GE QuickPanel+ IC755CxS06RDx, QuickPanel+ IC755CxW07CDx, QuickPanel+ IC755CxS10CDx, QuickPanel+ IC755CxS12CDx, QuickPanel+ IC755CxS15CDx User Manual

GFK-2847W
QuickPanel Operator
Interface
User
Manual
Dec 2017
IC755CxS06RDx (6” Display) IC755CxW07CDx (7” Display) IC755CxS10CDx (10" Display) IC755CxS12CDx (12” Display) IC755CxS15CDx (15” Display)
For public
disclosure
For public disclosure
These instructions do not purport to cover all details or variations in equipment, nor to provide for every
possible
contingency
to be met during installation, operation, and maintenance. The information is supplied for informational purposes only, and GE makes no warranty as to the accuracy of the information included herein. Changes, modifications, and/or improvements to equipment and specifications are made periodically and these changes may or may not be reflected herein. It is understood that GE may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time. This document is intended for trained personnel familiar with the GE products referenced herein.
GE may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not provide any license whatsoever to any of these patents.
Public – This document is approved for public disclosure.
GE provides the following document and the information included therein as is and without warranty of any kind, expressed or implied, including but not limited to any implied statutory warranty of merchantability or fitness for particular purpose.
For further assistance or technical information, contact the nearest GE Sales or Service Office, or an authorized GE Sales Representative.
Revised: Dec 2017 Issued: Nov 2013
© 2013 - 2016 General Electric Company.
* Indicates a trademark of General Electric Company and/or its subsidiaries. All other trademarks are the property of their respective owners.
We would appreciate your feedback about our documentation. Please send comments or suggestions to controls.doc@ge.com
GFK-2847W 3
For public disclosure
Document Updates
Location
Description
Appendix A Product Certifications and Installation Guidelines, Agency Approval
Updated ATEX Directive to 14/34/EU
Removed ATEX protection string - refer to the QP+ Operator Interface Installation and Maintenance Requirements (IMR) (GFK-2981)
Conditions of Safe Use for Installation in Hazardous Locations
Added the procedure for USB retaining clamps used in hazardous location installations for 7” Display units
Acronyms and Abbreviations
ARM Advanced RISC Machine BBSRAM Battery-backed SRAM
DRAM Dynamic Random Access Memory
FG Frame Ground FTP File Transfer Protocol GND Ground GUI Graphical user interface HTTP
HyperText Transfer Protocol
LCD Liquid Crystal Display
LED Light-emitting Diode
MIB Management Information Base (or Database)
OS Operating System
PME Proficy Machine Edition
RoHS Restrictions on Hazardous Substances SELV Safety Extra Low Voltage
SNMP Simple Network Management Protocol
USB Universal Serial Bus VESA Video Electronics Standards Association
4 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
Safety Symbol Legend
Warning
Indicates a procedure or condition that, if not strictly observed, could result in personal injury or death.
Caution
Indicates a procedure or condition that, if not strictly observed, could result in damage to or destruction of equipment.
Attention
Indicates a procedure or condition that should be strictly followed to improve these applications.
GFK-2847W 5
For public disclosure
Contact Information
If you purchased this product through an Authorized Channel Partner, then contact the seller directly.
General Contact
Information
Online technical support and GlobalCare
http://support.ge-ip.com
Additional information
http://www.ge-ip.com/
Solution Provider
solutionprovider.ip@ge.com
Technical Support
Contact us by telephone, email, or at http://support.ge-ip.com.
Americas
Online Technical Support
http://support.ge-ip.com
Phone
1-800-433-2682
International Americas Direct Dial
1-780-420-2010 (if toll free 800 option is unavailable)
Technical Support Email
support.ip@ge.com
Customer Care Email
customercare.ip@ge.com
Primary language of support
English
Europe (not Germany), Middle East, and Africa (EMEA)
Online Technical Support
http://support.ge-ip.com
Phone
+ 800-1-433-2682
EMEA Direct Dial
+ 420-23-901-5850 (if toll free 800 option is unavailable or dialing from a mobile telephone)
Technical Support Email
support.emea.ip@ge.com
Customer Care Email
customercare.emea.ip@ge.com
Primary languages of support
English, French, Italian, Czech, Spanish
Germany
Online Technical Support
http://support.ge-ip.com
Address
GE Intelligent Platforms GmbH
Memminger Str. 14
86159 Augsburg Germany
Phone
+ 49-821–5034–0 + 800–322–3616
Fax
+ 49–821–5034–119
Technical Support Email
sales.augsburg.ip@ge.com
Asia Pacific
(APO)
Online Technical Support
http://support.ge-ip.com
Phone + 86-400-820-8208
+ 86-21-3217-4826 (India, Indonesia, and Pakistan)
Technical Support Email
support.cn.ip@ge.com (China)
support.jp.ip@ge.com (Japan)
support.in.ip@ge.com (remaining Asia customers)
Customer Care Email
customercare.apo.ip@ge.com
customercare.cn.ip@ge.com
(China)
6 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
Notes
GFK-2847W 7
For public disclosure
Contents
1
Overview ..................................................................................................................................... 9
1.1 Specifications
................................................................................................. ............ ............................... 10
1.1.1 Physical Specifications and Mounting
Options............................................................................. 10
1.1.2 Environmental
Specifications ....................................................................................... ................. 15
2
Hardware.................................................................................................................................. 17
2.1 Physical Characteristics
........................................................................................................................... 17
2.2 LED
Indicators............. ............................................................................................................................... 23
2.2.1 Operation Status
LEDs.................................................................. ..................................... ............. 23
2.2.2 Ethernet Port Operation LEDs
...................................................................... ................................. 23
3
Software .................................................................................................................................... 25
3.1 Operating System
................................. .................................................................................................... 25
3.2 Backup
Utility............................................................................................................................................. 25
3.3 Storage Manager
...................................................................................................................................... 25
3.4 Copy Project to SD
Card .............................. .............................................................................................. 26
3.5 Proficy Machine Edition Project
Update................................................................................................... 26
3.6 FTP
Server ..................................................................................................................................... ............. 27
3.6.1 Remote User Authentication
......................................................................................................... 27
3.6.2 FTP with Removable Flash Devices
.................................. ............................................................ 27
3.7 HTTP Server
................................... ........................................................................................................... 28
3.8 SNTP
Server............................................................................................................................................... 28
3.9 QuickPanel+ OS Utilities Settings Tool
..................................................................................................... 29
3.9.1 Firmware Upgrade
............................................................... ...................................... .................... 30
3.9.2 Firmware Upgrade for Specific Build
Version............................................................. ................... 32
3.9.3 Bypass Startup
Programs ............................................................................................................... 33
3.9.4 Reset Enhanced Security
...................................................................................................... .......... 35
3.9.5 Enable or Disable
SNMP
Agent
....................................................................................................... 36
3.10 Display Screen Sensitivity
Tool .................................................................................................. ..... ......... 38
3.11 Launch
Application .................................................................................................................................. 39
3.12 VNC
Server ........................................................................ ................................................................... .... 40
3.13 Battery Life
Prediction............................................................................................................ ................. 41
3.14 Simple Network Management Protocol
(SNMP) .................................................................................... 45
3.14.1 Configure Trap
Destinations.............................. .......................................................................... 49
3.14.2 Enable or Disable
SNMP
Agent
.................................................................................................... 50
3.14.3 Export MIB to SD
Card.................................................................................................................. 50
3.14.4 Load MIB into SNMP
Manager ....................... .................................... ....... .................................. 51
3.14.5 Data Types Mapping between PME Project and SNMP
................................. ............................ 52
3.14.6 Establish SNMP
Communication ................................................................................................. 52
3.15 Screensaver…………..
.............................................................. .................................................................. 53
4 Pre-installation
Checks........................................................................................................ 55
4.1 Unpacking and Inspection
................................................................................................................... 55
4.2 Basic Setup
............................................................................................................................................ 57
4.3 Initial
Startup ................................... ...................................................................................................... 58
4.3.1 Connecting Input
Power ..................................................................................................... 58
4.3.2 Initial
Configuration ...................................... ...................................................................... 59
8 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
4.4 Runtime Setup
............................. ......................................................................................................... 59
4.5 Firmware
Updates........................................... ...................................................................................... 60
4.6
Shutdown .................................................................................................................... .......................... 60
5 Mounting and
Installation...................................................................................................... 61
5.1 Protective Sheet
Installation .................................................................................................................... 61
5.2 Mounting Location
................................................................................................................................... 62
5.3 Panel
Mounting ......................................................................................................................................... 63
5.4 Mounting and Installation Procedure
..................................................................................................... 66
5.5 VESA Arm
Mounting........................... ....................................................................................................... 68
5.6 Battery Installation and
Replacement .................................................................................................... 69
5.6.1
IC755CxS06RDx ................................................................. .............................................................. 70
5.6.2
IC755CxW07CDx.............. ............................................................................. ..... ............................. 72
5.6.3
IC755CxSxxCDx ............................................................................................................................... 74
5.7
Connectors ................................................................................................... ....... ................................ ..... 76
5.7.1 Power Connector Pin-out for IC755CxS06RDx, IC755CxW07CDx, and
IC755CxSxxCDx ........... 76
5.7.2 Ethernet for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx
................... ................... 76
5.7.3 Serial Port Details
........................................................................................................................... 78
5.7.4 Universal Serial Bus (USB)
Ports ..................................................................................................... 84
5.7.5 Audio (LINE OUT) Details for IC755CxS06RDx, IC755CxW07CDx, and
IC755CxSxxCDx ............. 85
5.7.6 Audio (MIC IN) Details (Only Applicable to IC755CxS06RDx and
IC755CxW07CDx).................... 85
5.7.7 SD Card Slot and Storage
............................................................. .................................................. 86
6
Operation ...................................................................................................................................... 89
6.1 Touchscreen Display
................................................................................................................................ 89
6.1.1 Display Brightness
Adjustment ............................................................................................... 89
6.1.2 Display Backlight
Configuration ........................ ............................... ....................................... 90
6.1.3 Touchscreen
Re-calibration ..................................................................................................... 91
6.2 Keyboard
Configuration..................................................................................................................... ....... 92
6.2.1 External Keyboard
(Optional)........................................... ......................................................... 92
6.2.2 Soft Input
Panel ......................... ................................................................................................ 92
6.3 Mouse
................................. ....................................................................................................................... 92
6.4
Printing..................................................................................... ...................................... ............................ 93
6.5 Memory
............................................................................ .................................... ................................ ..... 94
6.5.1 DRAM Memory
..................................................................................................................... 94
6.5.2 Memory Allocation
Modification ............................................................................................. . 95
7 Secomea Security
(Optional).................................................................................................... 97
7.1 Secomea Configuration
Tool ..................................................... .................................................. ............. 97
7.2 Secomea
Products .................................................................................................................................... 98
8 Save and Restore Settings…………………………………………………………………………………………100
Appendix A Product Certifications and Installation
Guidelines.........................................
107
Appendix B Orderable Part
Numbers
Appendix C IC755CxS10CDx, IC755CxS12CDA, and IC755CxS15CDx Serial Port Details
Overview
For public disclosure
GFK-2847W 9
1 Overview
Note This manual specifically describes the QuickPanel+ IC755CxS06RDx, IC755CxWxxCDx and IC755CxSxxCDx
display units.
The QuickPanel+ Operator Interface is an all-in-one micro-computer designed for maximum flexibility. The design is based on an Advanced RISC Machine (ARM) core micro-processor to combine a high-resolution touchscreen operator interface with a variety of communications options. Users can connect to most industrial equipment using the QuickPanel+ communications ports.
The QuickPanel+ is equipped with several memory types to satisfy the most demanding applications. A section of Dynamic Random Access Memory (DRAM) is split between the operating system, an object store, and application memory. Additionally, a section of Non-volatile Random Access Flash Memory (NOVRAM), functioning as a virtual hard drive, is divided between the operating system and persistent storage for application programs. Retentive memory is a battery-backed Static Random Access Memory (SRAM) to store and protect data during a power failure.
QuickPanel+ Operator Interface
Display
10 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
1.1 Specifications
1.1.1 Physical Specifications and Mounting Options
1.1.1.1 IC755CxS06RDx Specifications
Item
Specification
Processor
Freescale i.MX535 (1 GHz ARM Cortex A8)
Memory RAM
DDR3 SDRAM 512 MB
ROM
NAND FLASH 256 MB
SRAM
512 KB (with battery backup)
Operating System
Microsoft Windows Embedded Compact 7
Display
Type
5.7” TFT LCD
Resolution
320(W) x 240(H) pixels QVGA
Color
65,536
Brightness
375 cd/m
2
Backlight
LED
Touchscreen Touch Panel Type
Analog Resistive
Multi-touch
Single-touch
Communications
Ethernet Port
1x10Base-T / 100Base-TX
Serial Port
1x RS-232C (COM1) (5-pin connector)
USB, Host
2x USB 2.0 (Type-A) maximum power (5 V at 0.5 A)
USB, Device
1x USB 2.0 (mini Type-B)
Storage
1x SD/SDHC card slot
Audio
1x Mic In (Mono) (3.5 mm jack), 1x Line Out (Stereo) (3.5 mm jack)
Noise Immunity Noise Voltage
1500 V p-p
Pulse Duration
1µs
Rise Time
1ns
Input power Rated Voltage
24 V dc ±20% (3-pin connector)
Power Consumption
15 W maximum
Frame Ground (FG)
Frame Ground (GND) is connected internally to Signal GND
Dimensions (L×W×D)
192 × 137 × 36 mm (7.56 × 5.39 × 1.42 in)
Weight
0.7 Kg (1.54 lb)
Mounting Options Panel Cutout Dimensions
183.50 × 128.50 mm (7.22 × 5.06 in)
VESA Mount
75 x 75 mm (2.95 x 2.95 in)
Overview
For public disclosure
GFK-2847W 11
1.1.1.2 IC755CxW07CDx Specifications
Item
Specification
Processor
Freescale i.MX535 (1 GHz ARM Cortex A8)
Memory RAM
DDR2 SDRAM 512 MB
ROM
SLC NAND 256 MB
SRAM
512 KB (with battery backup)
Operating System
Microsoft Windows Embedded Compact 7
Display
Type
7" Widescreen TFT LCD
Resolution
800(W) x 480(H) pixels WVGA
Color
65,536
Brightness
310 cd/m
2
Backlight
LED
Touchscreen Touch Panel Type
Projected capacitive
Multi-touch
Two-point
Communications
Ethernet Port
1x 10/100Base-T (RJ-45)
Serial Port
1x RS-232 UART port (5-pin connector)
USB, Host
2x USB 2.0 (Type-A) maximum power (5 V at 0.5 A)
USB, Device
1x USB 2.0 (mini Type-B)
Storage
1x SD/SDHC card slot
Audio
1x Mic In (Mono) (3.5 mm jack) 1x Line Out (Stereo) (3.5 mm jack)
Noise Immunity Noise voltage
1500 V p-p
Pulse duration
1µs
Rise time
1ns
Input power Rated Voltage
24 V dc ±20% (3-pin connector)
Power Consumption
15 W maximum, 0.625 A
Frame Ground (FG)
Frame GND is connected internally to Signal GND
Dimensions (L×W×D)
192 × 137 × 36 mm (7.56 × 5.39 × 1.42 in)
Weight
0.80 kg (1.76 lbs)
Mounting Options Panel Cutout Dimensions
183.50 × 128.50 mm (7.22 × 5.06 in)
VESA Mount
75 x 75 mm (2.95 x 2.95 in)
12 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
1.1.1.3 IC755CxS10CDx Specifications
Item
Specification
Processor
Freescale i.MX535 (1 GHz ARM Cortex A8)
Memory RAM
DDR3 SDRAM 1 GB
ROM
SLC NAND 512 MB
SRAM
512 KB (with battery backup)
Operating System
Microsoft Windows Embedded Compact 7
Display
Type
10.5" Standard TFT LCD
Resolution
800(W) x 600(H) pixels SVGA
Color
65,536
Brightness
400 cd/m
2
Backlight
LED
Touchscreen Touch Panel Type
Projected capacitive
Multi-touch
Two-point
Communications
Ethernet Port
2x 10/100Base-T (RJ-45)
Serial Port
1x RS-232 UART port 1x RS-232/485 port (2x 5-pin connector)
USB, Host
2x USB 2.0 (Type-A) maximum power (5 V at 0.5 A)
USB, Device
1x USB 2.0 (mini Type-B)
Storage
1x SD/SDHC card slot
Audio
1x Line Out (Stereo) (3.5 mm jack)
Noise Immunity Noise voltage
1500 V p-p
Pulse duration
1µs
Rise time
1ns
Input power Rated Voltage
12/24 V dc ±20% (3-pin connector)
Power Consumption
18 W maximum 1.5 / 0.75 A
Frame Ground (FG)
Frame GND is connected internally to Signal GND
Dimensions (L×W×D)
278 × 222 × 65 mm (10.95 × 8.74 × 2.56 in)
Weight
2.40 kg (5.29 lbs)
Mounting Options Panel Cutout Dimensions
266 × 210 mm (10.47 × 8.27 in)
VESA Mount
100 x 100 mm (3.94 x 3.94 in)
Overview
For public disclosure
GFK-2847W 13
1.1.1.4 IC755CxS12CDx Specifications
Item
Specification
Processor
Freescale i.MX535 (1 GHz ARM Cortex A8)
Memory RAM
DDR3 SDRAM 1 GB
ROM
SLC NAND 512 MB
SRAM
512 KB (with battery backup)
Operating System
Microsoft Windows Embedded Compact 7
Display
Type
12.1" Standard TFT LCD
Resolution
800(W) x 600(H) pixels SVGA
Color
65,536
Brightness
450 cd/m
2
Backlight
LED
Touchscreen Touch Panel Type
Projected capacitive
Multi-touch
Two-point
Communications
Ethernet Port
2x 10/100Base-T (RJ-45) 1x 10/100Base-T (RJ-45) for IC755CxS12CDA
Serial Port
1x RS-232 UART port 1x RS-232/485 port (2x 5-pin connector) (1x 10-pin connector for IC755CxS12CDA)
USB, Host
2x USB 2.0 (Type-A) max power (5 V at 0.5 A)
USB, Device
1x USB 2.0 (mini Type-B)
Storage
1x SD/SDHC card slot
Audio
1x Line Out (Stereo) (3.5 mm jack)
Noise Immunity Noise voltage
1500 V p-p
Pulse duration
1µs
Rise time
1ns
Input power Rated Voltage
12/24 V dc ±20% (3-pin connector)
Power Consumption
30 W maximum, 2.5 / 1.25 A
Frame Ground (FG)
Frame GND is connected internally to Signal GND
Dimensions (L×W×D)
314 × 248 × 65 mm (12.36 × 9.76 × 2.56 in)
Weight
3 kg (6.61 lbs)
Mounting Options Panel Cutout Dimensions
302 × 228 mm (11.89 × 8.98 in)
VESA Mount
100 x 100 mm (3.94 x 3.94 in)
14 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
1.1.1.5 IC755CxS15CDx Specifications
Item
Specification
Processor
Freescale i.MX535 (1 GHz ARM Cortex A8)
Memory RAM
DDR3 SDRAM 1 GB
ROM
SLC NAND 512 MB
SRAM
512 KB (with battery backup)
Operating System
Microsoft Windows Embedded Compact 7
Display
Type
15" Standard TFT LCD
Resolution
1024(W) x 768(H) pixels XGA
Color
65,536
Brightness
310 cd/m
2
Backlight
LED
Touchscreen Touch Panel Type
Projected capacitive
Multi-touch
Two-point
Communications
Ethernet Port
2x 10/100Base-T (RJ-45)
Serial Port
1x RS-232 UART port 1x RS-232/485 port (2x 5-pin connector)
USB, Host
2x USB 2.0 (Type-A) maximum power (5 V at 0.5 A)
USB, Device
1x USB 2.0 (mini Type-B)
Storage
1x SD/SDHC card slot
Audio
1x Line Out (Stereo) (3.5 mm jack)
Noise Immunity Noise voltage
1500 V p-p
Pulse duration
1µs
Rise time
1ns
Input power Rated Voltage
12/24 V dc ±20% (3-pin connector)
Power Consumption
30 W maximum, 2.5 / 1.25 A
Frame Ground (FG)
Frame GND is connected internally to Signal GND
Dimensions (L×W×D)
399 × 323 × 70 mm (15.71 × 12.72 × 2.76 in)
Weight
4.46 kg (9.83 lbs)
Mounting Options Panel Cutout Dimensions
379 × 305 mm (14.92 × 12.01 in)
VESA Mount
100 x 100 mm (3.94 x 3.94 in)
Overview
For public disclosure
GFK-2847W 15
1.1.2 Environmental Specifications
Note Install the QuickPanel+ in a well-ventilated location that is not exposed to dust, corrosive gases or liquids, rain,
strong ultra-violet light or direct sunlight, and meets the following specifications.
Item
IC755CxS06RDx
IC755CxW07CDx
IC755CxS10CDx
IC755CxS12CDx
IC755CxS15CDx
Cooling
Natural
convection
Ambient Operating Temperature
0 to 55°C (32 to 131
°F)
Ambient Storage Temperature
-10 to 60°C (14 to 140
°F)
Ambient Humidity (Operating and Storage)
85% RH Non-condensing, wet-bulb temperature: 30°C (86 °F) or less
Environment
Pollution Degree 2, Indoor use
only
Vibration Resistance
5 to 9 Hz single-amplitude 3.5 mm; 9 to 150 Hz
constant-accelerated
velocity 9.8 m/s2; X, Y,
Z directions 10 time (100 minutes) (Compliance 3502, IEC61131-2 JIS B)
Altitude
800~1114 hPa, altitude up to 2000 m (6561.68 ft)
RoHS
Compliant with EU RoHS Directive 2011/65/EU
Enclosure Rating
UL
Type 4X rating; IP65 in panel mount only
Note For additional product standards and agency approvals, refer to Appendix A.
16 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
Notes
Hardware
For public disclosure
GFK-2847W 17
2 Hardware
This chapter describes the QuickPanel+ hardware features, including physical characteristics and LED indicators.
2.1 Physical Characteristics
In addition to the primary touchscreen interface, the QuickPanel+ Operator Interface supports a variety of communication ports. The following diagrams illustrate the physical layout of the QuickPanel+ Operator Interface, including locations of status LEDs, communications ports, and connectors.
18 GFK-2847W
For public disclosure
QuickPanelOperator Interface User
144.7 (5.70 in)
128.50 (5.06 in)
75 (2.95 in)
137 (5.39 in) x 2
192 (7.56 in) x 2
36 (1.42 in) x 2
115.2
(4.5 in)
SD Card
LCD Active Area
115.2 x 86.4 (4.5 x 3.4 in)
Serial Interface
Input Power
LAN
USB Host Ports
USB Device
LINE OUT
MIC IN
183.50 (7.22 in) 75 (2.95 in)
Battery Cover
Effective Screw Depth 6 mm (0.24 in)
License Label
Product Nameplate
IC755CxS06RDx Hardware
Features
Hardware
For public disclosure
GFK-2847W 19
Touchscreen
LCD
Status
Indicator LED
SD Card
MICRO USB
LINE OUT
MIC IN
I
nput
Power
LAN
USB Host
Ports
COM
Battery Cover
IC755CxW07CDx Hardware
Features
Note Refer to the section IC755CxW07CDx Specifications for drawing dimensions.
20 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
SD Card
Stat
us
Indicator LED
T
ouchscreen
LCD
LAN2
LAN1
U
SB
Hos
t
Port
s
MICRO COM2
USB
COM1 LIN
E
OUT
I
nput
P
ower
IC755CxS10CDx Hardware
Features
Note Refer to the section IC755CxS10CDx Specifications for drawing dimensions.
Hardware
For public disclosure
GFK-2847W 21
!
!
IC755CxS12CDx Hardware
Features
Note Refer to the section IC755CxS12CDx Specifications for drawing dimensions.
22 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
SD Card
T
ouchscre en
LCD
Stat
us
I
ndicator
LED
LAN2
LAN1
USB
MICRO COM2 COM1
LIN
E
I
nput
Host Port
s
USB
OUT
P
ower
IC755CxS15CDx Hardware
Features
Note Refer to the section IC755CxS15CDx Specifications for drawing dimensions.
Hardware
For public disclosure
GFK-2847W 23
2.2 LED Indicators
The QuickPanel+ Operator Interface provides LED indication for the following:
Operation status
Ethernet Port operation
2.2.1 Operation Status LEDs
The QuickPanel+ has one tri-color LED that provides visual operation status indication for IC755CxS06RDx, IC755CxW07CDx, the and IC755CxSxxCDx units.
LED State
QuickPanel+ State
Amber, solid
Operating system starting
Green, solid
Normal operating state
Green, blinking
Backlight off
Red, blinking
Backlight failure
Off
Power not applied to unit
2.2.2 Ethernet Port Operation LEDs
The Ethernet port has two LED indicators: Speed and Link Activity.
Speed Link Activity
LED
LED State
Operating State
Speed
Yellow, on
10/100
Link Activity
Green, on
Link status
24 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
Notes
Software
For public disclosure
GFK-2847W 25
3 Software
This chapter provides QuickPanel+ software information and procedures to perform the most common tasks.
3.1 Operating System
Note Refer to http://windows.microsoft.com.
The QuickPanel+ operating system (OS), Microsoft Windows Embedded Compact 7, is a full 32-bit OS with graphical user interface (GUI). It is stored in flash memory and copied to a block of DRAM for execution. The OS automatically starts following QuickPanel+ unit powerup or reset.
3.2 Backup Utility
Attention
Run the Backup Utility after configuration changes to the operating system or installing applications, and before shutdown.
The QuickPanel+ is not battery powered; therefore, a Backup Utility feature saves the changes made to the Windows Registry or Desktop to Flash Memory. The Backup Utility achieves the following:
Stores the Windows Embedded Compact 7 registry (including any control panel settings) in Flash memory
Stores changes (or additions) made to the \Windows sub-tree of the file system in the user block of flash memory
3.3 Storage Manager
Note Storage Manager is accessed from the Control Panel folder. Online help is available.
Use Microsoft Storage Manager to repair or format lost or corrupted data volumes existing in the SD Card, battery-backed SRAM (BBSRAM), or USB Flash Keys (thumb drives).
Note Data volumes existing in the main flash file system of the QuickPanel+ may not be repaired by Storage Manager.
26 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
3.4 Copy Project to SD Card
The custom utility Copy Project to SD Card transfers Proficy Machine Edition View and Control projects between compatible QuickPanel+ units using SD cards.
Caution
Before disconnecting power, verify that the copy or update operation is complete (no busy message or wait cursor).
To copy a Proficy Machine Edition project to an SD card
1. Verify that there is a blank SD card in the SD card port.
2. Double tap the Copy Project to SD Card icon on the desktop.
3. If the project is secured with an enhanced security password, then the password authentication window will be
displayed. The user shall be able to proceed only when the password is successfully authenticated.
4. From the Copy Project Query confirmation window, tap Yes.
Caution
Copying a project while Proficy Machine Edition runtimes are active may cause an incomplete copy to be created if the runtimes are also writing to files in the project folders. If the utility detects this situation, it will notify you to stop the runtimes before making the backup. You will not be able to create a backup while the runtimes are writing files.
3.5 Proficy Machine Edition Project Update
Update a Proficy Machine Edition (PME) application that is currently stored on the QuickPanel+ unit with a revision stored on a
flash device, such as an SD card.
To update a Machine Edition project
1. Insert the flash device containing an upgraded version of the Proficy Machine Edition project into the appropriate port.
2. Restart the unit.
Note Depending on set options, the update may or may not be enabled, or may update automatically. If there is more than one flash device with a valid project copy present, a Select Media confirmation window displays, prompting you to choose with which flash device to update Select the device from the list and click OK to continue. When a valid project is found on the flash device, you will be prompted to install the project or skip it. Tap OK to install or Cancel to skip the installation, and continue to restart. If an invalid project is found, an error message displays. This window must be closed before the unit will restart.
3. Remove the flash device from the port.
Software
For public disclosure
GFK-2847W 27
3.6 FTP Server
The File Transfer Protocol (FTP) server included with the QuickPanel+ unit supports standard (RFC 959). It does not support Secure File Transfer Protocol (SFTP) or implicit FTPS, which uses different ports and is based on Secure Shell (SSH) rather than Secure Sockets Layer (SSL).
The FTP server is configured with the Quick Panel+ Setup Tool. By default, the server is not enabled. Once enabled, a background program will run, waiting for clients to connect. Up to ten connections are supported. Sessions that are idle for five minutes are terminated by the server.
The server supports non-secure operation. All information including username, password, and data is transmitted with no encryption and is susceptible to packet sniffing and various FTP attacks.
Note If the server status is changed, the QuickPanel+ must be restarted before changes take effect.
3.6.1 Remote User Authentication
Note The FTP root directory is available from the QuickPanel+ as \, and is the root of the flash device.
The server only supports anonymous login with password requested (but not validated). This may prevent some types of attacks and is required by some clients. Once connected, the remote user is logged into the FTP root directory.
3.6.2 FTP with Removable Flash Devices
All removable flash devices remote-FTP users as directories off the FTP root directory. Computer Flash card partitions display as directories such as \SDMemory and USB Flash Keys display as directories such as \Hard Disk. Full access privileges are granted for the client in these folders/devices.
Removable flash device directories are captured when a session is opened and are not changed while the session exists. If you start without an installed SD Card, close your session and log on again to view the SD Card directory. If the SD Card existed when you logged on, and is removed and inserted, it will still work, provided the SD Card’s device name did not change during
reinsertion.
28 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
3.7 HTTP Server
The HyperText Transfer Protocol (HTTP) server included with the QuickPanel+ supports standard (RFC 2616). The HTTP server is configured with the Quick Panel+ Setup Tool. By default, the server is not enabled. Once enabled, a background program will run, waiting for clients to connect. From the QuickPanel+ Operator Interface, the default web page is located in \Windows\www\wwwpub.
The server supports non-secure port 80 operation.
Note If the server status is changed, the QuickPanel+ must be restarted before changes take effect.
3.8 SNTP Server
The SNTP server included with the QuickPanel+ supports SNTP Version 4 for IPv4, IPv6 and OSI. The SNTP server is configured with the Quick Panel+ Setup Tool. By default, the server is not enabled. Once enabled, the server will refresh the time specified in the setup tool configuration. Pressing the Update Now button immediately obtains the time from the configured time server.
The SNTP server supports non-secure UDP port 123 operation.
Software
For public disclosure
GFK-2847W 29
3.9 QuickPanel+ OS Utilities Settings Tool
Note DIP switches are set in the OFF position (default) in the factory.
The QuickPanel+ Operator Interface is equipped with DIP switches to perform control functionality, as follows:
DIP Switch 1 (SW2 Switch) enables firmware upgrade. Firmware upgrade is allowed only after turning this switch in the ON position. It is highly recommended to turn the switch position to OFF after firmware upgrade is completed as a security measurement.
DIP Switch 2 (SW2 Switch) controls Force Startup. Turning this switch to the ON position forces the startup applications to run when the operating system is started.
Note The DIP Switch feature is designed as a security measurement. However, security requirements can also be met using the gesture-based feature.Prior to the listed firmware builds, these operations were only supported using the DIP Switch settings.
Some operators find it difficult to use the DIP Switch settings to perform these functions (such as removing the back plate of the device and adjusting the positions of DIP Switch for each operation). As an alternative to using the DIP Switch settings, the QuickPanel+ OS Utilities Settings tool contains finger gesture-based utilities to perform the same operations. This functionality is available with the firmware builds listed in the following table.
QuickPanel+ OS Utilities Settings Tool Support
QuickPanel+ Product
Firmware Build
IC755CxS06RDx (6" Display)
01 (initial
release)
IC755CxW07CDx (7” Display)
21
IC755CxS10CDx (10” Display)
12
IC755CxS12CDx (12” Display)
IC755CxS15CDx (15” Display)
The tool operation buttons for each utility only respond to a double-tap finger gesture. It will not accept any keyboard or mouse clicks, finger simulator-based inputs, or click inputs from any remote touch-based device. The user can access the tool from the Start menu by selecting Programs, System, and QuickPanel+ OS Utilities Settings on the device. The tool can be used to perform the following operations using the double-tap feature, without adjusting the DIP Switch positions:
Firmware Upgrade
Bypass Startup Programs
Reset Enhanced Security
Enable/Disable
SNMP
Agent
Attention
For security, only permit these operations when the operator is physically located near the QuickPanel+ and require that users perform a physical action on the device.
30 GFK-2847W
For public disclosure
QuickPanel Operator Interface User
3.9.1 Firmware Upgrade
Note This utility operates similar to the QuickPanel+ Update Tool, which comes with the OS image upgrade binaries.
The operator can continue to use the QuickPanel+ Update Tool to use the DIP Switch feature.
The Firmware Upgrade utility setting enables operators to upgrade the firmware. Firmware updates are not supported over
Ethernet or Serial interfaces. Insert the media (SD Card) containing the required files for firmware upgrade and perform the following procedure.
Note Make sure the copy of required binaries to the SD card is not within a folder.
Note The firmware package contains encrypted .nbo files. Use the PreUpdate.exe tool to decrypt the .nbo files before
using them for upgrade.
After a firmware upgrade, which refreshes the device fresh, the user must download the project again and install their own tools (including third party tools) on the device.
Note It is recommended that the user back up any important data prior to firmware upgrade so that they can replace the data after firmware upgrade if necessary.
If the current firmware build version on the QuickPanel+ is any of the following, refer to the section Firmware Upgrade for Specific Build Version:
Build 3 or below for IC755CxS06RDx
(6” Display)
Build 23 or below for IC755CxW07CDx
Attention
(7” Display)
Build 14 or below for
IC755CxS10CDx
(10" Display), IC755CxS12CDx
(12” Display), and IC755CxS15CDx
(15” Display)
Loading...
+ 88 hidden pages