GE Profile PGP9830DJ, Profile PGP9830TJ, Profile PGP9830TJWW, Profile PGP9830DJBB Dimensions And Installation Information

DIMENSIONS AND INSTALLATION INFORMATION
Listed by Underwriters Laboratories
PGP9830DJ/TJ
GE Profile™ Series 30" Downdraft Gas Cooktop
For answers to your Mon ogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, vi sit our website at geapplia nces.com or call GE Answer Center® Service, 800.626.2000.
Specif ication Revis ed 4/16
*NOTE: A 5" minimum spacing to adjacent side wall is required Dimension and installation information are shown in inches.
WALL INSTALLATION : Wall installations require 25" countertop depth. When cabinet is flush against the wall, the fan housing can be rotated to the horizontal position for direct venting through rear wall. Make a countertop cutout in the range cabinet according to unit dimensions and installation type. Duct hole is positioned in back of cabinet for through-the­wall ducting.
PENINSULA OR ISLAND INSTALLATION:
For peninsula/islands a minimum 26"countertop depth is suggested. Blower should be in vertical position. Island or peninsula cabinets may require adjustment in cutout depth and/or location within the width dimensions. Duct hole is positioned in bottom of cabinet for island or peninsula installation.
SLAB INSTALLATION: For peninsula or island installation and rear wall ducting, 6" PVC
duct or locally approved piping should be used if installing under a poured concrete slab.
INSTALLATION INFOR MATION: Before installing, consult installation instructions, packed with product, for current dimensional data.
NOTE: These cooktops are approved for indoor use only.
20
9
4
10-1/2
16
C
L
21 7⁄8ʺ
(21
15
16ʺ SS)
201⁄2ʺ
22ʺ
293⁄4ʺ
23⁄16ʺ
(2
1
4ʺ
SS)
283⁄4ʺ
(29
13
16ʺ SS)
21 78ʺ
(21
15
16ʺ SS)
20
1
2ʺ
22ʺ
29
3
4ʺ
2
3
16ʺ
(2
1
4ʺ SS)
2834ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
(29
13
16ʺ SS)
DIMENSIONS AND INSTALLATION INFORMATION
Dimension and installation information are shown in inches.
Listed by Underwriters Laboratories
PGP9830DJ/TJ
GE Profile™ Series 30" Downdraft Gas Cooktop
For answers to your Mon ogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, vi sit our website at geapplia nces.com or call GE Answer Center® Service, 800.626.2000.
Specif ication Revis ed 4/16
INSTALLING THE DUCTWORK: Use galvanized or aluminum duct in 6" round or 3-1/4" x 10" size, or combination of both. PVC duct or locally approved
piping should be used if installing under a poured concrete slab. Local building
code must be followed in specifying type and schedule of all duct used.
NOTE: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Always use an appropriate roof or wall cap with damper.
Laundry-type wall caps should never be used. For maximum efficiency use
the shortest and straightest duct run possible, with as few fittings as possible.
For satisfactory performance the duct run should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths (shown in installation instructions) for various duct configurations.
Rear Wall VentingDownward Venting
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8