ou flux de tugauterie
B] Raccordez la tugauterie.
IIexiste deuxoptions: [] Raccordementnormalou
[] Raccordementavecderivation.
¢hoisissez le raccordement appropri_ aux conditions requises de votre installation.
IkATTENTION :D branchez,'alimentation
_lectrique avant installation.
r_ Placez g_n_rateur chauffage sur
G_n@roteur de chQuffage
centrQI
Emplucement des trous et
des boulons
Zoneline
F2-1 Fixez g_n_rateur chauffage sur
le de central
le Zoneline vertical en faisant colncider les quatre trous des collerettes lat_rales sur les quatre
boulons sup_rieurs du Zoneline.
Emplucement des trous et des boulons
le de central
le Zoneline _ I'aide de 6 vis.
I
Option de raccordement normal
Raccordez le coude _ 90° au tugau de sortie
sup_rieur. Raccordez la vanne defermeture
I'autre extr_mit_ du coude _90°.
W]nne de
fermeture
Coude
90°
sup_rieur
Option de raccordement avec d_rivation
Raccordez le long tugau _ deux coudes au tugau
d'entr_e inf_rieur, tournez-le et raccordez-le au raccord en T du tugau de sortie. Raccordez la vanne
de fermeture _ I'autre extr_mit_ du raccord en T.
Wnne de
fermeture
RQccorden T
Tug(]u d'entr_e
0 deux coudes
inf_rieur
3
Loading...