![](/html/53/53c6/53c604c646ce97efcfd3aff798823151abb62e8ef050cc93c6e1b5cca282dfb5/bg1.png)
Specification Revised 7/13
240407
Listed by
Underwriters
Laboratories
PSB9120DF
GE Profile™ Series Advantium® 120V - 30 in. Wall Oven
For answers to your Monogram® or GE®
appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Note: Cabinets
installed adjacent
to wall ovens must
have an adhesion
spec of at least a
194°F temperature
rating.
Note: 2" minimum
between cutouts
when installed
above warming
drawer or single
wall oven.
Installation
Information:
Before installing,
consult installation
instructions packed
with product for current
dimensional data.
Advantium wall oven/GE Profile™ Series cooking tower
dimensions and cabinet installation information (in inches)
2x4’s or
equivalent
solid floor
4-3/16"
25-1/8"
Cutout width
Junction
box location
17-1/2"
Cutout height
29-3/4"
19-1/8"
21-1/2"
Back of Control
Conduit
(48-1/2"
long)
B
30"
5" min.from
floor 1" min.
above toekick
A= Allow 1" overlap of oven over bottom edge of cutout, and allow
1-1/4" overlap at top edge of cutout.
B= Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
A
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
23-1/2"
Cutout depth
2x4’s or
equivalent
solid floor
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
4-3/16"
25-1/8"
Cutout width
Junction
box location
17-1/2"
Cutout height
29-3/4"
19-1/8"
21-1/2"
Back of Control
Conduit
(48-1/2"
long)
B
30"
5" min.from
floor 1" min.
above toekick
A= Allow 1" overlap of oven over bottom edge of cutout, and allow
1-1/4" overlap at top edge of cutout.
B= Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
A
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
23-1/2"
Cutout depth
1" Min. above toekick or adjust
to oven installation height
2" MIN between cutouts
2-1/2" MIN between cutouts
recommended—2" MIN required
9-1/4" cutout height
28-1/2" cutout width
Junction box location
A
B
A
B
Construct Solid Bottom
MIN 3/8" Plywood Supported by
2 x 4 or 1 x 2 Runners, all Four Sides.
(Must Support 150 lbs. for Advantium)
(Must Support 200 lbs. for Wall Oven)
4-3/16"
Conduit
(46" long)
Cabinet width
21-1/2"
To back
of Control
19-1/8"
29-3/4"
C
L
2x4’s or
equivalent
solid floor
21-5/8"
over centerline
of cabinet
4-3/16"
25-1/8"
Cutout width
Junction
box location
17-1/2"
Cutout height
29-3/4"
19-1/8"
21-1/2"
Back of Control
Conduit
(48-1/2"
long)
B
30"
5" min.from
floor 1" min.
above toekick
A= Allow 1" overlap of oven over bottom edge of cutout, and allow
1-1/4" overlap at top edge of cutout.
B= Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
A
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
23-1/2"
Cutout depth
Note: Advantium wallovens can be installed below GE/GE Profile Series nondowndraft gas and electric cooktops. It CANNOT be installed below induction or
Monogram (2GU3841385) gas cooktops.
Note: Advantium wall oven comes with two lower trim pieces. One is for use above
36-inch height installations and one is for use below 36-inch installations. Use of
the accessory drawer will replace the bottom trim piece for applicable installations.
Please see installation instructions for full details.
![](/html/53/53c6/53c604c646ce97efcfd3aff798823151abb62e8ef050cc93c6e1b5cca282dfb5/bg2.png)
240407
PSB9120DF
GE Profile™ Series Advantium® 120V - 30 in. Wall Oven
Specification Revised 7/13
Prepare the opening
The Advantium 120V series can be installed in combination with
other GE/Monogram appliances. Always follow each product's
Installation Instructions to compete the installation.
Single Oven Installation:
Order a 30" wide single oven cabinet or cut the opening in a wall
to the dimensions shown.
* For existing cutouts, a maximum width
of 28-1/2" is acceptable. If the opening
is slightly wider, secure a furring strip
on each side of the cutout for securing
the oven.
• Allow 3/4" to 2-1/8" case trim overlap
on the sides and 7/8" overlap on the
bottom of the opening for all models.
The amount of overlap on the sides
depends on the actual cutout width.
Allow 1-1/4" case trim overlap on the
top for models PSB9120 and for models
ZSC1201 and ZSC1202.
• Oven overlaps will conceal cut edges on all sides of the opening.
Note: PSB9120 series Advantium can be installed below GE/GE Profile
non-downdraft gas and electric cooktops. It CANNOT be installed below
induction or Monogram (2GU3841385) gas cooktops.
Note: PSB9120 series Advantium oven comes with two lower trim
pieces. One is for use above 36-inch height installations and one is
for use below 36-inch installations. Use of the accessory drawer will
replace the bottom trim piece for applicable installations. Please see
installation instructions for full details.
Prepare the opening (cont.)
When installed over a single oven or a
warming drawer, allow at least 2" between
the two openings. This separation will
provide clearance for bottom overlap of the
Advantium and the other appliance overlaps.
Construct a solid oven floor of 3/8" min. thick
plywood supported by 2 x 4 or 2 x 2 runners
on all sides.
• the support must be level and rigidly
mounted, flush with the bottom edge of
the cutout.
Note: Additional clearances between the
cutouts may be required. Check to be sure the
oven supports above the Warming Drawer
location do not obstruct the required interior
depth and height. See Warming Drawer
installation instructions for details.
Installation over a GE/Monogram Oven
and Warming Drawer:
Note: Additional clearances between the
cutouts may be required. Check to be sure the
oven supports above the Warming Drawer
location do not obstruct the required interior
depth and height. See Warming Drawer
installation instructions for details.
CAUTION: For personal safety, the mounting
surface must be capable of supporting the
cabinet load, in addition to the added weight
of this approximate 80-pound oven and 30pound drawer, plus additional oven loads of up
to 50 pounds or a total weight of 160 pounds.
Preparation WITH an Accessory Drawer
Installation over a GE/Monogram
Warming Drawer:
30”
23-1/2”
25-1/4”
Min.
21”
2” Min.
(3” recommended)
Per warming
drawer
requirement
Construct
Solid Bottom
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
5” min.
from floor
1” min.
above
toekick
Construct Solid
Bottom Min.
3/8” Plywood
Supported by
2x4 or 2x2
Runners all
Four Sides
30”
23-1/2”
21”
2” Min.
Per Oven
Requirement
Per warming drawer requirement
2” Min.
(3” recommended)
25-1/4”
Min.
5” min.
1” min.
above
toekick
30”
25-1/4”
Min.
21”
Construct
Base
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
5” min.
from floor
1” min.
above
toekick