GE JT915, Profile JT915BF, Profile JT915CF, Profile JT915WF, Profile JT915WFWW Dimensions And Installation Information

...
R
Listed by Underwriters Laboratories
Dimensions and Installation Information
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
JT915BF/CF/WF
GE Profile™ 30" Built-In Single Oven
Dimension and installation information are shown in inches.
Specification Revised 2/06
220232
KW Rating
240V
3.6
208V
2.7
Breaker Size
240V
20 Amps
208V
20 Amps
A
Allow 1" overlap of oven over top and bottom edges of cutout
B
Allow 11/16"-3/4" for overlap of oven over side edges of cutout
Most 30” Wall Cabinets can be used with this unit.
Note: These ovens are not approved for stackable or side-by-side installations. Cabinets installed adjacent to wall ovens must have an
adhesion spec of at least a 194°F temperature rating.
Electric wall ovens are not approved for installation with a plug and receptacle. They must be hard wired in accordance with installation instructions.
Installation Information: Before installing, consult installation instructions
packed with product for current dimensional data.
C
L
(Must Support 275 LBS.)
2 x 4 or equivalent runners
Suitable bracing to support runners
21-5/8"
over centerline
of cabinet
Cutout width 28-1/2'' MIN. 28-5/8'' MAX.
29-3/4
28-1/4
30
Recommended
cutout location
32-1/2"
from floor
21
Junction box location
Allow minimum of 21'' for clearance to adjacent corners, drawers, walls, or etc.
Conduit
(48-1/2"
long)
5
27-1/4'' MIN. 27-5/16'' MAX. Cutout height
A
B
23-1/2'' MIN. Cutout depth
22'' MIN.
Optional Undercounter Dimensions and Installation Information
Dimension and installation information are shown in inches.
R
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
JT915BF/CF/WF
GE Profile™ 30" Built-In Single Oven
Specification Revised 2/06
220232
Note: 36” ribbon cooktops (excluding JP968) are approved for use over GE 30” single wall ovens only. 30” ribbon cooktops (excluding JP938) are approved for use over GE 30” and GE 27” single wall ovens. Model JP938 can be installed over 27” wall ovens except stainless model JK915 and JK912SF. Refer to cooktop and wall oven installation information packed with products for current dimensional data.
Note: CleanDesign or Sealed Burner Gas
This installation is to achieve minimum gap between bottom of countertop and control panel. For this installation, the bottom trim will not be flush with a typical 4” toe kick
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating.
Installation Information: Before installing, consult installation instructions packed with product for current dimensional data.
Power cord for cooktop
Junction box for oven
Junction box in adjacent cabinet for cooktop hook-up
2 (two) 90°elbows & sufficient pipe to connect in adjacent cabinet
Right cabinet side
3/4" Support
Shut-off
valve
Pressure regulator
1/2" Black
iron pipe
Union
Conduit
(48-1/2" long)
30" built-in
oven
3-1/2" MIN. Free space
4" To 4-1/2"
3-1/4
22
Side View
5-9/16"
Reference dim. for MAX. support height with typical
36" countertop
height
36" Typical Countertop height
Power cord
Reference 5-9/16
30-7/16
Free space
1-1/2" MIN.
1-1/2" Typical countertop
Side View
22
27-5/16" MAX.
Cutout height
27-1/4" MIN.
Junction box(s) for
oven & radiant
cooktop 22" from
floor
Add suitable
filler to match
adjacent cabinets
when needed
to maintain toe
kick alignment
30" Oven W/ Rad. Cktp.
With 36" Gas Cooktop
With 30" CleanDesign or Sealed Burner Gas Cooktop
5
24
25
Gas or electric cooktops may be installed
over this oven. See cooktop installation
instructions for cutout size. See label on
top of oven for approved cooktop models.
Gas (including the pressure regulator) and electrical connections for gas cooktop must be located in an adjacent accessible location. For a 30" gas cooktop, the connections are more conveniently made to the right.
120 Volt Outlet
Gas connection
Junction box location 240/208V
36'' MIN.
4'' To 4-1/2 '' Toe kick allowable
Match toe kick height front and two sides
22'' MIN. above support platform
Top and/or side fillers may be necessary if unit is positioned between existing cabinets
28-1/2'' MIN. 28-5/8'' MAX.
3/4'' Support platform required
23-1/2" MIN. Cutout depth
Allow 11/16'' overlap over side edges of cutout
1-1/2" Countertop
27-1/4'' MIN. 27-5/16'' MAX. Cutout height