GE PROFILE PGP989DN/TN, Profile PGP989DNBB, Profile PGP989TNWW Dimensions And Installation Information

Dimensions and Installation Information
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Listed by Underwriters Laboratories
Specification Revised 4/09
230284
*Note: A 5" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
Wall Installation: Wall installations require 25” countertop
depth. When cabinet is flush against the wall, the fan housing can be rotated to the horizontal position for direct venting through rear wall. Make a countertop cutout in the range cabinet according to unit dimensions and installation type. Duct hole is positioned in back of cabinet for through-the-wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/ islands a minimum 26”
countertop
depth is suggested. Blower should be in vertical position. Island or peninsula cabinets may require adjustment in cutout depth and/or location within the width dimensions. Duct hole is positioned in bottom of cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and rear wall ducting, 6” PVC duct or locally
approved piping should be used if installing under a poured concrete slab.
Installation Information: Before installing, consult
installation instructions, packed with product, for current dimensional data.
Note: These cooktops are approved for indoor use only.
40
Long
20
9
4
10-1/2
16
C L
Cabinet Dimensions (in inches)
227⁄16ʺ
(229⁄16ʺ SS)
201⁄2ʺ
22ʺ
297⁄8ʺ
(30ʺ SS)
23⁄16ʺ
(21⁄4ʺ SS)
283⁄4ʺ
PGP989DN/TN
GE Profile™ 30" Downdraft Gas Cooktop
22716ʺ
(22916ʺ SS)
2012ʺ
22ʺ
2978ʺ
(30ʺ SS)
2316ʺ
(214ʺ SS)
2834ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 5" minimum spacing to adjacent side wall is required
Dimensions and Installation Information
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Dimension and installation information are shown in inches.
Listed by Underwriters Laboratories
Specification Revised 4/09
230284
Installing the Ductwork: Use galvanized or aluminum duct in 6” round or 3-1/4” x 10” size, or combination of both. PVC duct
or locally approved piping should be used if installing under a poured concrete slab.
Local building code must be followed in specifying type and schedule of all duct used.
Note: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Always use an appropriate roof or wall cap with damper.
Laundry-type wall caps should never be used. For maximum efficiency use the
shortest and straightest duct run possible, with as few fittings as possible. For satisfactory
performance the duct run should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths (shown in installation instructions) for various duct configurations.
Rear Wall VentingDownward Venting
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8
PGP989DN/TN
GE Profile™ 30" Downdraft Gas Cooktop