GE RAK148F2, RAK164F2 Owner's Manual And Installation Instructions

SAFETY INFORMATION .............................. 2
OVERVIEW............................................................... 3
INSTALLATION ............................................. 4–7
CONFIGURATION MODE ........................ 8, 9
OPERATING FUNCTIONS ....................... 10
TESTING THERMOSTAT ...................11–12
TROUBLESHOOTING ................................... 13
THERMOSTAT
Digital Non-Programmable
OWNER’S MANUAL &
INSTALLATION INSTRUCTIONS
RAK148F2 RAK164F2
LIA319 9-7757 05-16 GEA
2
Specifications.
WARNING
FIRE AND SHOCK HAZARD
• Always turn off power at the main power supply before installing, cleaning or removing the thermostat. Failure to do so could result in electrical shock hazard.
• Do not use on voltages over 30 VAC. Higher
voltages will damage the thermostat and could cause shock or fire hazard.
NOTICE
• All wiring must conform to local and national electrical and building codes.
• Use this thermostat only as described in this manual.
Electrical rating: • 24 VAC (18–30 VAC)
1 amp maximum per terminal
4 amp maximum total load
Operating temperature range: 40°F–99°F (4°C–37°C) Temperature set range: 60°F–85°F (15°C–29°C) Accuracy: ± 1°F (± 0.5°C) System configurations:
RAK148F2: 2-stage heat (heat pump/resistance heat), 1-stage cool, 2-speed fan
RAK164F2: 1-stage heat (resistance heat), 1-stage cool, 2-speed fan
Terminations: R, C, W, Y, GH, GL, B (RAK148F2);
R, C, W, Y, GH, GL (RAK164F2)
Wiring:
Maximum wiring length is 66ft (20 meters) for
AWG18 Maximum wiring length is 60ft (18 meters) for AWG20
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
PARTS DIAGRAM
INTRODUCTION OVERVIEW
3
THERMOSTAT CONTROL
Auto
Cool Off
Heat
On
Low High
Display Up/Down Buttons
Function Switch
Fan Auto/On Switch
B GH GL Y W C
R
COOL OFF
HEAT
RESETRIGHTLEFT
AUTO ON
HIGH
LOW
Display
Up/Down Buttons
Wiring
Channel
Mounting
Hole
Function
Switch
Fan Auto/On
Switch
Mounting
Hole
Configuration
Buttons
Fan Speed Switch
Fan Speed
High/Low
4
INSTALLATION INSTRUCTIONS
WARNING
ELECTRICAL SHOCK HAZARD—Turn off power by unplugging the unit or by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. Failure to do so could result in risk of electric shock.
PACKAGE CONTENTS/ TOOLS REQUIRED
Package includes: Thermostat on base, thermostat
cover, wiring labels, screws and wall anchors.
Tools needed: 'ULOOZLWKƎELWKDPPHUVFUHZGULYHU
and putty.
5
TO REMOVE EXISTING THERMOSTAT
1. Turn off power to heating and cooling system by
removing the fuse or swi tching off the appropriate circuit breaker.
2. Remove cover of old thermostat. This should expose the wires.
3. Label the existing wires with the enclosed wire labels before removing wires.
4. After labeling wires, remove wires from wire terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how
to install this thermostat.
INSTALLATION INSTRUCTIONS
Loading...