CAUTION
Risk of Injury
Ware safety glasses and proper aid during installation and
maintenance
Notice:
TOOLS/ACCESSRIES YOU WILL NEED
Wire Stripper: Used for removal the insulation of wire lead.
Screwdriver – (3mm): used for connecting the power cord.
Screwdriver – (4mm): used for connecting safety chain.
Allen Key wrenches – (5mm) A/F: used for fixture and mounting
pole connection and adjustment.
P
PRE-INSTALLATION
1. Open the two latches of fixture, open the upper cover,
raise support (ensure it self-lock with hand help) and take
out the Accessory A of safety chain.
2. Loosen the screw of Accessory A to pull out the Safety
Chain.
(Figure 2)
I
INSTALL LUMINAIRE
1. Raise the fixture with the components of Accessory A
to planned installation pole.
2. Pull the Safety Chain through Pre-made Hole and the
two holes of Accessory A. Tighten the screw of
Accessory A. (Refer to the Figure 2)
3. Adjust the clamp plate to load the fixture to Pole (Keep
the upper cover of fixture open for observation to
ensure fixture fully loaded), tighten the three set
screws by turns.
4. Connect power supply leads: pull through leads from
the hole of cover, loosen screws of wiring clamp and
tighten them after pressing the leads, loosen the
screws on terminal block, connect leads properly in
accordance with Figure 3, tighten screws on terminal
block and wiring clamp. Connection is finished.
5. Install lamp:
Step 1 Disconnect the connector of lampholder wires.
Step 2 Open two latches of lampholder ’s cap and pull
out.
Step 3 Install the eligible recommended GE lamp
shown in PRODUCT BASIC INFO.
Step 4 Restore the lampholder cap.
1) Two men are required while installing.
2) Pre-made a hole of Ø4-6mm near the end of Pole for
Safety Chain.
3) Ensure Min. 25mm from the Accessory A while
locking Safety Chain. (Refer to the Figue 2)
4) Any situation, the torque of the three set screws
can’t too big to avoid mechanical damage.
5) Min. 3x1.0 mm
2
Power supply lead need be set in the
Pole.
(Figure 3)
V. MAINTENANCE/ LAMP REPLACEMENT
OPTICAL MAINTENANCE
In order to maintain high efficiency of reflectors and refractors,
a regular cleaning cycle should be established with frequency
dependent on local conditions. Use a mild soap or detergent
which is essentially neutral (pH approximately 6 to 8),
nonabrasive, and which contains no chlorinated or aromatic
hydrocarbons. Wash thoroughly, using a soft cloth, or brush if
necessary, Rinse in clean, cold water and wipe dry.
INSPECT AND REPLACE ANY DAMAGED REFRACTORS OR GASKET
IF APPLICABLE.
FAILURE PARTS NEED TO BE REPLACED IF YOU INSPECT THE
LAMP EXTINCT, FLICKING OR CYCLING. ORDER THE
REPLACEMENT PART INDIVIDUALLY. CONTACT THE
MANUFACTURES FOR THE MAINTENANCE SERVICE.
LAMP REPLACEMENT
Light output is also dependent on buring time of lamp. In
applications where light levels are critical, it may be desirable to
replace lamps before the end of life. Lamp manufacturer can
provide life curve date sheet of light output .
Step 1 Shut off power first.
Step 2 Open the two latches of fixture.
Step 3 Open the upper cover and raise support.
Step 4 Disconnect the connector of lampholder wires.
Step 5 Open two latches of lampholder’s cap and pull out .
Step 6 Remove the lamp that do not work properly.
Step 7 Reinstall the eligible recommended GE lamp shown in
PRODUCT BASIC INFO.
Step 8 Restore.
CAUTION: PLEASE NOTE THE LAMP TYPE, WATTAGE SHALL BE
SAME AS THE INDICATION OF PRODUCT LABEL.
If lamp is handled, fingerprint, grease or oils should be removed
from lamp with isopropyl alcohol. This will remove material
which will cause whitish spotting, and premature lamp failure.
Dry lamp carefully with cotton or clean cloth.
Accessory B: Fixed on lower
cover of fixture.
Pole
Safety Chain
Min. 25mm
Accessory A
Pre-made Hole
(Ø4-6mm)
Min. 3x1.0 mm2
Wire stripping 8~10mm
Neutral Wire-N