These Instructions do not purport to cover all details or variations in luminaire nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problem arise which are not covered sufficiently for the purchaser’s purpose, the matter should be referred to General Electric Company.
I. GENERAL
This luminaire is designed for outdoor lighting application, and should not be used in areas of limited ventilations, or in high ambient temperature enclosures. Best results will be obtained if installed and maintained according to the following recommendations. Please refer section III for the application limitation details.
The Manufacturer has made every effort during the design and construction stages to make its products completely free of risks when correctly used. Note however that accident prevention and safety regulations stipulate that the users of the product is obliged to ensure that all persons involved in servicing, installing, handling, using or selling the products are familiar with the information supplied by the Manufacturer and fully aware of any precautions that must be adopted. Depending on the circumstances, the instructions in this document must be communicated, together with any other information that may be necessary, to any Company or person involved in the installation of GE lighting products.
II. UNPACKING
The luminaire has been properly packed to avoid damage during transit. Inspect the luminaries to confirm there is no damage. Do not install a damaged luminaire or damaged luminaire components.
The carton consists of:
Fixture
Instruction Manual
(Figure 1)
Class I IP44 (Optical Housing IP66) 220V/50Hz
WARNING
CAUTION FOR ELECTRIC SHOCK/RISK OF BURN/PROPER INSTALLATION
Non-professionals are not allowed to operate. Shut off
the power before maintenance.
Risk of burn, allow lamps/fixture to cool down before
handling.
III. APPLICATION NOTICE
PLEASE APPLY THE PRODUCT ACCORDING TO FOLLOWING STATEMENT
QUNA is a roadway luminaire used for Major/Collector roadway, Highway, Commercial plaza, Industrial park, Residential area and Parking lots, etc. It can’t be installed in places with obvious vibration, like bridge/overpass, etc. It can be installed between 6m and 9m. Expected outer diameter of pole is 48-52mm.
IV. INSTALLATION
WARNING
1. Ensure this manual is provided to the installers and users.
2. Cut off the power before installation and maintenance.
3. Luminaire may fall down if not installed properly. Please follow the
instruction.
4. Lu minai re may fall down if the safety chain is not installed properly.
Please follow the instruction.
5. Never touch the lamps while they are working.
6. Replace the screen immediately if damaged or broken.
7. This fixture is only used for outdoor.
8. Not suitable for bridge and/or overpass application.
9. If installed in the places of high-salt environment (like coastal areas),
please contact the professionals of General Electric Company for more information.
Document No.:ZQKG/JS16-Qun10-2010 GE No.: GE2015-0738 ECN: CR2016-5622 Revision:C
CAUTION
Risk of Injury
Ware safety glasses and proper aid during installation and
maintenance
Notice:
TOOLS/ACCESSRIES YOU WILL NEED
Wire Stripper: Used for removal the insulation of wire lead. Screwdriver – (3mm): used for connecting the power cord. Screwdriver – (4mm): used for connecting safety chain. Allen Key wrenches – (5mm) A/F: used for fixture and mounting
pole connection and adjustment.
P
PRE-INSTALLATION
1. Open the two latches of fixture, open the upper cover,
raise support (ensure it self-lock with hand help) and take out the Accessory A of safety chain.
2. Loosen the screw of Accessory A to pull out the Safety
Chain.
(Figure 2)
I
INSTALL LUMINAIRE
1. Raise the fixture with the components of Accessory A
to planned installation pole.
2. Pull the Safety Chain through Pre-made Hole and the
two holes of Accessory A. Tighten the screw of Accessory A. (Refer to the Figure 2)
3. Adjust the clamp plate to load the fixture to Pole (Keep
the upper cover of fixture open for observation to ensure fixture fully loaded), tighten the three set screws by turns.
4. Connect power supply leads: pull through leads from
the hole of cover, loosen screws of wiring clamp and tighten them after pressing the leads, loosen the screws on terminal block, connect leads properly in accordance with Figure 3, tighten screws on terminal block and wiring clamp. Connection is finished.
5. Install lamp:
Step 1 Disconnect the connector of lampholder wires. Step 2 Open two latches of lampholder ’s cap and pull
out.
Step 3 Install the eligible recommended GE lamp
shown in PRODUCT BASIC INFO.
Step 4 Restore the lampholder cap.
1) Two men are required while installing.
2) Pre-made a hole of Ø4-6mm near the end of Pole for
Safety Chain.
3) Ensure Min. 25mm from the Accessory A while
locking Safety Chain. (Refer to the Figue 2)
4) Any situation, the torque of the three set screws
can’t too big to avoid mechanical damage.
5) Min. 3x1.0 mm
2
Power supply lead need be set in the
Pole.
(Figure 3)
V. MAINTENANCE/ LAMP REPLACEMENT
OPTICAL MAINTENANCE
In order to maintain high efficiency of reflectors and refractors, a regular cleaning cycle should be established with frequency dependent on local conditions. Use a mild soap or detergent which is essentially neutral (pH approximately 6 to 8), nonabrasive, and which contains no chlorinated or aromatic hydrocarbons. Wash thoroughly, using a soft cloth, or brush if necessary, Rinse in clean, cold water and wipe dry.
INSPECT AND REPLACE ANY DAMAGED REFRACTORS OR GASKET IF APPLICABLE.
FAILURE PARTS NEED TO BE REPLACED IF YOU INSPECT THE LAMP EXTINCT, FLICKING OR CYCLING. ORDER THE REPLACEMENT PART INDIVIDUALLY. CONTACT THE MANUFACTURES FOR THE MAINTENANCE SERVICE.
LAMP REPLACEMENT
Light output is also dependent on buring time of lamp. In applications where light levels are critical, it may be desirable to replace lamps before the end of life. Lamp manufacturer can provide life curve date sheet of light output .
Step 1 Shut off power first. Step 2 Open the two latches of fixture. Step 3 Open the upper cover and raise support. Step 4 Disconnect the connector of lampholder wires. Step 5 Open two latches of lampholder’s cap and pull out . Step 6 Remove the lamp that do not work properly. Step 7 Reinstall the eligible recommended GE lamp shown in
PRODUCT BASIC INFO.
Step 8 Restore.
CAUTION: PLEASE NOTE THE LAMP TYPE, WATTAGE SHALL BE SAME AS THE INDICATION OF PRODUCT LABEL.
If lamp is handled, fingerprint, grease or oils should be removed from lamp with isopropyl alcohol. This will remove material which will cause whitish spotting, and premature lamp failure. Dry lamp carefully with cotton or clean cloth.
Accessory B: Fixed on lower
cover of fixture.
Pole
Safety Chain
Min. 25mm
Accessory A
Pre-made Hole
(Ø4-6mm)
Min. 3x1.0 mm2
Wire stripping 8~10mm
Neutral Wire-N
Earth Wire
Line Wire-L
Fuze Tube Slot
Document No.:ZQKG/JS16-Qun10-2010 GE No.: GE2015-0738 ECN: CR2016-5622 Revision:C