GE PSI23MGNBB, PSI23MGN, PSI23MGNCC, PSI23MGNWW User Manual

PSI23MGN—GE Profile Arctica™22.7 Cu. Ft. CustomStyle™Side-by-Side Refrigerator with Dispenser
Specification Created 11/01
TM
Case Dimensions (in inches/cm.)
C
F
D
E
Side View
Front View
69-1/4
68-3/4
28-5/16
26-3/4
23-7/8
69-1/4
Manufacturer Certified to
ASSOCIATION OF HOME
APPLIANCE MANUFACTURERS
ANSI/AHAN HRF-1-1979
VOLUME and SHELF AREA
R
Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
I
H
G
J
Top View
35-3/4
45-9/16
37-5/16
For answers to your Monogram,®GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
PSI23MGNGE Profile Arctica™22.7 Cu. Ft. CustomStyle™Side-by-Side Refrigerator with Dispenser
Specification Created 11/01
TM
Manufacturer Certified to
ASSOCIATION OF HOME
APPLIANCE MANUFACTURERS
ANSI/AHAN HRF-1-1979
VOLUME and SHELF AREA
R
Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers standards.
Listed by Underwriters Laboratories
For answers to your Monogram,®GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
Standard, New Construction and Replacement Installation
Rough-In Dimensions
• All wall/floor molding should be removed prior to installation.
• Water recess on rear wall recommended to prevent water line damage. 48" minimum length 1/4" diameter water line tubing recommended.
• When possible, recess both copper water line and electrical outlet. (See local codes)
• Front and rear leveling legs are adjustable for the built-in look. (See owner’s manual)
• If optional collar trim kit is to
be used or anticipated, see collar trim installation on next page for different rough-in dimensions.
8' Ceiling
13" to 14" Cabinet
12" Soffit
70-1/4"*
36-1/8"
24-1/2"
*The rough-in dimension of 70-1/4" is minimum and is measured from the
finished floor to top of opening (or the underside of the overhead cabinets). For Models with Trim Kit: If frameless style cabinets are planned for above the refrigerator, you may need to consider adding a maximum of 1/4" (70-1/2") to height of opening to allow additional clearance between cabinet doors and top of refrigerator trim when cabinet doors are in open position.
25" Counter Top
Electrical Water
3/4" Airspace (1/2" Gap + 1/4"
Wall Plates) 24" Cabinet
Installation of Water and Electrical Outlets
Alternate water line location through floor
1/2"
Top View
Recommended water line location using recess in rear wall
Recommended single loop of 1/4" copper water line
Water hook-up on the refrigerator
Rear Wall View
18"
24"
Allow 48" minimum water line to enable refrigerator to be pulled forward
Loading...