GE RAP02 Installation Instructions

Installation Instructions for your new
RAP02 Dual Hose Conversion Kit
Before you begin - Read these instructions completely and carefully. IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer – Be sure to leave these instructions with the Consumer. Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.
Tools Needed
• Phillips head screwdriver • Small hand saw - if trimming of the window expansion panels is required
Parts Included:
1. Dual Hose Conversion Baffles (2)
2. Intake Hose Adapter to AC
3. Intake Hose Adapter to Window Kit
4. Intake Hose
5. Exhaust Hose Insulation
6. Dual Hose Window Panel
1.
2.3.
6.
4.
5.
1
IMPORTANT SAFETY INSTRUCTIONS
WARNING
shock, injury to persons, or damage when using the air conditioner, follow basic precautions, including the following:
Read all of the instructions before using this appliance.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Do not operate the air conditioner if it has a damaged
cord or plug, if it is not working properly, or if it has been damaged or dropped.
The air conditioner should be serviced only by qualified
service personnel. Call an authorized service company for examination, repair, or adjustment.
Disconnect power before servicing.
• Do not use means to accelerate the defrosting process
or to clean, other than those recommended by the manufacturer.
• The appliance shall be stored in a room without
continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
• Do not pierce or burn refrigerant tubing. Be aware that
refrigerants may not contain an odor.
• Keep ventilation openings clear of obstruction.
• When handling, installing, and operating the appliance,
care should be taken to avoid damage to the refrigerant tubing.
To reduce the risk of fire, electrical
WARNING
Risk of Fire or Explosion. This unit contains flammable refrigerant. Additional safety precautions must be followed.
Disconnect power before cleaning. NOTE: Turning off power by pressing the Power button
does NOT disconnect the appliance from the power supply.
Do not install or use the air conditioner in any area where the atmosphere contains combustible gases or where the atmosphere is contaminated. Avoid any chemicals coming in contact with your air conditioner.
Do not store anything directly on top of the air conditioner.
Use two or more people to move and install air conditioner.
Never operate the air conditioner without the filters in
place.
Do not use the air conditioner near a bathtub, shower or wash basin or other wet area.
• Do not drill holes in the unit.
• Maintenance, cleaning, and service should only be
performed by technicians properly trained and qualified in the use of flammable refrigerants.
• GE Appliances does not support any servicing of the air
conditioner.
• Dispose of air conditioner in accordance with Federal
and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.
2
Installation Instructions
Attach the Dual Hose Conversion Baffle to the Back of the Air Conditioner
STEP 1: Unplug or disconnect power
W ARNING
Electrical Shock Hazard
• Disconnect power before servicing
• Replace all parts and panels before operating
• Failure to do so can result in death or electric shock
STEP 1: Determine Location Requirements
• Place the air conditioner on a flat, level surface in a location that is at least 20” (51 cm) from any wall.
NOTE: A minim um clearance of 20” (51 cm) from the air conditioner to the wall must be maintained to ensure proper airflow.
• Maintain a minimum 20” (51 cm) clearance around
the air conditioner to not block airflow.
• Keep the air conditioner free of any obstructions
such as drapes, curtains, blinds, etc.
• The exhaust hose should be free of any
obstructions.
• Do not place the air conditioner on an unstable
or raised surface because it could fall and cause damage or injury.
Do not place the air conditioner in direct sunlight or near a heat source such as baseboard heaters, stoves, etc.
• The window panel can be installed in a window with
a minimum 20” (51 cm) to a maximum 48” (122 cm) opening.
STEP 3:
A Philips head screwdriver will be needed to remove the filter panel. Filter panel has qty (2) screws holding it in place.
STEP 4: Install dual hose conversion baffle depending on model
• Use the Small Dual Hose Conversion Baffle for these models:
APCD07JAL W , APWD07JASG, APCD08JAL W , APCD08JASW, APSD08JASG, APWD08JA WW
• Use the Large Dual Hose Conversion Baffle for these models:
APCD10JAL W , APCD10JASG, APWD10JASG, APWD10JAWG, APXD10JA WB
STEP 5:
If you previously installed your GE Portable Air Conditioner, you will need to remove the Window Kit from the window, exhaust hose adapter to AC and remove the Exhaust Hose Adapter to Window Kit. Remove the hose from the back of the AC and slide the fabric insulation over the hose. You can then re-attach the hose to the back of the AC.
STEP 6:
Once the exhaust hose is reattached to the back of the ac unit, If you have not installed your Portable AC yet, please follow the instructions to assemble the 2 adapters onto the exhaust hose to make up the exhaust hose assembly (step 2 of the installation instructions). Slide the fabric insulation over the hose, then assemble the hose assembly onto the back of the Air Conditioner.
3